pyramid) ..
I tried to use the scale component, but it scales the whole building instead of gradually scaling it.
Do you have any thoughts on how to do that?
…
he installation folder, Drag & drop SYNTACTIC(green one) over your grasshopper canvas.3. Close your rhino and reopen it. 4. Type GrasshopperDeveloperSettings5. Tick the Memory load *.GHA assemblies using COFF byte arrays option6. Run grasshopper and enjoy plugin…
NONE, in SIZING:PARAMETERS". I'm not sure of where to start in troubleshooting this. I've attached the file.
Thank you,
See the errors and warnings below:
{0;0;0}
0. Current document units is in Meters
1. Conversion to Meters will be applied = 1.000
2. [1 of 8] Writing simulation parameters...
3. [2 of 8] Writing context surfaces...
4. [2 of 8] Writing context surfaces...
5. [3 of 8] Writing geometry...
6. [4 of 8] Writing Electric Load Center - Generator specifications ...
7. [5 of 8] Writing materials and constructions...
8. [6 of 8] Writing schedules...
9. [7 of 8] Writing loads and ideal air system...
10. [8 of 8] Writing outputs...
11. ...
... idf file is successfully written to : R:\Green\SuRG\Building_Performance_Analysis\2016_analysis_studies\Energy_Analysis_Comparison\Honeybee_+_Ladybug\tutorial01\EnergyPlus\tutorial01.idf
12.
13. Analysis is running!...
14. ...
...
Done! Read below for errors and warnings:
15.
16. Program Version,EnergyPlus, Version 8.5.0-c87e61b44b, YMD=2016.10.31 11:39,IDD_Version 8.5.0
17.
18. ************* IDF Context for following error/warning message:
19.
20. ************* Note -- lines truncated at 300 characters, if necessary...
21.
22. ************* 24 Sizing:Parameters,
23.
24. ************* Only last 1 lines before error line shown.....
25.
26. ************* 25 None, !- Heating Sizing Factor
27.
28. ** Severe ** IP: IDF line~25 Invalid Number in Numeric Field#1 (Heating Sizing Factor), value=NONE, in SIZING:PARAMETERS
29.
30. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.
31.
32. ** ~~~ ** Possible Invalid Numerics or other problems
33.
34. ** Fatal ** IP: Errors occurred on processing IDF file. Preceding condition(s) cause termination.
35.
36. ...Summary of Errors that led to program termination:
37.
38. ..... Reference severe error count=1
39.
40. ..... Last severe error=IP: IDF line~
, value=NONE, in SIZING:PARAMETERS
41.
42. ************* Warning: Node connection errors not checked - most system input has not been read (see previous warning).
43.
44. ************* Fatal error -- final processing. Program exited before simulations began. See previous error messages.
45.
46. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.
47.
48. ************* EnergyPlus Sizing Error Summary. During Sizing: 0 Warning; 0 Severe Errors.
49.
50. ************* EnergyPlus Terminated--Fatal Error Detected. 1 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 9.34sec
51.…
which doesn't exist in the actual problem spec. If galapagos is allowed to change the column position in all possible directions, it is less likely to get stuck in some local optimum.
Let's assume that (all other things being equal) column 20 would yield the best possible answer. The current state of the system though is at column 26, which is pretty good too, just not as good. Galapagos is more likely to 'mutate' the state a little bit instead of a lot, so it'll explore the columns near 26. However 20 isn't near 26 at all, only 25 and 27 are nearby, and maybe 24 and 28. But they'll all worse answers, so after sampling in those directions GP will abandon that as fruitless.
If however you specify the columns using two variables, then the columns near 26 are 20, 25, 27 and 32. That's a far richer space to explore which much better approximates the real problem.…
eone would know how to group each data position from each branch ... meaning, for instance, that I have a list of data with 3 branches, each branch containing 28 data instances (see attached image). Now, how would I get the (0;0)+(1;0)+(2;0) to be grouped in a new branch, as well as (0;1)+(1;1)+(2;1) and so on?
Also, I need for the setup to able to take in variables, so that the 3 branches might change to 6, and the 28 data instances might to change to anything between 10 and 100.
Thanks in advance,
/Claus
…
e structure systems. It presents an algorithmic process where the initial generative rule is based on the growth of Cellular Automata (CA). Digital Fabrication techniques will be used for prototyping. Theoretical lectures about Cellular Automata, Generative design and fabrication techniques will be presented .
Duration : 21 June. – 28 June. 2013 from 10 am to 6 pm Location : ENCODE Studio Address: 2 Wataneya buildings , 14 May Bridge , Smouha , Floor 1 , Apartment 106 Tel: 03-3823637 Mob: 0100-9879995 Email: encodestudio.mail@gmail.com Website: www.encodestudio.net for more information and registration please fill the following form : https://docs.google.com/forms/d/1FC9-CIDsNuzMkmu3Rubj45_7zTBb6YB3OfYnEA9xOMk/viewform?edit_requested=true Attendance Confirmation email will be sent to confirm availability…