EC
1. Between hours 1:00 to 24:002. Current document units is in Meters3. Conversion to Meters will be applied = 1.0004. [1 of 7] Writing simulation parameters...5. [2 of 6] No context surfaces...6. [3 of 6] Writing geometry...7. [4 of 6] Writing materials and constructions...8. [5 of 7] Writing schedules...9. [6 of 7] Writing loads and ideal air system...10. [7 of 7] Writing outputs...11. ...... idf file is successfully written to : c:\ladybug\Freeformtower_IDF\EnergyPlus\Freeformtower_IDF.idf12. 13. Analysis is running!...14. ......
Done! Read below for errors and warnings:
15. 16. Program Version,EnergyPlus-Windows-64 8.1.0.009, YMD=2015.04.04 23:39,IDD_Version 8.1.0.00917. 18. ************* IDF Context for following error/warning message:19. 20. ************* Note -- lines truncated at 300 characters, if necessary...21. 22. ************* 577 Zone,23. 24. ************* Only last 1 lines before error line shown.....25. 26. ************* 578 Freeformbuilding27. 28. ** Warning ** IP: IDF line~578 Comma being inserted after:" Freeformbuilding" in Object=ZONE29. 30. ** Severe ** Out of range value Numeric Field#5 (Type), value=0.00000, range={>=1 and <=1}, in ZONE=FREEFORMBUILDING31. 32. ************* IDF Context for following error/warning message:33. 34. ************* Note -- lines truncated at 300 characters, if necessary...35. 36. ************* 586 BuildingSurface:Detailed,7341.
…
points 0, X-1, (2*x)-1, (3*X)-1, (4*X)-1, (5*X)-1 and then
1, X, (2*x), (3*X), (4*X), (5*X)
2, X+1, (2*x)+1, (3*X)+1, (4*X)+1, (5*X)+1
and so on till
5, X+4, (2*x)+4, (3*X)+4, (4*X)+4, (5*X)+4
How can I do this best?
Thanks,
Niels…
This must be a bug because its true for dividing by all odd numbers:
(i-1)/3
(i-2)/5
(i-3)/7
(i-4)/9
(i-5)/11
....
(i-n)/2n+1
And you can't make it work for even numbers
Added by Danny Boyes at 5:06pm on January 13, 2010
w list should contain a smallest value of the values with the same index. I should keep order of the indexes.
For example, item [21] of the 1st branch = 1, item [21] of the 2nd branch = 2, so item [21] in the resulting list = 1.
Any advise?…
cture, Rhino treats them as a single flat list. For example a surface can have 10 rows and 6 columns of control-points, resulting in a list of 60 points.
But 10 times 6 isn't the only way to get to 60. If you want to make a surface out of a list of 60 points, you'll also have to tell Rhino how those 60 points should be interpreted in terms of a grid. It could be 2*30, 3*20, 4*15, 5*12, 6*10, and all of the aforementioned products the other way around.
Sometimes there's only one way for a number of points to fit into a rectangular grid. For example if you provide 49 points, then 7*7 is the only way to make it work, but these cases are rare so we always demand you give us all the information required to actually make a rectangular grid of control-points from a linear collection.
As for "Why is it, sometimes we need to attach additional value into it?", this is usually because when you divide a domain or a curve into N segments, you end up with N+1 points. For example take the domain {0 to 5}, and divide it into 5 equal subdomains. You end up with {0 to 1}, {1 to 2}, {2 to 3}, {3 to 4} and {4 to 5}. However there are six numbers that mark the transitions between these domains 0, 1, 2, 3, 4 and 5. This is why you often have to add 1 to the UCount, because the number that controls the UCount often results in N+1 actual points.…
Added by David Rutten at 8:30am on December 25, 2014