be done easier, but later on the geometry will change and therefore this seems the better option. But coming back to the problem
First, there were some problems concerning the zone, although it seems solved still the “runenergysimulation” gives the following warning:
1. The simulation has not run correctly because of this severe error:
** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature
Do one of you know what went wrong? It probably will solve most of it.
Second, “set Zone Thresholds” gives the following warning:
1. Solution exception:global name 'maxHumidity_' is not defined
However, the component is missing the max humidity input on the list, has this to do something with the error?
All the components are up to date.
I hope it will be an easy fix.
Gr Lars
“set Zone Thresholds” runtime error
{0;0;0}0. Runtime error (UnboundNameException): global name 'maxHumidity_' is not defined1. Traceback: line 80, in checkTheInputs, "<string>" line 282, in script
"runenergysimulation” report
{0;0}0. Current document units is in Meters1. Conversion to Meters will be applied = 1.0002. TypeError('Waarde kan niet null zijn.\r\nParameternaam: source',)3. Failed to copy the object. Returning the original objects...This can cause strange behaviour!4. [1 of 8] Writing simulation parameters...5. [2 of 8] No context surfaces...6. [3 of 8] Writing geometry...7. [4 of 8] Writing Electric Load Center - Generator specifications ...8. [5 of 8] Writing materials and constructions...9. [6 of 8] Writing schedules...10. [7 of 8] Writing loads and ideal air system...11. [8 of 8] Writing outputs...12. ...... idf file is successfully written to : c:\ladybug\unnamed\EnergyPlus\unnamed.idf13. 14. Analysis is running!...15. c:\ladybug\unnamed\EnergyPlus\eplusout.csv16. ......
Done! Read below for errors and warnings:
17. 18. Program Version,EnergyPlus, Version 8.3.0-6d97d074ea, YMD=2016.03.02 20:55,IDD_Version 8.3.019. 20. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.21. 22. ************* Beginning Zone Sizing Calculations23. 24. ** Warning ** GetInternalHeatGains: People="CLASSROOMOFFICEPEOPLE", Activity Level Schedule Name values25. 26. ** ~~~ ** fall outside typical range [70,1000] W/person for Thermal Comfort Reporting.27. 28. ** ~~~ ** Odd comfort values may result; Schedule="SCHOCCUPANCYSCHEDULE".29. 30. ** ~~~ ** Entered min/max range=[0.0,1.0] W/person.31. 32. ** Warning ** Calculated design heating load for zone=CLASSROOM is zero.33. 34. ** ~~~ ** Check Sizing:Zone and ZoneControl:Thermostat inputs.35. 36. ** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature37. 38. ** ~~~ ** ...check zone thermostat set point and design supply air temperatures39. 40. ** ~~~ ** ...zone name = CLASSROOM41. 42. ** ~~~ ** ...design sensible cooling load = 25499.10 W43. 44. ** ~~~ ** ...thermostat set point temp = 0.000 C45. 46. ** ~~~ ** ...zone temperature = 15.334 C47. 48. ** ~~~ ** ...supply air temperature = 15.000 C49. 50. ** ~~~ ** ...temperature difference = -0.33433 C51. 52. ** ~~~ ** ...calculated volume flow rate = 197273.21341 m3/s53. 54. ** ~~~ ** ...calculated mass flow rate = 237634.19357 kg/s55. 56. ** Warning ** ManageSizing: For a plant sizing run, there must be at least 1 Sizing:Plant object input. SimulationControl Plant Sizing option ignored.57. 58. ************* Testing Individual Branch Integrity59. 60. ************* All Branches passed integrity testing61. 62. ************* Testing Individual Supply Air Path Integrity63. 64. ************* All Supply Air Paths passed integrity testing65. 66. ************* Testing Individual Return Air Path Integrity67. 68. ************* All Return Air Paths passed integrity testing69. 70. ************* No node connection errors were found.71. 72. ************* Beginning Simulation73. 74. ************* Simulation Error Summary *************75. 76. ** Warning ** The following Report Variables were requested but not generated77. 78. ** ~~~ ** because IDF did not contain these elements or misspelled variable name -- check .rdd file79. 80. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL COOLING ENERGY, Frequency=Hourly81. 82. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL HEATING ENERGY, Frequency=Hourly83. 84. ************* Key=*, VarName=CHILLER ELECTRIC ENERGY, Frequency=Hourly85. 86. ************* Key=*, VarName=BOILER HEATING ENERGY, Frequency=Hourly87. 88. ************* Key=*, VarName=FAN ELECTRIC ENERGY, Frequency=Hourly89. 90. ************* Key=*, VarName=ZONE VENTILATION FAN ELECTRIC ENERGY, Frequency=Hourly91. 92. ************* Key=*, VarName=EARTH TUBE FAN ELECTRIC ENERGY, Frequency=Hourly93. 94. ************* Key=*, VarName=PUMP ELECTRIC ENERGY, Frequency=Hourly95. 96. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT LOSS ENERGY, Frequency=Hourly97. 98. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT GAIN ENERGY, Frequency=Hourly99. 100. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE COOLING ENERGY, Frequency=Hourly101. 102. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE HEATING ENERGY, Frequency=Hourly103. 104. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.105. 106. ************* EnergyPlus Sizing Error Summary. During Sizing: 3 Warning; 1 Severe Errors.107. 108. ************* EnergyPlus Completed Successfully-- 5 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 4.65sec109.…
geode. The faceting system also references the original use of triangulation for mapping three dimensional landscapes.
My question responds to the need to control the edges lengths and angles within the triangles to make the process of construction possible. We are hoping to keep the edges under 28 inches and the minimum angle more than 15 degrees. What would be your suggestion in grasshopper?
Our process for getting the facet was also... the long way.
1. draw curves based on three dimension measurements of interior
2. networks surface the four curves
3. mesh surface
4. triangulate mesh
5. reduce polygons
6. splitmeshedge where necessary to make quadrilaterals triangles once more
Any suggestions?…
Added by Amanda Gann at 8:57pm on December 4, 2013
aph relaxation in 3D and more). There is much more already in our GitHub repos and more to be added. For getting an idea of our future direction check this lecture out. For getting a better understanding of graphs and graph theory watch this lecture and this lecture on a gamified spatial configuration process. Stay tuned for more and do not hesitate to post Python questions in the meantime.
ps. If you are having installation problems, please check the remedy suggested below:
Comment by Iman Sheikhansari on August 26, 2019 at 8:33amDelete Comment
HiIf you are encountering a problem with rhino 6 versions don't worryFollow these steps.1. Download SYNTACTIC from https://sites.google.com/site/pirouznourian/syntactic-design2. Install it and go to the installation folder, Drag & drop SYNTACTIC(green one) over your grasshopper canvas.3. Close your rhino and reopen it. 4. Type GrasshopperDeveloperSettings5. Tick the Memory load *.GHA assemblies using COFF byte arrays option6. Run grasshopper and enjoy plugin
…
: Castellano
Horarios
Básico - miércoles
18.30 - 21.30 h
Avanzado - miércoles
15.00 - 18.00 h
Una vez finalizado el curso, el alumno podrá solicitar un diploma acreditativo del mismo.
Normativa: http://daetsam.aq.upm.es/servicios/cursos/informacion
Información cursos: http://daetsam.aq.upm.es/servicios/cursos/primavera2014
Métodos de pago: http://daetsam.aq.upm.es/noticias/2014/02/16/cursos-primavera-2014-aplicaciones-informaticas-e-idiomas
…
cy of design communication and the control of information-flow are as important as the creativity of ideas. In response to the concurrent digital evolution emerging in the architectural industry world-wide, the Faculty of Architecture at The University of Hong Kong will host a two week intensive summer program named Digital Practice.Led by professors from The University of Hong Kong, as well as invited practitioners with expertise in practice of cutting edge digital techniques, the program offers participants opportunities to experience applications of computational tools during different stages of an architectural project, i.e. concept design, form finding and optimization, delivery, management and communication of design information under the team-based working environment. By learning advanced computational techniques through case studies in the context of Hong Kong, participants are expected to go beyond the conventional perception of technology, considering users and tools as a feedback-based entity instead of a dichotomy. The program, which is taught in English, includes a series of evening lectures related delivered by teaching staff and invited local architects.對於高品質的建築專案,創意之外,專案過程中高效的設計資訊管理和交流成為項目設計深化和實施必不可少的環節。今天,數字化技術不但改變了建築師的繪圖工具,影響了設計的過程,而且提供了工程建造和管理實施的更有效、更高效的手段。針對建築的數位化演進,香港大學建築學院將於2011年暑假期間,在香港大學建築學院舉辦“數位化實踐”國際研習班。在香港大學建築學院教授及有著相關豐富經驗的外聘實踐建築師的指導下,學員將有機會體驗在專案的不同階段(如概念設計、設計形式的生成、優化,設計資訊的管理和交流),如何有效地應用各種運算智慧化技術(從設計的數位化生成和建築資訊類比到物理模型),提升設計實施的品質,增加設計團隊對於方案的控制。我們將挑戰對於“技術”的傳統認知,即相對於使用者它不僅是工具,更是與使用者互動的媒介,二者形成一個有機的合體。研習班期間會安排系列講座,展現數位化技術在實踐工程中的廣泛應用。…
ectural project, the efficiency of design communication and the control of information-flow are as important as the creativity of ideas. In response to the concurrent digital evolution emerging in the architectural industry world-wide, the Faculty of Architecture at The University of Hong Kong will host a two week intensive summer program named Digital Practice.Led by professors from The University of Hong Kong, as well as invited practitioners with expertise in practice of cutting edge digital techniques, the program offers participants opportunities to experience applications of computational tools during different stages of an architectural project, i.e. concept design, form finding and optimization, delivery, management and communication of design information under the team-based working environment. By learning advanced computational techniques through case studies in the context of Hong Kong, participants are expected to go beyond the conventional perception of technology, considering users and tools as a feedback-based entity instead of a dichotomy. The program, which is taught in English, includes a series of evening lectures related delivered by teaching staff and invited local architects.對於高品質的建築專案,創意之外,專案過程中高效的設計資訊管理和交流成為項目設計深化和實施必不可少的環節。今天,數字化技術不但改變了建築師的繪圖工具,影響了設計的過程,而且提供了工程建造和管理實施的更有效、更高效的手段。針對建築的數位化演進,香港大學建築學院將於2011年暑假期間,在香港大學建築學院舉辦“數位化實踐”國際研習班。在香港大學建築學院教授及有著相關豐富經驗的外聘實踐建築師的指導下,學員將有機會體驗在專案的不同階段(如概念設計、設計形式的生成、優化,設計資訊的管理和交流),如何有效地應用各種運算智慧化技術(從設計的數位化生成和建築資訊類比到物理模型),提升設計實施的品質,增加設計團隊對於方案的控制。我們將挑戰對於“技術”的傳統認知,即相對於使用者它不僅是工具,更是與使用者互動的媒介,二者形成一個有機的合體。研習班期間會安排系列講座,展現數位化技術在實踐工程中的廣泛應用。…
and enhancing its intrinsic qualities.
The program of the workshop consists of an intense exploration of Günther Domenig’s Steinhaus (situated at Ossiachersee in Carinthia, Austria) and it’s visible and hidden properties. By the use of mapping strategies these properties can be isolated and will be implemented as a temporary installation.
Each participant will investigate certain spatial aspects using methods of mapping.
In a series of tutorials on various techniques, strategies will be developed to translate and structure the collected information into a unified spatial concept. Participants will work amongst groups to propose the result of their investigations with a site specific installation which will be digitally materialized on site.
Complementary program:
lecture by Stefan Rutzinger & Kristina Schinegger, soma
guided tour and lecture about Steinhaus and Günther Domenig by Christian Halm
presentation by Clemens Preisinger, karamba
Closing event and presentation
250€ early bird registration (until June 14th) | 300€ (until June 28)
More information at www.semf.cc
Email us at info@SeMF.cc…
[2 of 8] No context surfaces...5. [3 of 8] Writing geometry...6. [4 of 8] Writing Electric Load Center - Generator specifications ...7. [5 of 8] Writing materials and constructions...8. [6 of 8] Writing schedules...9. [7 of 8] Writing loads and ideal air system...10. [8 of 8] Writing outputs...11. ...... idf file is successfully written to : C:\Users\Personal\Desktop\TESI\x006\THOR001\EnergyPlus\THOR001.idf12. 13. Analysis is running!...14. C:\Users\Personal\Desktop\TESI\x006\THOR001\EnergyPlus\eplusout.csv15. ......
Done! Read below for errors and warnings:
16. 17. Program Version,EnergyPlus, Version 8.3.0-6d97d074ea, YMD=2016.01.17 17:56,IDD_Version 8.3.018. 19. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.20. 21. ************* Beginning Zone Sizing Calculations22. 23. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)24. 25. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=00126. 27. ** ~~~ ** because vertex 1 of back surface=PELLE_NORD1 is in front of receiving surface=PELLE_COMUNIONE00128. 29. ** ~~~ ** (Dot Product indicator=184.4593)30. 31. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.32. 33. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)34. 35. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=00136. 37. ** ~~~ ** because vertex 2 of back surface=PELLE_NORD1 is in front of receiving surface=PELLE_COMUNIONE00138. 39. ** ~~~ ** (Dot Product indicator=184.4593)40. 41. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.42. 43. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)44. 45. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=00146. 47. ** ~~~ ** because vertex 3 of back surface=PELLE_NORD1 is in front of receiving surface=PELLE_COMUNIONE00148. 49. ** ~~~ ** (Dot Product indicator=184.4593)50. 51. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.52. 53. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)54. 55. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=00156. 57. ** ~~~ ** because vertex 4 of back surface=PELLE_NORD1 is in front of receiving surface=PELLE_COMUNIONE00158. 59. ** ~~~ ** (Dot Product indicator=184.4593)60. 61. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.62. 63. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)64. 65. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=00166. 67. ** ~~~ ** because vertex 1 of back surface=PELLE_NORD2 is in front of receiving surface=PELLE_COMUNIONE00168. 69. ** ~~~ ** (Dot Product indicator=184.4593)70. 71. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.72. 73. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)74. 75. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=00176. 77. ** ~~~ ** because vertex 2 of back surface=PELLE_NORD2 is in front of receiving surface=PELLE_COMUNIONE00178. 79. ** ~~~ ** (Dot Product indicator=184.4593)80. 81. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.82. 83. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)84. 85. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=00186. 87. ** ~~~ ** because vertex 3 of back surface=PELLE_NORD2 is in front of receiving surface=PELLE_COMUNIONE00188. 89. ** ~~~ ** (Dot Product indicator=184.4593)90. 91. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.92. 93. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)94. 95. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=00196. 97. ** ~~~ ** because vertex 4 of back surface=PELLE_NORD2 is in front of receiving surface=PELLE_COMUNIONE00198. 99. ** ~~~ ** (Dot Product indicator=184.4593)100. 101. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.102. 103. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)104. 105. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001106. 107. ** ~~~ ** because vertex 1 of back surface=PELLE_COMUNIONE002 is in front of receiving surface=PELLE_COMUNIONE001108. 109. ** ~~~ ** (Dot Product indicator=184.4593)110. 111. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.112. 113. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)114. 115. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001116. 117. ** ~~~ ** because vertex 2 of back surface=PELLE_COMUNIONE002 is in front of receiving surface=PELLE_COMUNIONE001118. 119. ** ~~~ ** (Dot Product indicator=184.4593)120. 121. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.122. 123. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)124. 125. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001126. 127. ** ~~~ ** because vertex 1 of back surface=WIN_006_GLZP_0 is in front of receiving surface=PELLE_COMUNIONE001128. 129. ** ~~~ ** (Dot Product indicator=182.6148)130. 131. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.132. 133. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)134. 135. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001136. 137. ** ~~~ ** because vertex 2 of back surface=WIN_006_GLZP_0 is in front of receiving surface=PELLE_COMUNIONE001138. 139. ** ~~~ ** (Dot Product indicator=92.2297)140. 141. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.142. 143. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)144. 145. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001146. 147. ** ~~~ ** because vertex 3 of back surface=WIN_006_GLZP_0 is in front of receiving surface=PELLE_COMUNIONE001148. 149. ** ~~~ ** (Dot Product indicator=92.2297)150. 151. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.152. 153. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)154. 155. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001156. 157. ** ~~~ ** because vertex 1 of back surface=WIN_006_GLZP_1 is in front of receiving surface=PELLE_COMUNIONE001158. 159. ** ~~~ ** (Dot Product indicator=182.6148)160. 161. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.162. 163. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)164. 165. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001166. 167. ** ~~~ ** because vertex 2 of back surface=WIN_006_GLZP_1 is in front of receiving surface=PELLE_COMUNIONE001168. 169. ** ~~~ ** (Dot Product indicator=92.2297)170. 171. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.172. 173. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)174. 175. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001176. 177. ** ~~~ ** because vertex 3 of back surface=WIN_006_GLZP_1 is in front of receiving surface=PELLE_COMUNIONE001178. 179. ** ~~~ ** (Dot Product indicator=182.6148)180. 181. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.182. 183. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)184. 185. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001186. 187. ** ~~~ ** because vertex 1 of back surface=WIN_006_GLZP_2 is in front of receiving surface=PELLE_COMUNIONE001188. 189. ** ~~~ ** (Dot Product indicator=92.2297)190. 191. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.192. 193. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)194. 195. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001196. 197. ** ~~~ ** because vertex 2 of back surface=WIN_006_GLZP_2 is in front of receiving surface=PELLE_COMUNIONE001198. 199. ** ~~~ ** (Dot Product indicator=1.8446)200. 201. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.202. 203. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)204. 205. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001206. 207. ** ~~~ ** because vertex 3 of back surface=WIN_006_GLZP_2 is in front of receiving surface=PELLE_COMUNIONE001208. 209. ** ~~~ ** (Dot Product indicator=1.8446)210. 211. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.212. 213. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)214. 215. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001216. 217. ** ~~~ ** because vertex 1 of back surface=WIN_006_GLZP_3 is in front of receiving surface=PELLE_COMUNIONE001218. 219. ** ~~~ ** (Dot Product indicator=92.2297)220. 221. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.222. 223. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)224. 225. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001226. 227. ** ~~~ ** because vertex 2 of back surface=WIN_006_GLZP_3 is in front of receiving surface=PELLE_COMUNIONE001228. 229. ** ~~~ ** (Dot Product indicator=1.8446)230. 231. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.232. 233. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)234. 235. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001236. 237. ** ~~~ ** because vertex 3 of back surface=WIN_006_GLZP_3 is in front of receiving surface=PELLE_COMUNIONE001238. 239. ** ~~~ ** (Dot Product indicator=92.2297)240. 241. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.242. 243. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)244. 245. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001246. 247. ** ~~~ ** because vertex 3 of back surface=PELLE_COMUNIONE003 is in front of receiving surface=PELLE_COMUNIONE001248. 249. ** ~~~ ** (Dot Product indicator=184.4593)250. 251. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.252. 253. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)254. 255. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001256. 257. ** ~~~ ** because vertex 4 of back surface=PELLE_COMUNIONE003 is in front of receiving surface=PELLE_COMUNIONE001258. 259. ** ~~~ ** (Dot Product indicator=184.4593)260. 261. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.262. 263. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)264. 265. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001266. 267. ** ~~~ ** because vertex 1 of back surface=PELLE_EST is in front of receiving surface=PELLE_COMUNIONE001268. 269. ** ~~~ ** (Dot Product indicator=184.4593)270. 271. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.272. 273. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)274. 275. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001276. 277. ** ~~~ ** because vertex 2 of back surface=PELLE_EST is in front of receiving surface=PELLE_COMUNIONE001278. 279. ** ~~~ ** (Dot Product indicator=184.4593)280. 281. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.282. 283. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)284. 285. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001286. 287. ** ~~~ ** because vertex 1 of back surface=WIN_001_GLZP_0 is in front of receiving surface=PELLE_COMUNIONE001288. 289. ** ~~~ ** (Dot Product indicator=180.7210)290. 291. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.292. 293. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)294. 295. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001296. 297. ** ~~~ ** because vertex 3 of back surface=WIN_001_GLZP_0 is in front of receiving surface=PELLE_COMUNIONE001298. 299. ** ~~~ ** (Dot Product indicator=180.7210)300. 301. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.302. 303. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)304. 305. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001306. 307. ** ~~~ ** because vertex 2 of back surface=WIN_001_GLZP_1 is in front of receiving surface=PELLE_COMUNIONE001308. 309. ** ~~~ ** (Dot Product indicator=180.7210)310. 311. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.312. 313. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)314. 315. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001316. 317. ** ~~~ ** because vertex 3 of back surface=WIN_001_GLZP_2 is in front of receiving surface=PELLE_COMUNIONE001318. 319. ** ~~~ ** (Dot Product indicator=180.7210)320. 321. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.322. 323. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)324. 325. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001326. 327. ** ~~~ ** because vertex 3 of back surface=PELLE_OVEST is in front of receiving surface=PELLE_COMUNIONE001328. 329. ** ~~~ ** (Dot Product indicator=184.4593)330. 331. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.332. 333. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)334. 335. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001336. 337. ** ~~~ ** because vertex 4 of back surface=PELLE_OVEST is in front of receiving surface=PELLE_COMUNIONE001338. 339. ** ~~~ ** (Dot Product indicator=184.4593)340. 341. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.342. 343. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)344. 345. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001346. 347. ** ~~~ ** because vertex 1 of back surface=WIN_002_GLZP_0 is in front of receiving surface=PELLE_COMUNIONE001348. 349. ** ~~~ ** (Dot Product indicator=180.7210)350. 351. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.352. 353. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)354. 355. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001356. 357. ** ~~~ ** because vertex 3 of back surface=WIN_002_GLZP_0 is in front of receiving surface=PELLE_COMUNIONE001358. 359. ** ~~~ ** (Dot Product indicator=180.7210)360. 361. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.362. 363. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)364. 365. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001366. 367. ** ~~~ ** because vertex 2 of back surface=WIN_002_GLZP_1 is in front of receiving surface=PELLE_COMUNIONE001368. 369. ** ~~~ ** (Dot Product indicator=180.7210)370. 371. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.372. 373. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)374. 375. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001376. 377. ** ~~~ ** because vertex 1 of back surface=WIN_002_GLZP_2 is in front of receiving surface=PELLE_COMUNIONE001378. 379. ** ~~~ ** (Dot Product indicator=180.7210)380. 381. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.382. 383. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)384. 385. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001386. 387. ** ~~~ ** because vertex 3 of back surface=PELLE_SOTTO is in front of receiving surface=PELLE_COMUNIONE001388. 389. ** ~~~ ** (Dot Product indicator=184.4593)390. 391. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.392. 393. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)394. 395. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001396. 397. ** ~~~ ** because vertex 4 of back surface=PELLE_SOTTO is in front of receiving surface=PELLE_COMUNIONE001398. 399. ** ~~~ ** (Dot Product indicator=184.4593)400. 401. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.402. 403. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)404. 405. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001406. 407. ** ~~~ ** because vertex 7 of back surface=PELLE_SOTTO is in front of receiving surface=PELLE_COMUNIONE001408. 409. ** ~~~ ** (Dot Product indicator=184.4593)410. 411. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.412. 413. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)414. 415. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001416. 417. ** ~~~ ** because vertex 8 of back surface=PELLE_SOTTO is in front of receiving surface=PELLE_COMUNIONE001418. 419. ** ~~~ ** (Dot Product indicator=184.4593)420. 421. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.422. 423. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)424. 425. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001426. 427. ** ~~~ ** because vertex 1 of back surface=PELLE_SOPRA_DUP is in front of receiving surface=PELLE_COMUNIONE001428. 429. ** ~~~ ** (Dot Product indicator=184.4593)430. 431. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.432. 433. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)434. 435. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001436. 437. ** ~~~ ** because vertex 4 of back surface=PELLE_SOPRA_DUP is in front of receiving surface=PELLE_COMUNIONE001438. 439. ** ~~~ ** (Dot Product indicator=184.4593)440. 441. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.442. 443. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)444. 445. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001446. 447. ** ~~~ ** because vertex 5 of back surface=PELLE_SOPRA_DUP is in front of receiving surface=PELLE_COMUNIONE001448. 449. ** ~~~ ** (Dot Product indicator=184.4593)450. 451. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.452. 453. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)454. 455. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001456. 457. ** ~~~ ** because vertex 8 of back surface=PELLE_SOPRA_DUP is in front of receiving surface=PELLE_COMUNIONE001458. 459. ** ~~~ ** (Dot Product indicator=184.4593)460. 461. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.462. 463. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)464. 465. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001466. 467. ** ~~~ ** because vertex 1 of back surface=PELLE_NORD2 is in front of receiving surface=PELLE_COMUNIONE002468. 469. ** ~~~ ** (Dot Product indicator=167.5695)470. 471. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.472. 473. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)474. 475. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001476. 477. ** ~~~ ** because vertex 2 of back surface=PELLE_NORD2 is in front of receiving surface=PELLE_COMUNIONE002478. 479. ** ~~~ ** (Dot Product indicator=167.5695)480. 481. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.482. 483. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)484. 485. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001486. 487. ** ~~~ ** because vertex 3 of back surface=PELLE_NORD2 is in front of receiving surface=PELLE_COMUNIONE002488. 489. ** ~~~ ** (Dot Product indicator=195.1092)490. 491. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.492. 493. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)494. 495. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001496. 497. ** ~~~ ** because vertex 4 of back surface=PELLE_NORD2 is in front of receiving surface=PELLE_COMUNIONE002498. 499. ** ~~~ ** (Dot Product indicator=195.1092)500. 501. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.502. 503. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)504. 505. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001506. 507. ** ~~~ ** because vertex 3 of back surface=PELLE_COMUNIONE001 is in front of receiving surface=PELLE_COMUNIONE002508. 509. ** ~~~ ** (Dot Product indicator=167.5695)510. 511. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.512. 513. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)514. 515. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001516. 517. ** ~~~ ** because vertex 4 of back surface=PELLE_COMUNIONE001 is in front of receiving surface=PELLE_COMUNIONE002518. 519. ** ~~~ ** (Dot Product indicator=167.5695)520. 521. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.522. 523. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)524. 525. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001526. 527. ** ~~~ ** because vertex 1 of back surface=WIN_005 is in front of receiving surface=PELLE_COMUNIONE002528. 529. ** ~~~ ** (Dot Product indicator=32.0568)530. 531. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.532. 533. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)534. 535. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001536. 537. ** ~~~ ** because vertex 2 of back surface=WIN_005 is in front of receiving surface=PELLE_COMUNIONE002538. 539. ** ~~~ ** (Dot Product indicator=139.1556)540. 541. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.542. 543. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)544. 545. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001546. 547. ** ~~~ ** because vertex 3 of back surface=WIN_005 is in front of receiving surface=PELLE_COMUNIONE002548. 549. ** ~~~ ** (Dot Product indicator=139.1556)550. 551. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.552. 553. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)554. 555. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001556. 557. ** ~~~ ** because vertex 4 of back surface=WIN_005 is in front of receiving surface=PELLE_COMUNIONE002558. 559. ** ~~~ ** (Dot Product indicator=32.0568)560. 561. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.562. 563. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)564. 565. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001566. 567. ** ~~~ ** because vertex 1 of back surface=PELLE_COMUNIONE003 is in front of receiving surface=PELLE_COMUNIONE002568. 569. ** ~~~ ** (Dot Product indicator=167.5695)570. 571. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.572. 573. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)574. 575. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001576. 577. ** ~~~ ** because vertex 2 of back surface=PELLE_COMUNIONE003 is in front of receiving surface=PELLE_COMUNIONE002578. 579. ** ~~~ ** (Dot Product indicator=167.5695)580. 581. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.582. 583. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)584. 585. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001586. 587. ** ~~~ ** because vertex 3 of back surface=PELLE_COMUNIONE003 is in front of receiving surface=PELLE_COMUNIONE002588. 589. ** ~~~ ** (Dot Product indicator=167.5695)590. 591. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.592. 593. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)594. 595. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001596. 597. ** ~~~ ** because vertex 4 of back surface=PELLE_COMUNIONE003 is in front of receiving surface=PELLE_COMUNIONE002598. 599. ** ~~~ ** (Dot Product indicator=167.5695)600. 601. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.602. 603. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)604. 605. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001606. 607. ** ~~~ ** because vertex 1 of back surface=PELLE_EST is in front of receiving surface=PELLE_COMUNIONE002608. 609. ** ~~~ ** (Dot Product indicator=195.1092)610. 611. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.612. 613. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)614. 615. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001616. 617. ** ~~~ ** because vertex 2 of back surface=PELLE_EST is in front of receiving surface=PELLE_COMUNIONE002618. 619. ** ~~~ ** (Dot Product indicator=195.1092)620. 621. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.622. 623. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)624. 625. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001626. 627. ** ~~~ ** because vertex 3 of back surface=PELLE_EST is in front of receiving surface=PELLE_COMUNIONE002628. 629. ** ~~~ ** (Dot Product indicator=195.1092)630. 631. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.632. 633. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)634. 635. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001636. 637. ** ~~~ ** because vertex 4 of back surface=PELLE_EST is in front of receiving surface=PELLE_COMUNIONE002638. 639. ** ~~~ ** (Dot Product indicator=195.1092)640. 641. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.642. 643. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)644. 645. ** ~~~ ** Solar Distribution = FullInteriorExterior will not work in Zone=001646. 647. ** ~~~ ** because vertex 5 of back surface=PELLE_EST is in front of receiving surface=PELLE_COMUNIONE002648. 649. ** ~~~ ** (Dot Product indicator=195.1092)650. 651. ** ~~~ ** Check surface geometry; if OK, use Solar Distribution = FullExterior instead.652. 653. ** Severe ** Problem in interior solar distribution calculation (CHKBKS)654. [...]
thisthe errorthat appen when i lunch E+ with only one zone....what is going on???? …
pen Brep"; I didn't know it worked on flat surfaces. And I think it's only fair to include in your benchmark the considerable time 'SUnion' takes in this example: 21.9 seconds for 121 rings and likely much more with 400 or 1,000+ rings.
Then I noticed the pattern doesn't match. Checked the circles and they are the same. The distance between them, however, is different: 7 instead of 6. When I change that value to 6, the Python fails badly. All the holes and gaps are gone, which destroys the pattern:
I can't do the "two phase" approach on an 11 X 11 grid, but I can do 6 X 6 and 2 X 2 to get a 12 X 12 grid (40 'SUnion' operations) in 28 seconds total. That beats your benchmark of ~37 seconds for an 11 X 11 grid, if you include the 'SUnion' in your code.
…
lysing and assessing sustainable performance of buildings and structures, called sustainability-open. Yes, open-source: that means everybody can use it as much as they want. We hope that this will give designers and engineers to make more sustainable buildings and structures in the future. And you can take a look at our code - to learn or improve it if you like! The framework is still in early stage and doesn't do a lot yet at the moment, so this is your chance to become an early-adopter.(By the way, very soon new components will come out that will early let you do more.)
The framework is linked to Grasshopper and Rhino - as soon as we have a little bit more, we will add some links on this site too.
At the Design Modelling Symposium Berlin (September 28 - October 3)we will host a workshop over the weekend which will show you everything about the framework and its components, our future plans, etc. We will also teach you how to develop your own components. Not everything will be purely related to the framework as we will be doing a lot of .net development related to Rhino/Grasshopper and other parametric applications. If you would like to know more about the framework, take a look at: http://www.sustainability-open.com or follow us on Twitter: @sustainableopenIf you would like to sign up for the workshop in Berlin or would like to know more, go here:https://www.design-modelling-symposium.de/frontend/index.php?folder...Regards,Jeroen…