by anything else (like walls, ceiling etc.). So, specifying ambient parameters in the simulation does not serve any purpose.
2. Get rid of source subdivision by setting -ds to 0. This will make Radiance assume that your source is a point source ( which seems to be a valid assumption in your case).
3. Finally, you can cut down the time even more by magnifying the candela value of a single light fixture instead of using the 9 fixtures that you have right now. This is a hack, but will work because that way, even the deterministic part of the calculation will feature only 1 variable instead of 9. You can make this work by increasing the candelaMultiplier of that one source by 9.
I have attached a gh file (which shows the parameters options) as an example. The points I have made above will mostly work for electric lighting only. Daylighting needs different kind of optimization because we are dealing with parallel rays from the sun and not a source with directional distribution like electric lights.
The image below is base-case. Takes the maximum time, using default settings.
This one is with direct-only calculations.
This is the case where a single fixture was used and the candela multiplier was used to magnify it's brightness 9 times. Took the least amount of time....but as you can there is a perceptible difference between this one and the base-case.
…
plication to Rhino.Exe.
3. Press Start.
4. Rhino is opening and I open grasshopper.
5. I add native grasshopper c# component and reference .dll
6. I have an access to static variable.
then what I want to do but I can't:
7. I stop the debugger in visual studio and add one more variable and expect that the library would be updated as is when I compile gh components.
8. But when I press continue and the .dll file is not updated and I do not see any additional variables declared. First I thought ok, maybe it is not visible, but I typed a correct name, but the message says that my dll does not contain this type.
9. Then I tried to reference the .dll again, but nothing happens, same old .dll is referenced.
10. When I close and open rhino it is updated. The whole closing and opening operation is a bit disturbing and I would like to debug it via Visual Studio.
Do you know what I doing wrong?
Is it working like so, because .dll is loaded to memory and not referenced from Hard Drive?…
be done easier, but later on the geometry will change and therefore this seems the better option. But coming back to the problem
First, there were some problems concerning the zone, although it seems solved still the “runenergysimulation” gives the following warning:
1. The simulation has not run correctly because of this severe error:
** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature
Do one of you know what went wrong? It probably will solve most of it.
Second, “set Zone Thresholds” gives the following warning:
1. Solution exception:global name 'maxHumidity_' is not defined
However, the component is missing the max humidity input on the list, has this to do something with the error?
All the components are up to date.
I hope it will be an easy fix.
Gr Lars
“set Zone Thresholds” runtime error
{0;0;0}0. Runtime error (UnboundNameException): global name 'maxHumidity_' is not defined1. Traceback: line 80, in checkTheInputs, "<string>" line 282, in script
"runenergysimulation” report
{0;0}0. Current document units is in Meters1. Conversion to Meters will be applied = 1.0002. TypeError('Waarde kan niet null zijn.\r\nParameternaam: source',)3. Failed to copy the object. Returning the original objects...This can cause strange behaviour!4. [1 of 8] Writing simulation parameters...5. [2 of 8] No context surfaces...6. [3 of 8] Writing geometry...7. [4 of 8] Writing Electric Load Center - Generator specifications ...8. [5 of 8] Writing materials and constructions...9. [6 of 8] Writing schedules...10. [7 of 8] Writing loads and ideal air system...11. [8 of 8] Writing outputs...12. ...... idf file is successfully written to : c:\ladybug\unnamed\EnergyPlus\unnamed.idf13. 14. Analysis is running!...15. c:\ladybug\unnamed\EnergyPlus\eplusout.csv16. ......
Done! Read below for errors and warnings:
17. 18. Program Version,EnergyPlus, Version 8.3.0-6d97d074ea, YMD=2016.03.02 20:55,IDD_Version 8.3.019. 20. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.21. 22. ************* Beginning Zone Sizing Calculations23. 24. ** Warning ** GetInternalHeatGains: People="CLASSROOMOFFICEPEOPLE", Activity Level Schedule Name values25. 26. ** ~~~ ** fall outside typical range [70,1000] W/person for Thermal Comfort Reporting.27. 28. ** ~~~ ** Odd comfort values may result; Schedule="SCHOCCUPANCYSCHEDULE".29. 30. ** ~~~ ** Entered min/max range=[0.0,1.0] W/person.31. 32. ** Warning ** Calculated design heating load for zone=CLASSROOM is zero.33. 34. ** ~~~ ** Check Sizing:Zone and ZoneControl:Thermostat inputs.35. 36. ** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature37. 38. ** ~~~ ** ...check zone thermostat set point and design supply air temperatures39. 40. ** ~~~ ** ...zone name = CLASSROOM41. 42. ** ~~~ ** ...design sensible cooling load = 25499.10 W43. 44. ** ~~~ ** ...thermostat set point temp = 0.000 C45. 46. ** ~~~ ** ...zone temperature = 15.334 C47. 48. ** ~~~ ** ...supply air temperature = 15.000 C49. 50. ** ~~~ ** ...temperature difference = -0.33433 C51. 52. ** ~~~ ** ...calculated volume flow rate = 197273.21341 m3/s53. 54. ** ~~~ ** ...calculated mass flow rate = 237634.19357 kg/s55. 56. ** Warning ** ManageSizing: For a plant sizing run, there must be at least 1 Sizing:Plant object input. SimulationControl Plant Sizing option ignored.57. 58. ************* Testing Individual Branch Integrity59. 60. ************* All Branches passed integrity testing61. 62. ************* Testing Individual Supply Air Path Integrity63. 64. ************* All Supply Air Paths passed integrity testing65. 66. ************* Testing Individual Return Air Path Integrity67. 68. ************* All Return Air Paths passed integrity testing69. 70. ************* No node connection errors were found.71. 72. ************* Beginning Simulation73. 74. ************* Simulation Error Summary *************75. 76. ** Warning ** The following Report Variables were requested but not generated77. 78. ** ~~~ ** because IDF did not contain these elements or misspelled variable name -- check .rdd file79. 80. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL COOLING ENERGY, Frequency=Hourly81. 82. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL HEATING ENERGY, Frequency=Hourly83. 84. ************* Key=*, VarName=CHILLER ELECTRIC ENERGY, Frequency=Hourly85. 86. ************* Key=*, VarName=BOILER HEATING ENERGY, Frequency=Hourly87. 88. ************* Key=*, VarName=FAN ELECTRIC ENERGY, Frequency=Hourly89. 90. ************* Key=*, VarName=ZONE VENTILATION FAN ELECTRIC ENERGY, Frequency=Hourly91. 92. ************* Key=*, VarName=EARTH TUBE FAN ELECTRIC ENERGY, Frequency=Hourly93. 94. ************* Key=*, VarName=PUMP ELECTRIC ENERGY, Frequency=Hourly95. 96. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT LOSS ENERGY, Frequency=Hourly97. 98. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT GAIN ENERGY, Frequency=Hourly99. 100. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE COOLING ENERGY, Frequency=Hourly101. 102. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE HEATING ENERGY, Frequency=Hourly103. 104. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.105. 106. ************* EnergyPlus Sizing Error Summary. During Sizing: 3 Warning; 1 Severe Errors.107. 108. ************* EnergyPlus Completed Successfully-- 5 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 4.65sec109.…
idually and by group
3) Clean up functions to discard failed results
4) Use generated images using windows directories to delete designs (so you can bring one next to each other and discard similar ones)
5) Hide irrelevant parameters
6) View generated images in zoom
7) Individually set limits on filter parameters (using sliders)
8) Reload CAD file without having to close and open genoform
9) Much smaller UI (we want to allow the screen for design work, so the functionalities have been made into pop-ups).
10) Navigate in view to a desired design (by number)
11) Any other features our users want ? (let us know)
We hope that this version is much more easier to use and allows designers to manage what they wish to generate section by section or layer by layer.…
the scripts for awhile but they need to be updated and streamlined. in one case i am thinking to "translate" an existing GH script into a conventional rhino/python script (with perhaps a UI with dialog boxes) if possible.
i also have other contract work that runs the spectrum anywhere from reverse engineering to modeling for CNC to helping us overcome some nagging modeling issues via skype.
the preferred skill set is below.
goodwill,
jonathan
web: http://www.universaljoint.nu
blog: http://www.formpig.com
-
1. rhino and/or python scripting 2. GH scripting 3. 3D modeling 4. ACAD 5. large architecture office experience and/or architectural education 6. construction experience 7. mathematical background 8. fabrication and/or rapid prototyping background 9. attention to detail 10. low maintenance with experience collaborating over the internet …
مندان برای شرکت در کلاسها و کارگاهها
دعوت می شود
email: behrange@gmail.com از طریق
و یا شماره تماس 09197804306 جهت ثبت نام تماس حاصل نمایند
جهت شرکت در کلاسهای فوق مبلغ 3500000 ریال به شماره حساب0215461257000 بانک ملی ایران واریزنموده
و فیش واریزی را به همراه کپی کارت ملی تحویل دهید
محل برگزاری کلاسها : تهران خیابان پاسداران خیابان بهستان سوم پلاک 9 …
Rhino5 SR9. PT will not load unless you update.2- Download the PT installer (PanelingTools_2014_08_24_00.rhi) from: http://www.rhino3d.com/download/rhino/5.0/PanelingToolsV5/2- Double click the downloaded rhi file and follow the prompts to install.3- Next time you open Rhino and grasshopper, you should see the new version installed and loaded.4- The updated toolbars should be also installed. You might need to load using "ToolbarLayout" Rhino command.Documentation:There are comprehensive manuals available. Please make use of them.1- PT-Rhino: http://wiki.mcneel.com/_media/labs/panelingtools.pdf2- PT-GH: http://
wiki.mcneel.com/_media/labs/panelingtools4grasshopperprimer.pdf
New in this Release:--------------------
PT-Rhino:
1- All 2D and 3D Paneling commands, now pay attention to the attributes of the source module. Morphed geometry is no longer added to a new layer and is placed in the same layer as that of the source module(s).2- ptPanel3DCustomVariable with mean option: added support to use multiple start/end modules.3- ptPanel3DCustomVariable command with mean option: added support to use points as part of pattern.
4- Fixed history bugs to custom2d and custom3d variable commands.5- ptOffsetBorder: added bitmap and draft angle options.6- Added history support to ptGridSurface* commands.7- ptPlanarLips command is discontinued and is now replaced with the new ptTabs. The new command has "Distance" and "Recess" options to create tabs with a miter. It works with planar surfaces and polysurfaces.8- ptUnrollFaces: Many improvements and new options.9- Many other minor bug and crash fixes.PT-GH:1- Added anew component to morph variable 3D components using mean or tween method between matching curves, meshes or surfaces.2- Added the new ptOffsetGrid component of a grid.3- Updated the ptMorph2dVariable component to accept a tree structure.4- Fixed a few miscellaneous UI bugs and crashes.Feedback:As always, feedback is ve
ry much appreciated. Please post questions and reports to the following:1- Rhino discourse forum (http://discourse.mcneel.com/)2- PT forums (PT-Rhino: http://v5.rhino3d.com/group/panelingtools) and (PT-GH: http://www.grasshopper3d.com/group/panelingtools).3- Email tech (tech@mcneel.com) or reach me directly (rajaa@mcneel.com).Enjoy!Rajaa IssaRobert McNeel & Associates…
ells new products like the Firefly Interactive Prototyping Shield which mounts on top of your Arduino Uno and provides access to a number of useful input (ie. sensors) and output (ie. motors) devices. It includes features like:
Three linear slide potentiometers connected to analog pins 0, 1, and 2
Two-axis joystick connected to analog pins 3 and 4
Light sensor (photocell) connected to analog pin 5
Three push buttons connected to digital pins 2, 4, and 7
Red LED connected to digital pin 13
RGB LED connected to digital pins 3, 5, and 6
Two servo connections on digital pins 8 and 9
A connection to the Easy Stepper Driver (co-designed by Sparkfun Electronics and Brian Schmalz) to control stepper motors. The direction of the motor is controlled through digital pin 10 and the number of steps through digital pin 12
High-voltage MOSFET circuit capable of driving lights, valves, DC motors, solenoids, or anything else requiring higher voltage or current. The gate of the MOSFET is connected to digital pin 11 (PWM).
Some come take a look and let us know what you think!
…
-axes
2nd copy 6° rotation out of x-axes
3rd copy 9° rotation out of x-axes
and so on
and I want to change the rotation
I have manage to do that for each object but with more than 100 copies this is pretty uncomfortable. There must be an easier way with the array command but how can I add the rotation to each objectt?
Please help, thanks.…