. From the Thermal Comfort Indices component, Comfort Index 11 (TCI-11):MRT = f(Ta, Tground, Rprim, e)
with:- Ta = DryBulbTemperature coming from ImportEPW component- Tground = f(Ta, N) where N comes from totalSkyCover input. Tground influences the long-wave radiation emitted by the ground in the MRT calculation.- Rprim defined as solar radiation absorbed by nude man = f(Kglob, hS1, ac)- ac is the clothingAlbedo in % (bodyCharacteristics input)- I can't find any definition in the code of Kglob and hS1. Could you tell me please what are those values referencered to? --> probably the globalHorizontalRadiation but how?- e = vapour pressure calculated from Ta and Relative Humidity input
Do you agree that in this case the MRT does not depend on these inputs: location, meanRadiantTemperature, dewPointTemperature and wind speed?It does not depend neither on the other bodyCharacteristics like bodyPosture, age, sex, met, activityDuration...?
MRT calculated by the TCI-11 method is the mean radiant temperature of a vector pointing vertically with a sky view factor of 100%?For ParisOrly epw,
2. From the SolarAdjustedTemperature component (that seems to be more used for the UTCI calculation examples on Hydra compared to TCI-11).
In contrast to the TCI-11, this component distinguishes diffuse and direct radiation and contextualizes the calculation thanks to _ContextShading input, right? It can also be applied to a mannequin thanks to the CumSkyMatrix and thus evaluate the dishomogeneity of radiation exposure.This component seems not to consider the influence of vapour pressure on the result --> is it then more precise to put the MRT output (from the TCI) as an input of meanRadTemperature for SolarAdjustedTemperature?The default groundReflectivity is set to 0.25 --> is GroundReflectivity taken into account in the Tground or MRT calculation in the TCI component? If yes, what is the hypothesised groundReflectivity?The default clothing albedo of 37% (TCI-11 bodyCharacteristics) corresponds to Clothing Absorptivity of 63%?
If the CumSkyMatrix input is not supplied, I get 9 results for the mannequin --> where are those points/results coming from?
If the CumSkyMatrix input is supplied,I suppose the calculation of the 482 results correspond to a calculation method similar to the radiation analysis component that is averaged over the analysis period. Right?But I don't understand why the mannequin is composed of 481 faces and meshFaceResult gives 482 results.
Finally, what is the link between the MESH results, the solarAdjustedMRT and the Effective Radiant field ? Is there a paper to have a detailed explanation of the method?
3. Here are some results for the ParisOrly energyplus weather data. You can find here attached the grasshopper definition.There is no shading in this simulation and the result coming from the ThermalComfort indices for MRT is very different compared to the solar adjusted MRT.Why such a big difference and which of the result should be plugged into the UTCI calculation component?
Results for ParisOrly.epwM,D,H:1,1,12
Ta : 6.5°Crh: 100%globalHorizontalRadiation: 54 Wh/m2totalSkyCover: 10MRT (TCI-11): 1.2°C
_CumSkyMtxOrDirNormRad = directNormalRadiation : 0 Wh/m2diffuseHorizontalRad: 54 Wh/m2_meanRadTemp = TasolarAdjustedMRT: 10.64°CMRTDelta: 4.14°C
_CumSkyMtxOrDirNormRad = CumulativeSkyMtxdiffuseHorizontalRad: 54 Wh/m2_meanRadTemp = TasolarAdjustedMRT: 10.47°CMRTDelta: 3.97°C
_CumSkyMtxOrDirNormRad = CumulativeSkyMtxdiffuseHorizontalRad: 54 Wh/m2_meanRadTemp = MRT (TCI-11)solarAdjustedMRT: 5.17°CMRTDelta: 3.97°C
Thanks a lot for your helpRegards,
Aymeric
…
Salimzadeh
Assistant: Saeede Kalantari a Fabrication Project for “Structural Systems” BA Course;
Participants: Maryam Ahmadi, Amir Ansaripour, Kimia Bagheri, Mohammad Hassan Habibi, Mohammad Mehdi Zamani, Sam Sabzevari, Zeynab Seyed Zehtab, Mohammad Mehdi Shahroudi, Niloofar Taheri, Masoumeh Abedini, Pedram Feyzi, Asma Karamouz, Kimia Karbalayi, Hamed Kamalzadeh, Fateme Kianinejhad, Maryam Mohammaddoust, Faeze Motamedian, Romina Mehrbod, Sara Naderi, Yasaman Nejati, Kimia Nourinejhad, Morteza Vaziri, Mehragin Baghi, Sana Motallem, Helpers: Milad Amiri, Soroush Raesi, Mahla Behrouz, Alireza Sheykhlar, Shadi Khaleghi, Mohaddese Taheri, Alireza Mohammadi, Mehrnoush Kia
Photography: Sara Ahmadi, Hasan Habibi
Video production: Shayan Khalilbeigi
Special Thanks To Dr. K. Taghizadeh, Dr. H. Mazaherian, Dr. Y. Eslami and Mr.Aliari
With Support Of: Center Of Excellency In Architecture Technology – CEAT - , Collage of Fine Arts University of #Tehran, ‘Art And 4th Dimension’ Symposium, Iran #Fablab and #Fologram
Rhino/Grasshopper and C# Definitions of form-Finding and Member-generation :
http://bit.ly/2RUKc5i…
nputs to run (please refer to the image)
Currently, here is how I set the data:
protected override void RegisterInputParams(GH_Component.GH_InputParamManager pManager) { //Create default size
double defaultBaySize = 0; pManager.AddTextParameter("LotLib", "Llib", "Lot Library", GH_ParamAccess.tree); pManager.AddCurveParameter("BoundaryCrv", "BC", "Boundary Input", GH_ParamAccess.list); pManager.AddIntegerParameter("Direction", "D", "Direction of gridLines", GH_ParamAccess.item, 0); pManager.AddNumberParameter("CCsize", "S", "Distance from column to column", GH_ParamAccess.item, defaultBaySize); pManager.AddCurveParameter("GridCrv", "GC", "Take in curves input for gridlines", GH_ParamAccess.list);
}
protected override void SolveInstance(IGH_DataAccess DA) {/* Setup */ GH_Structure<GH_String> LotLib = new GH_Structure<GH_String>(); DA.GetDataTree(0, out LotLib); List<Curve> BoundaryCrv = new List<Curve>(); if(!DA.GetDataList(1, BoundaryCrv)) { return; } int Direction = 0; DA.GetData(2, ref Direction); double CCsize = 0; DA.GetData(3, ref CCsize);
List<Curve> GridCrvs = new List<Curve>(); DA.GetDataList(4, GridCrvs); if (!DA.GetDataList(4, GridCrvs)) { return; }}
Is there a way can set data in the way if the component does not receive inputs for BoundaryCrv but only GridCrvs, the BoundaryCrv List will empty.
Thank you very much …
being driven by the wii nunchuck... But, here's my issue. I tried it first by having the output from the listener be a 6-digit number... so, I'm using the (CInt(Val(StoredValue))) command and it's writing out 181130... and I can easily split it up selecting the Left(x,3) or Right(x,3)... I first rant that number through a Format("{0:000000}",x) so that even if one of the accx or accy numbers were a 2-digit number (so my overall number would only have 5-digits)... with this Format function... I'm always assured a 6-digit number. And this method works... except...
If the first group of numbers coming in only has 2-digits... So, lets say the accelerometer read out of the first one (accx) is 89. Let's say the accy read out is 119. So, when I run this through the Format function to make it have at least 6 digits, my number now reads 011989. So, if I were to take the first three numbers on the right, my read out would be 989... which is much higher than my expected (60-180 range that is really coming over the Serial Port)... So, I'm back to where I started... in that I need to figure out a better way to split up the data.
Which brings me to your method. I tried it as well... in fact, I added a comma in the serial readout, so the string coming out of the listener reads 89,119. So, I can use your trick to go look for a delimeter and then read to the left and right a certain number of digits... The problem I still have is that the data going into the function is a string, and thus even if I split the 3 digits to the right of the comma out (so, my output says 119)... it's still a string, and my number parameter is still red. In your picture above, was your original 181 130 a number or a string? My guess is that it was understood as a number, because your number parameters at the end are accepting the value. But, in my case... I'm still stuck with the inability to convert a string to a number... Does this make sense? And are their any other workarounds?…
Added by Andy Payne at 9:42am on September 3, 2009
izes like 0.6m, 0.8m, 0.9m and 1.2m are the most "common": In cases where mechanical floors are a must (hospitals for instance) a 2.4/2.4 is quite handy (habitable/mechanical per floor). You can try 1.8/2.7 as well (floor/habitable) since 1.8 floor thickness can host HVAC and some decent W truss size. Also 1.6/2.4 (floor/habitable) is used in small buildings. NOTE: see next.
3. Don't forget to include corrugated metal height + concrete screed height + raised floors height: for the latter, say, something like 0.3m (modules + adjustable mounts + free space for electric stuff [boxes etc]).
4. As regards exteriors, Laurent Buzon is a close friend of mine. Contact him directly on my behalf:
http://www.buzonuk.com/
http://www.google.gr/url?sa=t&rct=j&q=&esrc=s&sourc...
5. LBS Structural ability and "monolithic" floor behavior (humans don't like vibrating habitable spaces) ARE not the same animal.…
ybee_EnergyPlus Window Shade Generator" component.
3. SolveAdj component has the input to set BC for interior surfaces.
If you want to set them to adiabatic then you can use setToAdiabatic components.
4. For natural ventilation Chris has provided extensive answers including this one.
If the component doesn't work then you need to download the files manually from github and replace the userObjects with the old ones. You have to do it separately for Ladybug and Honeybee which can be painful. Is there anyway to change the firewall settings?
…
i have to rely completely in passive means.
To speed things i'm calculating comfort for Extreme hot/cold week, thinking maybe on typical weeks instead.
The cool week is kind of "right", but the hot (extreme) is giving all night hours 100% comfort. Knowing the climate, there is no way this can be the case. Some of the settings with the european standards give sometimes the right tendency, but still, compared to ASHRAE's the average of % percentage is too high.
Also my assumptions for flexibility of use/clothing/etc is the maximal. I mean, no constrains on this respect ("let's be passive as much as we can").
So right now i have no specific questions, but rather your advice, if any: "What you would do ...?? (I don't like these kind of questions, sorry).
A request, yes, if it is possible to output the set temperature for each hour. For instance, when you give the degFromTargetMtx i'll like to know this target. This is for control, and i think this is important for better understanding this black box.
Any other insights you may have, just shoot.
Not related to the discussion, but if you happened to check the model, we are simulating 2 apartments in the building. The northern one is only one thermal zone. The southern is divided in rooms. I wanted to see how much difference e get between both ways. And there is. No doubt the more detailed modeling looks more reliable. Also if you have some points here, shoot again.
BTW humidity, look at page 32-33 in the AC book. Nicol is clear on the "real" influence of the humidity, arguing it is mostly psychological than real.
Thanks again, and to you too Mauricio.
-A.…