he installation folder, Drag & drop SYNTACTIC(green one) over your grasshopper canvas.3. Close your rhino and reopen it. 4. Type GrasshopperDeveloperSettings5. Tick the Memory load *.GHA assemblies using COFF byte arrays option6. Run grasshopper and enjoy plugin…
he canvas redrawing and the Rhino viewport redrawing take some time as well (on my system 6 ms for the empty Gh canvas and 28 ms for the empty Rhino viewport). No timer can avoid that, to my knowledge. The trampoline computes timing after the solution is complete. This means that one cycle is: solution completed + drawn + user specified interval.
Hope that this helps to get started,
- Giulio________________giulio@mcneel.com…
re.
I can point you to a couple of examples of structures at Expedition that we issued the primary set-out information to the contractor in digital form as a Rhino File. These particular structures necessitated this, trying to document tapered structures without "pure" mathematical setout would have been inefficient and problematic using traditional CAD drawings. You will need to have a close working relationship with the contractor/fabricator. For example, we would issue the entire model due various phases, and we used special line-type names assigned to layers to denote status such as "For Construction", "For Information", etc etc so that this information is clearly defined.
Infinity bridge is a project everyone that was involved in was proud of, http://www.expedition.uk.com/index.php?pid=28 . All the setout of this form found dual arch bridge, that the box girder bifurcated over the centre support and tapered in size along it's length with inclined webs was defined in our Rhino model. Of course we still had to issue traditional 2d plans, elevations and sections (which were primarily exported line work from sectioning in Rhino), as builders don't generally walk around with laptops (and there was 3rd party checking, contract letting etc that don't work so well with digital models).
Also, the Entrance Transfer Structure at 55 Baker Street - http://www.expedition.uk.com/index.php?pid=55 (First photo in sequence) was our first project in communicating to the contractor with Rhino models as primary set-out.
Both of these projects were a success, but you have to be really careful and diligent with the models and the checking of them (not that that is any different to any drawing/model preperation). The slightest error could be quite costly if first detected when the project is on site being assembled.
I can also say, that many of the tools for exchanging (importing and exporting) of structure models that you can try from http://www.geometrygym.com/downloads are being used by quite a few firms around the globe for more typical skeletal steel frame projects. Many of the analysis programs can then be used to transfer the structure directly to BIM like REVIT, and some custom spreadsheet formats allow transfer to/from Digital Project. I can't really say in public the projects these are being used on, but I can say they are renowned designers on quite high profile projects.
Even if the tools are used for coordinating and checking with your Rhino model if you need to redevelop from scratch, they will save you time and effort, and a key aspect of the service of these tools is near immediate support with custom and bespoke aspects that your project demands.
Feel free to get in touch if you wish to discuss this privately, I'm happy to try and help you if you desire.
Cheers,
Jon
The Infinity Foot…
heating? Or cooling?)
What if you have 20C? You need to heat to 24-26?
What if you have 28? Then you cool to 24-26?
Something is missing here ...
Or am i wrong? (In this case i don't understand the logic).
Besides that, you are simulating 3 zones instead of 1. Your conncetions of all the HB_setEPZoneSchedules to the HB_setEPIdealAir is causing this. Messy ... a little bit.
-A.…
be done easier, but later on the geometry will change and therefore this seems the better option. But coming back to the problem
First, there were some problems concerning the zone, although it seems solved still the “runenergysimulation” gives the following warning:
1. The simulation has not run correctly because of this severe error:
** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature
Do one of you know what went wrong? It probably will solve most of it.
Second, “set Zone Thresholds” gives the following warning:
1. Solution exception:global name 'maxHumidity_' is not defined
However, the component is missing the max humidity input on the list, has this to do something with the error?
All the components are up to date.
I hope it will be an easy fix.
Gr Lars
“set Zone Thresholds” runtime error
{0;0;0}0. Runtime error (UnboundNameException): global name 'maxHumidity_' is not defined1. Traceback: line 80, in checkTheInputs, "<string>" line 282, in script
"runenergysimulation” report
{0;0}0. Current document units is in Meters1. Conversion to Meters will be applied = 1.0002. TypeError('Waarde kan niet null zijn.\r\nParameternaam: source',)3. Failed to copy the object. Returning the original objects...This can cause strange behaviour!4. [1 of 8] Writing simulation parameters...5. [2 of 8] No context surfaces...6. [3 of 8] Writing geometry...7. [4 of 8] Writing Electric Load Center - Generator specifications ...8. [5 of 8] Writing materials and constructions...9. [6 of 8] Writing schedules...10. [7 of 8] Writing loads and ideal air system...11. [8 of 8] Writing outputs...12. ...... idf file is successfully written to : c:\ladybug\unnamed\EnergyPlus\unnamed.idf13. 14. Analysis is running!...15. c:\ladybug\unnamed\EnergyPlus\eplusout.csv16. ......
Done! Read below for errors and warnings:
17. 18. Program Version,EnergyPlus, Version 8.3.0-6d97d074ea, YMD=2016.03.02 20:55,IDD_Version 8.3.019. 20. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.21. 22. ************* Beginning Zone Sizing Calculations23. 24. ** Warning ** GetInternalHeatGains: People="CLASSROOMOFFICEPEOPLE", Activity Level Schedule Name values25. 26. ** ~~~ ** fall outside typical range [70,1000] W/person for Thermal Comfort Reporting.27. 28. ** ~~~ ** Odd comfort values may result; Schedule="SCHOCCUPANCYSCHEDULE".29. 30. ** ~~~ ** Entered min/max range=[0.0,1.0] W/person.31. 32. ** Warning ** Calculated design heating load for zone=CLASSROOM is zero.33. 34. ** ~~~ ** Check Sizing:Zone and ZoneControl:Thermostat inputs.35. 36. ** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature37. 38. ** ~~~ ** ...check zone thermostat set point and design supply air temperatures39. 40. ** ~~~ ** ...zone name = CLASSROOM41. 42. ** ~~~ ** ...design sensible cooling load = 25499.10 W43. 44. ** ~~~ ** ...thermostat set point temp = 0.000 C45. 46. ** ~~~ ** ...zone temperature = 15.334 C47. 48. ** ~~~ ** ...supply air temperature = 15.000 C49. 50. ** ~~~ ** ...temperature difference = -0.33433 C51. 52. ** ~~~ ** ...calculated volume flow rate = 197273.21341 m3/s53. 54. ** ~~~ ** ...calculated mass flow rate = 237634.19357 kg/s55. 56. ** Warning ** ManageSizing: For a plant sizing run, there must be at least 1 Sizing:Plant object input. SimulationControl Plant Sizing option ignored.57. 58. ************* Testing Individual Branch Integrity59. 60. ************* All Branches passed integrity testing61. 62. ************* Testing Individual Supply Air Path Integrity63. 64. ************* All Supply Air Paths passed integrity testing65. 66. ************* Testing Individual Return Air Path Integrity67. 68. ************* All Return Air Paths passed integrity testing69. 70. ************* No node connection errors were found.71. 72. ************* Beginning Simulation73. 74. ************* Simulation Error Summary *************75. 76. ** Warning ** The following Report Variables were requested but not generated77. 78. ** ~~~ ** because IDF did not contain these elements or misspelled variable name -- check .rdd file79. 80. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL COOLING ENERGY, Frequency=Hourly81. 82. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL HEATING ENERGY, Frequency=Hourly83. 84. ************* Key=*, VarName=CHILLER ELECTRIC ENERGY, Frequency=Hourly85. 86. ************* Key=*, VarName=BOILER HEATING ENERGY, Frequency=Hourly87. 88. ************* Key=*, VarName=FAN ELECTRIC ENERGY, Frequency=Hourly89. 90. ************* Key=*, VarName=ZONE VENTILATION FAN ELECTRIC ENERGY, Frequency=Hourly91. 92. ************* Key=*, VarName=EARTH TUBE FAN ELECTRIC ENERGY, Frequency=Hourly93. 94. ************* Key=*, VarName=PUMP ELECTRIC ENERGY, Frequency=Hourly95. 96. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT LOSS ENERGY, Frequency=Hourly97. 98. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT GAIN ENERGY, Frequency=Hourly99. 100. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE COOLING ENERGY, Frequency=Hourly101. 102. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE HEATING ENERGY, Frequency=Hourly103. 104. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.105. 106. ************* EnergyPlus Sizing Error Summary. During Sizing: 3 Warning; 1 Severe Errors.107. 108. ************* EnergyPlus Completed Successfully-- 5 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 4.65sec109.…
ts phase changing properties, as a spatial material without a traditional framework or support material creates the ability to navigate and fabricate directly on and around existing objects.
Use of 3D vector-based tool paths and a robotic arm forced the students to rethink their design strategy through the exploration of the relationship between material and tooling. Custom tools and techniques were developed through the workshop in order to work with this novel material. The following work produced during this 10-day workshop from students of Tamkang University, ChiaoTung University, Feng Chia University examine this approach....
Tutors
Ursula Frick University Innsbruck | [uto] | Austria
Thomas Grabner University Innsbruck | [uto] | Austria
Shih-Yuan Wang Swiss Federal Institute of Technology (EPFL)
Tsung-Hsien Wang Sheffield University | United Kingdom
Additive Robotic Materialization is an experimental research project in cooperation with Cheng Yang Product Design Co. Ltd (澄洋產品設計 佘昱錫) sponsored by Tamkang University Department of Architecture Prof. Chen-Cheng Chen (淡江大學建築系 陳珍誠教授) and ABB Taiwan.
special thanks to HAL - Thibault Schwartz for the educational license for this 10days workshop.
Music: 'Emergence' by Trifonic.…
this common installation problem please find a tested remedy shared by one of the group members:
Comment by Iman Sheikhansari on August 26, 2019 at 8:33amDelete Comment
HiIf you are encountering a problem with rhino 6 versions don't worryFollow these steps.1. Download SYNTACTIC from https://sites.google.com/site/pirouznourian/syntactic-design2. Install it and go to the installation folder, Drag & drop SYNTACTIC(green one) over your grasshopper canvas.3. Close your rhino and reopen it. 4. Type GrasshopperDeveloperSettings5. Tick the Memory load *.GHA assemblies using COFF byte arrays option6. Run grasshopper and enjoy plugin
I hope this helps,
Best regards,
Pirouz
…
s than 40% on average.2. 8gb usage is steady at 28% 3. I've been now looking at 2 blank white screen, in both Rhino and Grasshopper for well over 20 min. finally I went for a walk at 10:25am, (its a beautiful day why waste it looking at nonexistent calculations, It would help if there was a timing function in the code that would let me know how long the calculations were going to take, came back 11:25am still no results. Had to Quit Rhino in the Start manager.
I have used all sorts of window programs for well over 25 years. Rhino and Grasshopper are the only 2 programs that I have ever seen that show totally white screens in their operating windows :(
…