to stop referencing the input Lat Lon coord. (36, 86) even though there is no major changes in the input around point 15.
In this specific case 15 is the end of a row of points but the list is flattened and the input window shows no difference before or after 15.
What could be causing this to happen?
…
Added by M11S to gHowl at 5:31pm on January 31, 2016
e some questions.
I want to loop with a foreach loop trough a list of points do i have to make a list before or is it possible to use them coming in from a noed i set the access to list?
Also i dont understand why no plane is created. How do i need to feed the points in?
And why is c# expecting open parens in line 88 and 86?
Hope its not to much at once, probably i should try a few less steps to get the problems solved one by one, just hoped it would be easier and sometimes just a parentesis is missing or some format stuff, so maybe it is not so much i really cant say.
If anybody has the time and feels he wants to help it would be nice on the other hand i understand cause of the amount of chaotic questions.
Regards!…
up d'entre vous connaissent pour l'excellent support qu'il a prodigué chez l'éditeur McNeel !
Dates : lundi 9 et mardi 10 décembre 2013
Niveau : Débutant
Pré-requis : non, mais connaissances en langage de programmation ou Grasshopper seront un plus, connaissances en anglais car le cours sera dispensé en langue anglaise.
…
closest point to the very first would be removed from the list, so the initial list reduces from 100 to 98. From the 98 i pick one and search the remaining 97 for the closest. From the remaining 96 i pick again one and search in the 95,...
(The product I want to result is:
having a number of random lines in 3D space, produced by an even number of points as discribed, this shall be the initial springs for a ("selfadjusting") tensegrity. Each one of these lines (later springs in kangaroo) get divided in three areas - that means four points. These four points again are the "attractor points" of neighbor springs, so the strut "knows" where to set the next elastic connection,...the rest I´ll have to figure out)
angelos…
be done easier, but later on the geometry will change and therefore this seems the better option. But coming back to the problem
First, there were some problems concerning the zone, although it seems solved still the “runenergysimulation” gives the following warning:
1. The simulation has not run correctly because of this severe error:
** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature
Do one of you know what went wrong? It probably will solve most of it.
Second, “set Zone Thresholds” gives the following warning:
1. Solution exception:global name 'maxHumidity_' is not defined
However, the component is missing the max humidity input on the list, has this to do something with the error?
All the components are up to date.
I hope it will be an easy fix.
Gr Lars
“set Zone Thresholds” runtime error
{0;0;0}0. Runtime error (UnboundNameException): global name 'maxHumidity_' is not defined1. Traceback: line 80, in checkTheInputs, "<string>" line 282, in script
"runenergysimulation” report
{0;0}0. Current document units is in Meters1. Conversion to Meters will be applied = 1.0002. TypeError('Waarde kan niet null zijn.\r\nParameternaam: source',)3. Failed to copy the object. Returning the original objects...This can cause strange behaviour!4. [1 of 8] Writing simulation parameters...5. [2 of 8] No context surfaces...6. [3 of 8] Writing geometry...7. [4 of 8] Writing Electric Load Center - Generator specifications ...8. [5 of 8] Writing materials and constructions...9. [6 of 8] Writing schedules...10. [7 of 8] Writing loads and ideal air system...11. [8 of 8] Writing outputs...12. ...... idf file is successfully written to : c:\ladybug\unnamed\EnergyPlus\unnamed.idf13. 14. Analysis is running!...15. c:\ladybug\unnamed\EnergyPlus\eplusout.csv16. ......
Done! Read below for errors and warnings:
17. 18. Program Version,EnergyPlus, Version 8.3.0-6d97d074ea, YMD=2016.03.02 20:55,IDD_Version 8.3.019. 20. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.21. 22. ************* Beginning Zone Sizing Calculations23. 24. ** Warning ** GetInternalHeatGains: People="CLASSROOMOFFICEPEOPLE", Activity Level Schedule Name values25. 26. ** ~~~ ** fall outside typical range [70,1000] W/person for Thermal Comfort Reporting.27. 28. ** ~~~ ** Odd comfort values may result; Schedule="SCHOCCUPANCYSCHEDULE".29. 30. ** ~~~ ** Entered min/max range=[0.0,1.0] W/person.31. 32. ** Warning ** Calculated design heating load for zone=CLASSROOM is zero.33. 34. ** ~~~ ** Check Sizing:Zone and ZoneControl:Thermostat inputs.35. 36. ** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature37. 38. ** ~~~ ** ...check zone thermostat set point and design supply air temperatures39. 40. ** ~~~ ** ...zone name = CLASSROOM41. 42. ** ~~~ ** ...design sensible cooling load = 25499.10 W43. 44. ** ~~~ ** ...thermostat set point temp = 0.000 C45. 46. ** ~~~ ** ...zone temperature = 15.334 C47. 48. ** ~~~ ** ...supply air temperature = 15.000 C49. 50. ** ~~~ ** ...temperature difference = -0.33433 C51. 52. ** ~~~ ** ...calculated volume flow rate = 197273.21341 m3/s53. 54. ** ~~~ ** ...calculated mass flow rate = 237634.19357 kg/s55. 56. ** Warning ** ManageSizing: For a plant sizing run, there must be at least 1 Sizing:Plant object input. SimulationControl Plant Sizing option ignored.57. 58. ************* Testing Individual Branch Integrity59. 60. ************* All Branches passed integrity testing61. 62. ************* Testing Individual Supply Air Path Integrity63. 64. ************* All Supply Air Paths passed integrity testing65. 66. ************* Testing Individual Return Air Path Integrity67. 68. ************* All Return Air Paths passed integrity testing69. 70. ************* No node connection errors were found.71. 72. ************* Beginning Simulation73. 74. ************* Simulation Error Summary *************75. 76. ** Warning ** The following Report Variables were requested but not generated77. 78. ** ~~~ ** because IDF did not contain these elements or misspelled variable name -- check .rdd file79. 80. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL COOLING ENERGY, Frequency=Hourly81. 82. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL HEATING ENERGY, Frequency=Hourly83. 84. ************* Key=*, VarName=CHILLER ELECTRIC ENERGY, Frequency=Hourly85. 86. ************* Key=*, VarName=BOILER HEATING ENERGY, Frequency=Hourly87. 88. ************* Key=*, VarName=FAN ELECTRIC ENERGY, Frequency=Hourly89. 90. ************* Key=*, VarName=ZONE VENTILATION FAN ELECTRIC ENERGY, Frequency=Hourly91. 92. ************* Key=*, VarName=EARTH TUBE FAN ELECTRIC ENERGY, Frequency=Hourly93. 94. ************* Key=*, VarName=PUMP ELECTRIC ENERGY, Frequency=Hourly95. 96. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT LOSS ENERGY, Frequency=Hourly97. 98. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT GAIN ENERGY, Frequency=Hourly99. 100. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE COOLING ENERGY, Frequency=Hourly101. 102. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE HEATING ENERGY, Frequency=Hourly103. 104. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.105. 106. ************* EnergyPlus Sizing Error Summary. During Sizing: 3 Warning; 1 Severe Errors.107. 108. ************* EnergyPlus Completed Successfully-- 5 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 4.65sec109.…
omplete images into the gallery. Exact number of characters is 32023. Can this be larger? In this one sequence I have 1805 images.
Also because they are frames of an animation I would like to be able to view them faster than 1 fps. I know that if I was processing data from them that the speed would be dependent on GH processing time, but it would be nice to preview much faster without having to leave GH.
EDIT: If I could use relative filepaths the list could be longer as there are only 22 Chars in the name and they are stored in the same file as the definition. = 1455 images
…
rasshopper and reinstall it every time because I've seen this problem before in forums but no one ever came up with a fix. Edit:Another weird leak is when I close rhino and grasshopper now even that I had stable low memory usage before closing. Process Rhino.exe is till running and climbing in memory and reached 97% even the program is shut down.Edit2: My gut feeling is that when a component reaches certain branch/item number it starts leaking memory. And specifically recent file/ MRU list is doing the leak…
0%3ATopic%3A160646&page=1#comments
I was trying to update the old VB component to my new 0.9.0006 GH release, copying and pasting, but as I'm new in this scripting world I'm unable to solve the error bounced at the line 97 when I link the surface component.
Any suggestion??
thanks in advance!!
…