eone would know how to group each data position from each branch ... meaning, for instance, that I have a list of data with 3 branches, each branch containing 28 data instances (see attached image). Now, how would I get the (0;0)+(1;0)+(2;0) to be grouped in a new branch, as well as (0;1)+(1;1)+(2;1) and so on?
Also, I need for the setup to able to take in variables, so that the 3 branches might change to 6, and the 28 data instances might to change to anything between 10 and 100.
Thanks in advance,
/Claus
…
e structure systems. It presents an algorithmic process where the initial generative rule is based on the growth of Cellular Automata (CA). Digital Fabrication techniques will be used for prototyping. Theoretical lectures about Cellular Automata, Generative design and fabrication techniques will be presented .
Duration : 21 June. – 28 June. 2013 from 10 am to 6 pm Location : ENCODE Studio Address: 2 Wataneya buildings , 14 May Bridge , Smouha , Floor 1 , Apartment 106 Tel: 03-3823637 Mob: 0100-9879995 Email: encodestudio.mail@gmail.com Website: www.encodestudio.net for more information and registration please fill the following form : https://docs.google.com/forms/d/1FC9-CIDsNuzMkmu3Rubj45_7zTBb6YB3OfYnEA9xOMk/viewform?edit_requested=true Attendance Confirmation email will be sent to confirm availability…
Mmm really nice post. Usually light electronic Trip Hop, or spanish Hip-Hop.
Portishead
Radiohead
Massive Attack
Propellerhead
SFDK
Juaninacka
Tote King
Best Regards ;)
es, and these sum up to ~7100. I shall see if I can post a screenshot of everything.
I have no idea how to script that, sorry. But maybe could be a more optimized workflow - just feed one object B at a time, maybe that makes the math behind it more relaxed.
I should emphasize that it is not about 'fault' in the operation, and rather a very slow calculation - the difference does eventually get calculated with no errors whatsoever, the only problem is the unbelievably inefficient, or unproductive time it takes to do so. I think the problem could be the proportion of the objects, one very large, and one very small (28 / 6 / .1cm vs. .05cm), maybe that does something funky to the bounding box calls, I have no idea. And one other thing I suspect is the number of faces in the object, as I progress to let's say 700 cuts, I have then created 700*4 new faces in the object. I don't know if this is indeed something of concern. …
Added by DumDaDaDum at 7:03am on September 29, 2011
o retrieve the first one: (0;0), (0;1) ... (0;4), I put 0 in Path and the TreeBranch turns red. What am I doing wrong?
I would really appreciate some help!
Thankyou!…
Added by Tina Jerrera at 8:09am on November 25, 2016
NONE, in SIZING:PARAMETERS". I'm not sure of where to start in troubleshooting this. I've attached the file.
Thank you,
See the errors and warnings below:
{0;0;0}
0. Current document units is in Meters
1. Conversion to Meters will be applied = 1.000
2. [1 of 8] Writing simulation parameters...
3. [2 of 8] Writing context surfaces...
4. [2 of 8] Writing context surfaces...
5. [3 of 8] Writing geometry...
6. [4 of 8] Writing Electric Load Center - Generator specifications ...
7. [5 of 8] Writing materials and constructions...
8. [6 of 8] Writing schedules...
9. [7 of 8] Writing loads and ideal air system...
10. [8 of 8] Writing outputs...
11. ...
... idf file is successfully written to : R:\Green\SuRG\Building_Performance_Analysis\2016_analysis_studies\Energy_Analysis_Comparison\Honeybee_+_Ladybug\tutorial01\EnergyPlus\tutorial01.idf
12.
13. Analysis is running!...
14. ...
...
Done! Read below for errors and warnings:
15.
16. Program Version,EnergyPlus, Version 8.5.0-c87e61b44b, YMD=2016.10.31 11:39,IDD_Version 8.5.0
17.
18. ************* IDF Context for following error/warning message:
19.
20. ************* Note -- lines truncated at 300 characters, if necessary...
21.
22. ************* 24 Sizing:Parameters,
23.
24. ************* Only last 1 lines before error line shown.....
25.
26. ************* 25 None, !- Heating Sizing Factor
27.
28. ** Severe ** IP: IDF line~25 Invalid Number in Numeric Field#1 (Heating Sizing Factor), value=NONE, in SIZING:PARAMETERS
29.
30. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.
31.
32. ** ~~~ ** Possible Invalid Numerics or other problems
33.
34. ** Fatal ** IP: Errors occurred on processing IDF file. Preceding condition(s) cause termination.
35.
36. ...Summary of Errors that led to program termination:
37.
38. ..... Reference severe error count=1
39.
40. ..... Last severe error=IP: IDF line~
, value=NONE, in SIZING:PARAMETERS
41.
42. ************* Warning: Node connection errors not checked - most system input has not been read (see previous warning).
43.
44. ************* Fatal error -- final processing. Program exited before simulations began. See previous error messages.
45.
46. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.
47.
48. ************* EnergyPlus Sizing Error Summary. During Sizing: 0 Warning; 0 Severe Errors.
49.
50. ************* EnergyPlus Terminated--Fatal Error Detected. 1 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 9.34sec
51.…