at your original list of numbers, if I am to go through and check manually to see what I should be getting out, I think you should only get a few outputs (which is why I was confused by all the outputs at the end of the definition.
For example, just as an example I started with X1 as 279 (item index 11). When I did the math, the only indexes that I got were 15,28, and 33.
This is because:
since 279 is positive, look for next number that is at least 180 less or 360 more than X1.
the value of 78 (item index 15) is the first value to satisfy this requirement.
Then, since 78 is smaller than 279, we are looking for the next value at least 180 more or 360 less than 78.
The value 272 (item index 28) is that next value.
Then since 272 is larger than 78, we are looking for the next value at least 180 less or 360 more than 272.
The value 52 (item index 33) is the next value.
So the definition should output the following:
indexes 15, 28, 33.
Does that make sense?…
Added by Brian Harms at 4:20pm on December 10, 2011
e structure systems. It presents an algorithmic process where the initial generative rule is based on the growth of Cellular Automata (CA). Digital Fabrication techniques will be used for prototyping. Theoretical lectures about Cellular Automata, Generative design and fabrication techniques will be presented .
Duration : 21 June. – 28 June. 2013 from 10 am to 6 pm Location : ENCODE Studio Address: 2 Wataneya buildings , 14 May Bridge , Smouha , Floor 1 , Apartment 106 Tel: 03-3823637 Mob: 0100-9879995 Email: encodestudio.mail@gmail.com Website: www.encodestudio.net for more information and registration please fill the following form : https://docs.google.com/forms/d/1FC9-CIDsNuzMkmu3Rubj45_7zTBb6YB3OfYnEA9xOMk/viewform?edit_requested=true Attendance Confirmation email will be sent to confirm availability…
edia and technology. Under the umbrella of MASSv.1.0 Robots and Cyborgs International Workshop and will be supported by a series of lectures. The workshop will integrate the use of a robotic fabrication with Virtual Reality. …
edia and technology. Under the umbrella of MASSv.1.0 Robots and Cyborgs International Workshop and will be supported by a series of lectures. The workshop will integrate the use of a robotic fabrication with Virtual Reality.
…
be done easier, but later on the geometry will change and therefore this seems the better option. But coming back to the problem
First, there were some problems concerning the zone, although it seems solved still the “runenergysimulation” gives the following warning:
1. The simulation has not run correctly because of this severe error:
** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature
Do one of you know what went wrong? It probably will solve most of it.
Second, “set Zone Thresholds” gives the following warning:
1. Solution exception:global name 'maxHumidity_' is not defined
However, the component is missing the max humidity input on the list, has this to do something with the error?
All the components are up to date.
I hope it will be an easy fix.
Gr Lars
“set Zone Thresholds” runtime error
{0;0;0}0. Runtime error (UnboundNameException): global name 'maxHumidity_' is not defined1. Traceback: line 80, in checkTheInputs, "<string>" line 282, in script
"runenergysimulation” report
{0;0}0. Current document units is in Meters1. Conversion to Meters will be applied = 1.0002. TypeError('Waarde kan niet null zijn.\r\nParameternaam: source',)3. Failed to copy the object. Returning the original objects...This can cause strange behaviour!4. [1 of 8] Writing simulation parameters...5. [2 of 8] No context surfaces...6. [3 of 8] Writing geometry...7. [4 of 8] Writing Electric Load Center - Generator specifications ...8. [5 of 8] Writing materials and constructions...9. [6 of 8] Writing schedules...10. [7 of 8] Writing loads and ideal air system...11. [8 of 8] Writing outputs...12. ...... idf file is successfully written to : c:\ladybug\unnamed\EnergyPlus\unnamed.idf13. 14. Analysis is running!...15. c:\ladybug\unnamed\EnergyPlus\eplusout.csv16. ......
Done! Read below for errors and warnings:
17. 18. Program Version,EnergyPlus, Version 8.3.0-6d97d074ea, YMD=2016.03.02 20:55,IDD_Version 8.3.019. 20. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.21. 22. ************* Beginning Zone Sizing Calculations23. 24. ** Warning ** GetInternalHeatGains: People="CLASSROOMOFFICEPEOPLE", Activity Level Schedule Name values25. 26. ** ~~~ ** fall outside typical range [70,1000] W/person for Thermal Comfort Reporting.27. 28. ** ~~~ ** Odd comfort values may result; Schedule="SCHOCCUPANCYSCHEDULE".29. 30. ** ~~~ ** Entered min/max range=[0.0,1.0] W/person.31. 32. ** Warning ** Calculated design heating load for zone=CLASSROOM is zero.33. 34. ** ~~~ ** Check Sizing:Zone and ZoneControl:Thermostat inputs.35. 36. ** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature37. 38. ** ~~~ ** ...check zone thermostat set point and design supply air temperatures39. 40. ** ~~~ ** ...zone name = CLASSROOM41. 42. ** ~~~ ** ...design sensible cooling load = 25499.10 W43. 44. ** ~~~ ** ...thermostat set point temp = 0.000 C45. 46. ** ~~~ ** ...zone temperature = 15.334 C47. 48. ** ~~~ ** ...supply air temperature = 15.000 C49. 50. ** ~~~ ** ...temperature difference = -0.33433 C51. 52. ** ~~~ ** ...calculated volume flow rate = 197273.21341 m3/s53. 54. ** ~~~ ** ...calculated mass flow rate = 237634.19357 kg/s55. 56. ** Warning ** ManageSizing: For a plant sizing run, there must be at least 1 Sizing:Plant object input. SimulationControl Plant Sizing option ignored.57. 58. ************* Testing Individual Branch Integrity59. 60. ************* All Branches passed integrity testing61. 62. ************* Testing Individual Supply Air Path Integrity63. 64. ************* All Supply Air Paths passed integrity testing65. 66. ************* Testing Individual Return Air Path Integrity67. 68. ************* All Return Air Paths passed integrity testing69. 70. ************* No node connection errors were found.71. 72. ************* Beginning Simulation73. 74. ************* Simulation Error Summary *************75. 76. ** Warning ** The following Report Variables were requested but not generated77. 78. ** ~~~ ** because IDF did not contain these elements or misspelled variable name -- check .rdd file79. 80. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL COOLING ENERGY, Frequency=Hourly81. 82. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL HEATING ENERGY, Frequency=Hourly83. 84. ************* Key=*, VarName=CHILLER ELECTRIC ENERGY, Frequency=Hourly85. 86. ************* Key=*, VarName=BOILER HEATING ENERGY, Frequency=Hourly87. 88. ************* Key=*, VarName=FAN ELECTRIC ENERGY, Frequency=Hourly89. 90. ************* Key=*, VarName=ZONE VENTILATION FAN ELECTRIC ENERGY, Frequency=Hourly91. 92. ************* Key=*, VarName=EARTH TUBE FAN ELECTRIC ENERGY, Frequency=Hourly93. 94. ************* Key=*, VarName=PUMP ELECTRIC ENERGY, Frequency=Hourly95. 96. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT LOSS ENERGY, Frequency=Hourly97. 98. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT GAIN ENERGY, Frequency=Hourly99. 100. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE COOLING ENERGY, Frequency=Hourly101. 102. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE HEATING ENERGY, Frequency=Hourly103. 104. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.105. 106. ************* EnergyPlus Sizing Error Summary. During Sizing: 3 Warning; 1 Severe Errors.107. 108. ************* EnergyPlus Completed Successfully-- 5 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 4.65sec109.…
another comma separated txt file. I know how to import points (function Import coordinates), but I dont know how to connect them by lines if the only information I have about lines is the list of point numbers which should be connected. The txt file with point coordinates looks like:
-18,-36,-1000-18,-34,-19.728-18,-32,-17.603-18,-30,-15.372-18,-28,-13.121
...
And the txt file with line connections looks like:
1,22,33,44,55,6
...
Which means that I want to connect point 1 with point 2, point 2 with point 3 etc...
Both txt files are attached, thank you for the answer...…
l equations that describe his attractor in a chaotic behavior when rho > 24.7. All the values of X =sigma(Y-X) *dt never repeat themselves through each moment in time making their distribution totaly random, we can see this at the end of the video with the linear graph. The beautiful thing is that even though the values of X are randomly distribuited over time, the result is a beautiful ordered shape, this in essence is the principal of chaotic systems. Or as James Gleick would say " chaotic systems embed hidden ordering principles"
X =sigma(Y-X)
Y= -X*Z+rho*X-Y
Z = X*Y-betta*Z
X = dx/dt -------> change of X over time
Y = dy/dt -------> change of Y over time
Z= dz/dt -------> change of z over time
rho = 28
betta = 3/8
sigma = 10
http://mathworld.wolfram.com/LorenzAttractor.html…