al read” component in grasshopper.
But somehow it seems that the command line “TempSensor.requestTemperatures();” makes the firefly firmata somehow unstable. I have also connected 5 servo motor which move strangely irregular/wrong when the command line above is in the program. So, when I for example only control the "Digital Pin 12" in grasshopper it mainly moves the servo on Pin 11 (!) but also a bit time delayed the servo on Pin 12.
Do you have any ideas? It has to be something inside the “#include <DallasTemperature.h>” (Libary for the temperature sensor) which doesnt go together with the firefly firmata und gets something wrong in the "void WriteToPin" firmata command
Or do you may have any working codes for implementing a temperature sensor? Its doenst have to be the one i have, I could get another one.
here you can see the code: http://txt.do/drqao (a simplified version of the latest firmata including my TempSensor lines marked with "//...//TEST")
Thanks! Julian…
ells new products like the Firefly Interactive Prototyping Shield which mounts on top of your Arduino Uno and provides access to a number of useful input (ie. sensors) and output (ie. motors) devices. It includes features like:
Three linear slide potentiometers connected to analog pins 0, 1, and 2
Two-axis joystick connected to analog pins 3 and 4
Light sensor (photocell) connected to analog pin 5
Three push buttons connected to digital pins 2, 4, and 7
Red LED connected to digital pin 13
RGB LED connected to digital pins 3, 5, and 6
Two servo connections on digital pins 8 and 9
A connection to the Easy Stepper Driver (co-designed by Sparkfun Electronics and Brian Schmalz) to control stepper motors. The direction of the motor is controlled through digital pin 10 and the number of steps through digital pin 12
High-voltage MOSFET circuit capable of driving lights, valves, DC motors, solenoids, or anything else requiring higher voltage or current. The gate of the MOSFET is connected to digital pin 11 (PWM).
Some come take a look and let us know what you think!
…
be done easier, but later on the geometry will change and therefore this seems the better option. But coming back to the problem
First, there were some problems concerning the zone, although it seems solved still the “runenergysimulation” gives the following warning:
1. The simulation has not run correctly because of this severe error:
** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature
Do one of you know what went wrong? It probably will solve most of it.
Second, “set Zone Thresholds” gives the following warning:
1. Solution exception:global name 'maxHumidity_' is not defined
However, the component is missing the max humidity input on the list, has this to do something with the error?
All the components are up to date.
I hope it will be an easy fix.
Gr Lars
“set Zone Thresholds” runtime error
{0;0;0}0. Runtime error (UnboundNameException): global name 'maxHumidity_' is not defined1. Traceback: line 80, in checkTheInputs, "<string>" line 282, in script
"runenergysimulation” report
{0;0}0. Current document units is in Meters1. Conversion to Meters will be applied = 1.0002. TypeError('Waarde kan niet null zijn.\r\nParameternaam: source',)3. Failed to copy the object. Returning the original objects...This can cause strange behaviour!4. [1 of 8] Writing simulation parameters...5. [2 of 8] No context surfaces...6. [3 of 8] Writing geometry...7. [4 of 8] Writing Electric Load Center - Generator specifications ...8. [5 of 8] Writing materials and constructions...9. [6 of 8] Writing schedules...10. [7 of 8] Writing loads and ideal air system...11. [8 of 8] Writing outputs...12. ...... idf file is successfully written to : c:\ladybug\unnamed\EnergyPlus\unnamed.idf13. 14. Analysis is running!...15. c:\ladybug\unnamed\EnergyPlus\eplusout.csv16. ......
Done! Read below for errors and warnings:
17. 18. Program Version,EnergyPlus, Version 8.3.0-6d97d074ea, YMD=2016.03.02 20:55,IDD_Version 8.3.019. 20. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.21. 22. ************* Beginning Zone Sizing Calculations23. 24. ** Warning ** GetInternalHeatGains: People="CLASSROOMOFFICEPEOPLE", Activity Level Schedule Name values25. 26. ** ~~~ ** fall outside typical range [70,1000] W/person for Thermal Comfort Reporting.27. 28. ** ~~~ ** Odd comfort values may result; Schedule="SCHOCCUPANCYSCHEDULE".29. 30. ** ~~~ ** Entered min/max range=[0.0,1.0] W/person.31. 32. ** Warning ** Calculated design heating load for zone=CLASSROOM is zero.33. 34. ** ~~~ ** Check Sizing:Zone and ZoneControl:Thermostat inputs.35. 36. ** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature37. 38. ** ~~~ ** ...check zone thermostat set point and design supply air temperatures39. 40. ** ~~~ ** ...zone name = CLASSROOM41. 42. ** ~~~ ** ...design sensible cooling load = 25499.10 W43. 44. ** ~~~ ** ...thermostat set point temp = 0.000 C45. 46. ** ~~~ ** ...zone temperature = 15.334 C47. 48. ** ~~~ ** ...supply air temperature = 15.000 C49. 50. ** ~~~ ** ...temperature difference = -0.33433 C51. 52. ** ~~~ ** ...calculated volume flow rate = 197273.21341 m3/s53. 54. ** ~~~ ** ...calculated mass flow rate = 237634.19357 kg/s55. 56. ** Warning ** ManageSizing: For a plant sizing run, there must be at least 1 Sizing:Plant object input. SimulationControl Plant Sizing option ignored.57. 58. ************* Testing Individual Branch Integrity59. 60. ************* All Branches passed integrity testing61. 62. ************* Testing Individual Supply Air Path Integrity63. 64. ************* All Supply Air Paths passed integrity testing65. 66. ************* Testing Individual Return Air Path Integrity67. 68. ************* All Return Air Paths passed integrity testing69. 70. ************* No node connection errors were found.71. 72. ************* Beginning Simulation73. 74. ************* Simulation Error Summary *************75. 76. ** Warning ** The following Report Variables were requested but not generated77. 78. ** ~~~ ** because IDF did not contain these elements or misspelled variable name -- check .rdd file79. 80. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL COOLING ENERGY, Frequency=Hourly81. 82. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL HEATING ENERGY, Frequency=Hourly83. 84. ************* Key=*, VarName=CHILLER ELECTRIC ENERGY, Frequency=Hourly85. 86. ************* Key=*, VarName=BOILER HEATING ENERGY, Frequency=Hourly87. 88. ************* Key=*, VarName=FAN ELECTRIC ENERGY, Frequency=Hourly89. 90. ************* Key=*, VarName=ZONE VENTILATION FAN ELECTRIC ENERGY, Frequency=Hourly91. 92. ************* Key=*, VarName=EARTH TUBE FAN ELECTRIC ENERGY, Frequency=Hourly93. 94. ************* Key=*, VarName=PUMP ELECTRIC ENERGY, Frequency=Hourly95. 96. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT LOSS ENERGY, Frequency=Hourly97. 98. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT GAIN ENERGY, Frequency=Hourly99. 100. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE COOLING ENERGY, Frequency=Hourly101. 102. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE HEATING ENERGY, Frequency=Hourly103. 104. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.105. 106. ************* EnergyPlus Sizing Error Summary. During Sizing: 3 Warning; 1 Severe Errors.107. 108. ************* EnergyPlus Completed Successfully-- 5 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 4.65sec109.…
berfläche des Grasshopper Programms
Funktionsprinzip eines grafischen Algorithmus-Editors (Datenfluss)
Unterscheidung von Parametern (Datentypen) und Komponenten (Datenverarbeitung)
Erzeugung, Bearbeitung und Analyse von Geometrie-Typen: Punkte, Vektoren, Linien, Kurven, Flächen (surfaces, brep) und Netze (meshes)
Strukturierung der Daten anhand von Listen und Bäumen
unterschiedliche Verknüpfungsmöglichkeiten von Parametern (data matching)
praxisnahe Grundlagen der Geometrie und Vektorrechnung für generatives Design
effizienter Aufbau von parametrischen Modellen anhand Übungsaufgaben
Auszug von Daten aus Modellen für die Fertigung; Daten aus Tabellen (Excel, CSV) importieren, exportieren
Einsatz von benutzerdefinierten Komponenten (custom components)
Vorkenntnisse: Rhinoceros3d Benutzeroberfläche der Software: Englisch Unterrichtssprache: Deutsch, auf Wunsch auch Englisch
Details und Anmeldung:
www.vhs-stuttgart.de
Dieser Kurs wird in Kooperation mit ifBau gGmbH und VHS Stuttgart angeboten, und wird von ifBau als Fortbildung für Mitglieder der Architektenkammer BW anerkannt.
Trainer: Peter Mehrtens
Kursdauer: 3 Tage / 8 Stunden pro Tag
Freitag, 24.01.2014, 09:00-17:00 Uhr Samstag, 25.01.2014, 09:00-17:00 Uhr Sonntag, 26.01.2014, 09:00-17:00 Uhr Ort: VHS Stuttgart, Fritz-Elsas-Str. 46/48
Teilnahmegebühr: 510,00 € Teilnehmerzahl: 4-10 Personen
…
you post a screenshot of what the message coming from its readMe! output looks like?2) Close your Grasshopper and Rhino.3) Download "Revo Uninstaller Pro" from here. It is free for first 30 days, which is what we need.4) Right click on the RevoUninProSetup.exe and check if the file is blocked. If it is, unblock it.5) Run the RevoUninProSetup.exe file and install "Revo Uninstaller Pro".6) Uninstall "MapWinGIS" with "Revo Uninstaller Pro". It is important that "Revo Uninstaller Pro" deletes not only files from MapWinGIS installation folder, but also all other leftovers (as registry inputs). Here is a small tutorial on how to do that. Watch it from 6:10 till the end.7) Restart your PC8) When your Windows boots up, make sure that you are logged in as Administrator!9) In your Start menu's search box type: "UAC", which will find your User Account Control Settings. Click on it, and a new window will open. Set the bar on the left to "Never notify".10) Turn off your Windows Firewall.11) Then turn off your custom Firewall (in case you have another one, besides standard Windows Firewall).12) Completely turn off your Antivirus.13) Download again the MapWinGIS-only-v4.9.4.2-x64.exe.exe file from here.14) Right click on the MapWinGIS-only-v4.9.4.2-x64.exe file and see if it is blocked. If it is, unblock it.15) Right click on MapWinGIS-only-v4.9.4.2-x64.exe file and choose: "Run as"... Administrator.16) One the installation preparation steps start, choose "Full installation". Wait for the MapWinGIS installation to finish.17) Right-click on "Rhino 5" icon and then choose: "Run as administrator".18) Open the the ironpython_admin.gh file again, and again post a screenshot of the message coming from its readMe! output.19) Drop the "Gismo Gismo" component to Grasshopper canvas. Post a screenshot of the message coming out from its readMe! output.
So we will need in total three screenshots of the readMe! output messages.
Thank you once again for being patient, and sorry for the large number of steps.…
Added by djordje to Gismo at 1:52am on April 9, 2017
r [String Split] in version 0.9.0014)
The [Timer] prompts a component to up date at the set interval. in this case every 1 seconds.
The [Time] param is a placeholder for a time in the same way that a [Number] param can hold real numbers.
By using "Now" as the input to the [Time] param you will get the current time when the param updates. therefore every second it resets to the current time.
The [Text Split] is there to separate the output of [Time] in a string format at every colon ":"
Therefore "Monday, 13-MAY-2013 (11:23:30)" would become:
0 Monday, 13-MAY-2013 (1
1 23
2 30)
The next two components use this to convert it into the current seconds. Because we are after the last item "30)" we can use [List Item] on a reversed list to get the last item.
Now we have to remove the ")" with [Replace String] but we are replacing it with nothing so it disappears.
The Arrow is part of the Sketch Tool Functionality of the canvas.
Lastly the 3 different inputs should go into the three different Inputs of the [Stream Filter]
…
hange to a rectangle or a sequence of lines to get the tube geometry. Author of the video explained how to do this in the comments, but that didn't help. :(
"Alan Rodriguez Carrillo 1 year ago + Aldo Villanueva Hi, what you can do is try to handle points (4) with the ListITEM component and change the order of relation, for example (0,1) (1,2) (2,3) (3, 4) (4.0) in a panel. Subsequently do the relation of points through a line from points or LineSDL and elaborate the same steps that are explained in this video. Thanks.
Carlos González Puchol 11 months ago + Aldo Villanueva + Alan Rodríguez Carrillo Buenas, Alan and Aldo. I made a closed, tube design. First I listed the 4 points and put them in order with the polyline the polyline, making it closed. Then I had to close them also in the last steps before doing the triangulation."
Can anyone explain how to make this work ? It seems easy. For a person that knows the trick :))
https://www.dropbox.com/s/9dnyfoielum6m1r/PABELLON_last.3dm?dl=0 https://www.dropbox.com/s/y8xdiaf66xbyn9l/PAVILION.gh?dl=0…