These are normal tree manipulations or ways to modify lists.
A way to get started is to read the Grasshopper primer, chapter 8, page 36 to 52.
- Giulio _____________ giulio@mcneel.com McNeel Europe
Hi Danny
Er...indeed you have a strong point...but what about the rest of PLines? - or Pipes if you prefer (8good + 1bad = 9/3 = 3 per peripheral truss).
Looks good, How can I then select those circles as a branch? For example,
I want to divide all the Radius 3 circles into 8 parts, all radius 9 into 6 parts etc.
Many Thanks for your help
olume a factor of x bigger, the scaling factor needs to be x^(1/3) which is the same as the cube-root of x.
In this case we don't just want to make the volume x bigger, we need to get a specific volume, so the first step is to compute x, which is the Target volume divided by the Current volume.…
4, 3, 7, 7, 7, 8
would need to be
5, 6, 7, 8, 4, 3, 7, 8
ideas?
current workaround (kangaroo dupPt component) removes all duplicates from list, tho does maintain order.
thx…
ace. What I am trying to do is then take these indexes and arrange them to fit a grid - so that all shared edges meet up. e.g. Surface 0 shares edges with surfaces 7 and 8, surface 7 shares edges with 19,4, 3, surface 3 shares and edge with 8 etc. What I need to do is graphically represent this in a grid, so that I can map out the uvs and effectively solve the problem of surface seams. Does anyone have a clue how to do this kind of 2d shuffling?…
NONE, in SIZING:PARAMETERS". I'm not sure of where to start in troubleshooting this. I've attached the file.
Thank you,
See the errors and warnings below:
{0;0;0}
0. Current document units is in Meters
1. Conversion to Meters will be applied = 1.000
2. [1 of 8] Writing simulation parameters...
3. [2 of 8] Writing context surfaces...
4. [2 of 8] Writing context surfaces...
5. [3 of 8] Writing geometry...
6. [4 of 8] Writing Electric Load Center - Generator specifications ...
7. [5 of 8] Writing materials and constructions...
8. [6 of 8] Writing schedules...
9. [7 of 8] Writing loads and ideal air system...
10. [8 of 8] Writing outputs...
11. ...
... idf file is successfully written to : R:\Green\SuRG\Building_Performance_Analysis\2016_analysis_studies\Energy_Analysis_Comparison\Honeybee_+_Ladybug\tutorial01\EnergyPlus\tutorial01.idf
12.
13. Analysis is running!...
14. ...
...
Done! Read below for errors and warnings:
15.
16. Program Version,EnergyPlus, Version 8.5.0-c87e61b44b, YMD=2016.10.31 11:39,IDD_Version 8.5.0
17.
18. ************* IDF Context for following error/warning message:
19.
20. ************* Note -- lines truncated at 300 characters, if necessary...
21.
22. ************* 24 Sizing:Parameters,
23.
24. ************* Only last 1 lines before error line shown.....
25.
26. ************* 25 None, !- Heating Sizing Factor
27.
28. ** Severe ** IP: IDF line~25 Invalid Number in Numeric Field#1 (Heating Sizing Factor), value=NONE, in SIZING:PARAMETERS
29.
30. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.
31.
32. ** ~~~ ** Possible Invalid Numerics or other problems
33.
34. ** Fatal ** IP: Errors occurred on processing IDF file. Preceding condition(s) cause termination.
35.
36. ...Summary of Errors that led to program termination:
37.
38. ..... Reference severe error count=1
39.
40. ..... Last severe error=IP: IDF line~
, value=NONE, in SIZING:PARAMETERS
41.
42. ************* Warning: Node connection errors not checked - most system input has not been read (see previous warning).
43.
44. ************* Fatal error -- final processing. Program exited before simulations began. See previous error messages.
45.
46. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.
47.
48. ************* EnergyPlus Sizing Error Summary. During Sizing: 0 Warning; 0 Severe Errors.
49.
50. ************* EnergyPlus Terminated--Fatal Error Detected. 1 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 9.34sec
51.…
etc.
Group 2 - 1, 6, 11, 16, 21 etc.
Group 3 - 2, 7, 12, 17, 22 etc.
Group 4 - 3, 8, 13, 18, 23 etc.
Group 5 - 4, 9, 14, 19, 24 etc. "
except in data, the branches start at 0, so 'group 1' is branch 0
as for the order of your points, that depends on the input prior sorting...
yrs …