ggle A
7. Toggle A
8. Toggle 2
9. Toggle 3
10. Toggle A
11. Toggle A
12. Toggle 3
I was thinking to use somehow slider and animate option....but without luck
Any idea would be appreciated…
Writing simulation parameters...3. [2 of 8] No context surfaces...4. [3 of 8] Writing geometry...5. unsupported operand type(s) for +: 'str' and 'list'6. Failed to write Pelle_aperture000 to idf file7. unsupported operand type(s) for +: 'str' and 'list'8. Failed to write Pelle_aperture001 to idf file9. unsupported operand type(s) for +: 'str' and 'list'10. Failed to write Pelle_aperture002 to idf file11. [4 of 8] Writing Electric Load Center - Generator specifications ...12. [5 of 8] Writing materials and constructions...13. [6 of 8] Writing schedules...14. [7 of 8] Writing loads and ideal air system...15. [8 of 8] Writing outputs...16. ...... idf file is successfully written to : C:\Users\Personal\Desktop\TESI\x001\THOR\EnergyPlus\THOR.idf17. 18. Set runEnergyPlus to True!
or this
0. Current document units is in Meters1. Conversion to Meters will be applied = 1.0002. [1 of 8] Writing simulation parameters...3. [2 of 8] No context surfaces...4. [3 of 8] Writing geometry...5. Runtime error (MissingMemberException): 'hb_EPFenSurface' object has no attribute 'blindsMaterial'6. Traceback:line 1567, in main, "<string>"line 2134, in script
i think that i've same problem with my windows...any suggestion???
Thanks for all…
)
3. KeyError(1417,)
4. KeyError(1417,)
5. KeyError(1417,)
6. KeyError(1417,)
7. KeyError(1417,)
8. KeyError(1417,)
9. KeyError(1417,)
10. KeyError(1417,)
11.......
i tried different weather file but also same result. it seems i have same problem. the file am working on is the radiation file i took from the examples . whats seems to be the problem?
thank you for your time…
is shorthand for [0 to 8].
> 10 Any number larger than X. This notation is shorthand for [11 to infinity].
>= 5 Any number larger than or equal to X. This notation is shorthand for [5 to infinity].
--
David Rutten
david@mcneel.com
Seattle, WA…
Added by David Rutten at 9:27pm on November 3, 2013
ee 3)
{5}
0 15
{6}
0 16
And I want to place points at every possible combination of these coordinates, treating Tree 1 as X coordinates, Tree 2 as Y coordinates, and Tree 3 as Z coordinates. Also, I would like the list of points to be a tree with paths corresponding to the coordinates. Wouldn't it be nice if I could plug these trees into a Point XYZ, with a new "branch cross reference" method, and get the following result?
{0:3:5}
0 {10.0, 13.0, 15.0}
{0:3:6}
0 {10.0, 13.0, 16.0}
{0:4:5}
0 {10.0, 14.0, 15.0}
{0:4:6}
0 {10.0, 14.0, 16.0}
{1:3:5}
0 {11.0, 13.0, 15.0}
{1:3:6}
0 {11.0, 13.0, 16.0}
{1:4:5}
0 {11.0, 14.0, 15.0}
{1:4:6}
0 {11.0, 14.0, 16.0}
{2:3:5}
0 {12.0, 13.0, 15.0}
{2:3:6}
0 {12.0, 13.0, 16.0}
{2:4:5}
0 {12.0, 14.0, 15.0}
{2:4:6}
0 {12.0, 14.0, 16.0}
In this form of cross referencing, every combination of individual branches from the different lists is used as separate input, and the output for each combination is put onto a branch in the result whose path is the concatenation of the input branch paths used.…
Added by Andy Edwards at 7:03pm on November 3, 2009
NONE, in SIZING:PARAMETERS". I'm not sure of where to start in troubleshooting this. I've attached the file.
Thank you,
See the errors and warnings below:
{0;0;0}
0. Current document units is in Meters
1. Conversion to Meters will be applied = 1.000
2. [1 of 8] Writing simulation parameters...
3. [2 of 8] Writing context surfaces...
4. [2 of 8] Writing context surfaces...
5. [3 of 8] Writing geometry...
6. [4 of 8] Writing Electric Load Center - Generator specifications ...
7. [5 of 8] Writing materials and constructions...
8. [6 of 8] Writing schedules...
9. [7 of 8] Writing loads and ideal air system...
10. [8 of 8] Writing outputs...
11. ...
... idf file is successfully written to : R:\Green\SuRG\Building_Performance_Analysis\2016_analysis_studies\Energy_Analysis_Comparison\Honeybee_+_Ladybug\tutorial01\EnergyPlus\tutorial01.idf
12.
13. Analysis is running!...
14. ...
...
Done! Read below for errors and warnings:
15.
16. Program Version,EnergyPlus, Version 8.5.0-c87e61b44b, YMD=2016.10.31 11:39,IDD_Version 8.5.0
17.
18. ************* IDF Context for following error/warning message:
19.
20. ************* Note -- lines truncated at 300 characters, if necessary...
21.
22. ************* 24 Sizing:Parameters,
23.
24. ************* Only last 1 lines before error line shown.....
25.
26. ************* 25 None, !- Heating Sizing Factor
27.
28. ** Severe ** IP: IDF line~25 Invalid Number in Numeric Field#1 (Heating Sizing Factor), value=NONE, in SIZING:PARAMETERS
29.
30. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.
31.
32. ** ~~~ ** Possible Invalid Numerics or other problems
33.
34. ** Fatal ** IP: Errors occurred on processing IDF file. Preceding condition(s) cause termination.
35.
36. ...Summary of Errors that led to program termination:
37.
38. ..... Reference severe error count=1
39.
40. ..... Last severe error=IP: IDF line~
, value=NONE, in SIZING:PARAMETERS
41.
42. ************* Warning: Node connection errors not checked - most system input has not been read (see previous warning).
43.
44. ************* Fatal error -- final processing. Program exited before simulations began. See previous error messages.
45.
46. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.
47.
48. ************* EnergyPlus Sizing Error Summary. During Sizing: 0 Warning; 0 Severe Errors.
49.
50. ************* EnergyPlus Terminated--Fatal Error Detected. 1 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 9.34sec
51.…
etting when I merge the three trees, but what I would like to get is:
essentially a tree with 27 branches, each with a single list of either 11 or 21 points.
{0} (N=11)
{1} (N=11)
...
{10} (N=21)
{11} (N=21)
...
{17} (N=11)
{18) (N=11)
{27} (N=11)
Any help would be greatly appreciated.
All the best,
Matt
…
Added by Matt Schmid at 3:06pm on December 4, 2010
First use a series component with start=1, step=42, count=3
Use the output to create a new series component with start=existingseries, step=1, count=11