ommand as well. You can get the GH plugin from here. http://www.tsplines.com/forum/viewtopic.php?f=9&t=30340
If you only have V2 i would download the trial from here that has 25 saves same as rhino trial but does not work with the GH Plug-in unless you request a 30 day trial verison http://www.tsplines.com/products/tsplines-for-rhino/overview.html
Hope this Helps.
Matt…
ed at the center of each cell). I have placed 30 points on each of the cells and want to create a curve connecting each point with the reciprocating point on the other layers of the cell strucutre.
I am uploading the file, maybe someone would be kind enough to tell me what i am doing wrong.
3march-1.gh
cleaned%20meta%20voro%20set%20connect.3dm…
coworking. Il corso prevede la trattazione delle tematiche di base della modellazione generativa, con l'inserimento di lezioni basate sulla filosofia progettuale della modellazione generativa e basi di analisi matematica.
Il corso ha durata di 30 ore con appuntamenti bisettimanali (lunedì e mercoledì) a partire da lunedì 03 ottobre. Per maggiori informazioni contattate il docente delcorso e scaricate il programma
____________
Cavallette Generative is the new Grasshopper Level I course offered by Mandarino Blu visual communication LAB. The event is organized by the support ofMultiverso, a co-working company. The course includes the discussion of the basic themes of generative modeling, such as design philosophy and mathematical analysis.
The course lasts 30 hours with twice-weekly meetings (Monday and Wednesday) from Monday, October 3. For more information contact theinstructor of the course and download the program…
vanzada], evento patrocinado por Rhinoceros y Grasshopper y en colaboración con la Universidad Federico Santa María.
En el WS1 se utilizará Grasshopper para desarrollar estrategias de diseño generativo de estas “pieles responsivas”, entendidas como un nuevo tipo de infraestructura capaz de adaptarse a diferentes configuraciones geométricas y topológicas con respecto a su entorno. Las pieles se desarrollarán en el sitio de un proyecto específico y deberán responder a las necesidades de un contexto existente.
Durante el workshop se desarrollarán herramientas de mapeo y diagramación, capaces de capturar el comportamiento dinámico de agentes ambientales[radiación solar, intensidad, orientación, etc.] y patrones de interacción humana [flujos peatonales, niveles de ocupación, etc.]. Estos diagramas serán incorporados como datos de entrada que activan/modifican la estructura interna de los modelos paramétricos a desarrollar. Utilizando Grasshopper como un motor de diferenciación donde cada modelo será el resultado de las lógicas de negociación aplicadas en diferentes instancias temporales.
WS1 tendrá una duración de 5 días (17:00 a 21:00 hrs), del 30 de Agosto al 03 de Septiembre. Será realizado en la USM Campus San Joaquín, Av. Vicuña Mackenna 3939, Metro Camino Agrícola.…
ies a step further towards informative models, how to extract data through a parametric process and design analysis which leads to performance based schema.The workshop will cover some advanced modeling techniques in grasshopper along with some useful grasshopper plugins "GECO,WEAVERBIRD,KANGAROO and more". An introductory to ecotect analysis will also be inculded.The workshop is dedicated to intermediate Grasshopper users " knowledge of GRASSHOPPER equivalent to which gained in Parametricisim WS or higher is preferred".Knowledge of ECOTECT is a plus but not necessary".
Schedule :Deadline for Registration : May 13,2013Workshop Starts : Thursday, May 16, 2013 - 5:30 pmThe workshop consists of 10 lectures, Each lecture lasts for 3 hours.3 lectures per week (Sun, Tues & Thur) ---------------------------------------------------Fees : 600 L.EYou have to fill the Registration Form below for place reservation.We only have few places available. ---------------------------------------------------Prerequisite :-Students should bring their own laptops---------------------------------------------------Registration Form:https://docs.google.com/forms/d/1qd7cTRi8fGJ3OiVPjiNzHA0ZRmXI2qCvk1CUQ-X_4H8/viewformYou can view previous Parametric workshops,Student work & presnetation here :Previous workshophttps://www.facebook.com/events/469048376477647/https://www.facebook.com/media/set/?set=a.548388031851299.1073741826.470747186282051&type=1https://www.facebook.com/events/178326265647678/…
en that name). For example, in my grammar:
F = FXX = %(50:F[-X][+X]; 30:F[-X][X][+X]; 20:F[X])Axiom => F0 - F1 - FX2 - FF[-X][+X] with some seed, or FF[-X][X][+X] with other seed, or FF[X] with other.
And context-sensitive means, for example in my grammar, the rule:X = >(-F:+FX; +F:F[-F[-X][+FX]]) if the previous symbols (in the string of L-System, on the left when a X is read) is a -F, then X will be +FX, but if the symbol is +F, then X will be F[-F[-X][+FX]].
Or:
X = G(2: +++F; 3:++F; 4:+F) means that in the second generation X will be +++F, in the fourth will be +F.
Or:
X = IF(BL = 3: +F, -F) It means that if the branch level (BL) of X is 3, will be +F, otherwise -F.
And parametric is something like:
F = F(ValueA:x+0.5; ValueB: 6*BL), F have two metadata (ValueA and ValueB), and when "x" is read, is replaced by the value of that attribute of his predecessor, ie, will be the ancestor valueA+0.5. And BL is the branch level of X, which means that if X have a Path like {0,0,1} or {0,3,0} (three indices), ValueB will be 12, for that X in that generation/iteration.
…
imilar topic with a Windows 10 user, which successfully fixed this issue.If you are tiny little patient, I think we can try the same steps in your Windows 7 case.For start, try these three steps:1) Close Rhino. Restart your PC. 2) Once the PC boots up, double click on the "regMapWinGIS.cmd" file in "MapWinGIS" installation folder.3) When it closes the Command Prompt window it opened, try running Rhino, Grasshopper and drop the "Gismo Gismo" component on the canvas (Grasshopper working area).If this does not help (you get the same COM class factory CLSID error message coming out from the "Gismo Gismo" component), then try the following steps, one by one:
1) Close Grasshopper and Rhino2) Run the Revo Uninstaller Pro and uninstall your MapWinGIS application along with removing all the leftovers from the registry. You can download 30 days trial version of it from here. Here is a youtube example of a bit older Revo Uninstaller. But the important part is that is shows how registry leftovers are removed.3) Restart your PC, and once it boots again, make sure that you are logged in as an Adminstrator!4) In your Start menu's search box type: "UAC", which will find your User Account Control Settings. Click on it, and a new window will open. Set the bar on the left to "Never notify".5) Turn off your Antivirus, which ever it is.6) Download the 64 bit version of v4.9.4.2 MapWinGIS.7) Right click on downloaded MapWinGIS-only-v4.9.4.2-x64.exe file, and choose "Properties". If there is "Unblock" button click on it, and then click on "OK". If there is no "Unblock" button, just click on "OK".8) Left double click on MapWinGIS-only-v4.9.4.2-x64.exe file and install it to "C:\dev\MapWinGIS" folder. Choose "Full installation" during installation process!9) In your Start menu's search box type: "CMD". Once the "Command prompt" appears do not left click on it! Instead right click on it, and choose "Run as Administrator".10) A command prompt window will open. Type the following command:
"your_regsvr32_folder_path\regsvr32.exe" /u /s c:\dev\mapwingis\mapwingis.ocx
If command does not result in an error message, then type this one afterwards:
"your_regsvr32_folder_path\regsvr32.exe" /s c:\dev\mapwingis\mapwingis.ocx
11) If no error appeared again, then open your Rhino and Grasshopper and check what "Gismo Gismo" component prints from its "readMe!" output.If errors appeared, please post their screenshots. Thank you in advance.
Please accept my apologies for the large number of steps. Some of them are quite simple actually (click on this, download that...).…
Added by djordje to Gismo at 12:58pm on November 28, 2017
to 10 = color 2
10 to 15 = color 3
15 to 30 = color 4
....
I divide the surface by number of segments. How can I divide the surface by distance between
any help...…
be done easier, but later on the geometry will change and therefore this seems the better option. But coming back to the problem
First, there were some problems concerning the zone, although it seems solved still the “runenergysimulation” gives the following warning:
1. The simulation has not run correctly because of this severe error:
** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature
Do one of you know what went wrong? It probably will solve most of it.
Second, “set Zone Thresholds” gives the following warning:
1. Solution exception:global name 'maxHumidity_' is not defined
However, the component is missing the max humidity input on the list, has this to do something with the error?
All the components are up to date.
I hope it will be an easy fix.
Gr Lars
“set Zone Thresholds” runtime error
{0;0;0}0. Runtime error (UnboundNameException): global name 'maxHumidity_' is not defined1. Traceback: line 80, in checkTheInputs, "<string>" line 282, in script
"runenergysimulation” report
{0;0}0. Current document units is in Meters1. Conversion to Meters will be applied = 1.0002. TypeError('Waarde kan niet null zijn.\r\nParameternaam: source',)3. Failed to copy the object. Returning the original objects...This can cause strange behaviour!4. [1 of 8] Writing simulation parameters...5. [2 of 8] No context surfaces...6. [3 of 8] Writing geometry...7. [4 of 8] Writing Electric Load Center - Generator specifications ...8. [5 of 8] Writing materials and constructions...9. [6 of 8] Writing schedules...10. [7 of 8] Writing loads and ideal air system...11. [8 of 8] Writing outputs...12. ...... idf file is successfully written to : c:\ladybug\unnamed\EnergyPlus\unnamed.idf13. 14. Analysis is running!...15. c:\ladybug\unnamed\EnergyPlus\eplusout.csv16. ......
Done! Read below for errors and warnings:
17. 18. Program Version,EnergyPlus, Version 8.3.0-6d97d074ea, YMD=2016.03.02 20:55,IDD_Version 8.3.019. 20. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.21. 22. ************* Beginning Zone Sizing Calculations23. 24. ** Warning ** GetInternalHeatGains: People="CLASSROOMOFFICEPEOPLE", Activity Level Schedule Name values25. 26. ** ~~~ ** fall outside typical range [70,1000] W/person for Thermal Comfort Reporting.27. 28. ** ~~~ ** Odd comfort values may result; Schedule="SCHOCCUPANCYSCHEDULE".29. 30. ** ~~~ ** Entered min/max range=[0.0,1.0] W/person.31. 32. ** Warning ** Calculated design heating load for zone=CLASSROOM is zero.33. 34. ** ~~~ ** Check Sizing:Zone and ZoneControl:Thermostat inputs.35. 36. ** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature37. 38. ** ~~~ ** ...check zone thermostat set point and design supply air temperatures39. 40. ** ~~~ ** ...zone name = CLASSROOM41. 42. ** ~~~ ** ...design sensible cooling load = 25499.10 W43. 44. ** ~~~ ** ...thermostat set point temp = 0.000 C45. 46. ** ~~~ ** ...zone temperature = 15.334 C47. 48. ** ~~~ ** ...supply air temperature = 15.000 C49. 50. ** ~~~ ** ...temperature difference = -0.33433 C51. 52. ** ~~~ ** ...calculated volume flow rate = 197273.21341 m3/s53. 54. ** ~~~ ** ...calculated mass flow rate = 237634.19357 kg/s55. 56. ** Warning ** ManageSizing: For a plant sizing run, there must be at least 1 Sizing:Plant object input. SimulationControl Plant Sizing option ignored.57. 58. ************* Testing Individual Branch Integrity59. 60. ************* All Branches passed integrity testing61. 62. ************* Testing Individual Supply Air Path Integrity63. 64. ************* All Supply Air Paths passed integrity testing65. 66. ************* Testing Individual Return Air Path Integrity67. 68. ************* All Return Air Paths passed integrity testing69. 70. ************* No node connection errors were found.71. 72. ************* Beginning Simulation73. 74. ************* Simulation Error Summary *************75. 76. ** Warning ** The following Report Variables were requested but not generated77. 78. ** ~~~ ** because IDF did not contain these elements or misspelled variable name -- check .rdd file79. 80. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL COOLING ENERGY, Frequency=Hourly81. 82. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL HEATING ENERGY, Frequency=Hourly83. 84. ************* Key=*, VarName=CHILLER ELECTRIC ENERGY, Frequency=Hourly85. 86. ************* Key=*, VarName=BOILER HEATING ENERGY, Frequency=Hourly87. 88. ************* Key=*, VarName=FAN ELECTRIC ENERGY, Frequency=Hourly89. 90. ************* Key=*, VarName=ZONE VENTILATION FAN ELECTRIC ENERGY, Frequency=Hourly91. 92. ************* Key=*, VarName=EARTH TUBE FAN ELECTRIC ENERGY, Frequency=Hourly93. 94. ************* Key=*, VarName=PUMP ELECTRIC ENERGY, Frequency=Hourly95. 96. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT LOSS ENERGY, Frequency=Hourly97. 98. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT GAIN ENERGY, Frequency=Hourly99. 100. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE COOLING ENERGY, Frequency=Hourly101. 102. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE HEATING ENERGY, Frequency=Hourly103. 104. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.105. 106. ************* EnergyPlus Sizing Error Summary. During Sizing: 3 Warning; 1 Severe Errors.107. 108. ************* EnergyPlus Completed Successfully-- 5 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 4.65sec109.…
: escultura, pintura, música, digitalartesans: joieria, tèxtil, moda, cuïr, vidre i vitrallsdissenyadors: industrials, mobles, gràfics, il·lustració, patrons, cuina i reposteriaarquitectes: interiors, estructures, construcció, instal·lacions, escenografies, decoracióenginyers: processos, industrials, materials
Introducció:Aplicació de les tècniques de fabricació digital a través d’eines (software) i tecnologies (hardware) amb l’objectiu de facilitar la introducció d’aquestes eines dins dels processos creatius i executius dels diferents camps de l’art i el disseny. El curs parteix d’un desplegament teòric i tècnic genèric, per acabar centrant-se en el desenvolupament d’un projecte personal que explori la disciplina concreta del estudiant.
Informació a la web de l’Escola MassanaInformació a la web de CODA
Dates: 05.03.2012 al 25.06.2012Dies: Dilluns i DovendresHorari: 17:00 a 20:30 horesLloc: Escola Massana. C/Hospital, 56 08001 Barcelona. Metro: Liceu
Contacte professors:pep.tornabell(at)coda-office.comenrique.soriano(at)coda-office.com…
Added by Pep Tornabell at 3:12am on December 20, 2012