ncepts and features of Grasshopper at an accelerated pace in an instructor-led online environment.
Session Schedule: 9:00am-10:45am Lecture/Classwork Break 10:45am-11:00am 11:00am-12:30pm Lecture/Classwork 12:30pm-1:00pm Questions (optional participation)
Details: An outline of the class material is available here. The class will be conducted in English using the GoToTraining software. You will need Rhino 4.0 for Windows or the Rhino 5.0 for Windows beta installed. You will also need the latest build of Grasshopper. You may use the Rhino 4.0 for Windows evaluation version, however you will be limited to 25 saves. Using the Rhino for OSX WIP is not acceptable for this class.…
Angeles, which has 12% of the year made comfortable, and Shiraz, Iran, which also has 12% comfortable (assuming default parameters).
Jerusalem also makes sense to me. There is only a maximum possible 9% of the year that is inside the polygon (you'll see this if you set the timeConstant to a very high number). The default strategyPar makes 6% of these hours comfortable and 3% without cool enough temperatures in the previous hours. This seems reasonable to me.
I could be convinced to change the default time constant to 12 hours (instead of 8) as I know that 12 is the default of climate consultant but that seemed really idealized in my opinion. You'll need really high exposed mass and insulation without much internal heat gain to make conditions stable for more than 8 hours in my opinion.
As for the solarHeatCapacity, I get changes when I drop it down to 10 W/m2 or boost it up to 100 W/m2. It's definitely a parameter that operates on an "order of magnitude" scale and little tweaks to it won't change it too much. You can think of this number as representative of a lot of other physical properties: most notably the depth of the space being passively heated and the thermal mass of that space's materials that participate in heat exchange over the time constant. Climate consultant uses a default assumption of 30 W/m2 but, from my calculations, this is likely assuming a space that has a facade to floor area ratio that is greater than 1. If we say that we need to raise the temperature of 10 cm of an exposed concrete floor for passive heating purposes, and we have a facade-to-floor area ratio of 1:
Required solar flux = ((1 facade-to-floor ratio) x (0.1 m3 of concrete) x (2400 kg/m3 concrete density) x (880 J/kg-K concrete specific heat capacity)) / 3600 seconds/hour
This lands you with a required solar flux of 58 W, which is almost twice the 30 W climate consultant default. While me might say that not all 10 cm of concrete participates over the course of a default 8-hour time constant (most of the action is probably within the first 5 cm), we also have to account for things like transmittance of solar though the window, which, for triple pane, is probably only half of the incident solar. So 50 W seemed to be a more reasonable rule of thumb from my perspective, essentially assuming a facade-to-floor ratio of roughly 1 with 5 cm of concrete participating in an 8 hour heat exchange and a little more than half of solar heat getting through a fully glazed window.
Let me know if that makes sense or if you have any suggestions,
-Chris…
igitais de forma criativa e rigorosa, para a concepção de modelos 3D– Familiarizar-se com as lógicas de criação de geometrias tridimensionais NURBS.- Desenvolver técnicas de criação de imagens fotorealistas com o motor de render V-Ray- Introduzir as lógicas paramétricas e associativas processo criativo.- Introduzir novas lógicas de BIM no processo estrutural (Building Information Modeling).# INFORMAÇÕES E INSCRIÇÕESinfo@rhino3dportugal.comAna Fonseca: 917140716 Mais informações disponíveis no site: www.rhino3dportugal.com# FORMADORES Brimet Silva ( Authorized Rhino Trainer )
...................................................
Curso de Rhino3D Nível I
6, 7 e 9 de Julho9h-13h e 14h-18h (sessões diárias de 8h).....................................................Curso de Vray-Nível I
12 e 14 de Julho9h-13h e 14h-18h (sessões diárias de 8h).................................................Curso de Grasshopper Nível I
16 e 18 de Julho9h-13h e 14h-18h (sessões diárias de 8h).................................................
VisualARQ e Rhino BIM- Nível I
21 e 23 de Julho9h-13h e 14h-18h (sessões diárias de 8h)
…
sando las nuevas tecnologías de la información en la arquitectura para la gestión del conocimiento de sistemas que desarrollen estructuras sustentables, desde los procesos de diseño generativos o algorítmicos. Donde se contempla la P.O.O. (programación orientada a objetos) como nuevo lenguaje de expresión para el arquitecto-diseñador en el siglo XXI.Los talleres están pensados para sigan un hilo conductual en el que al mismo tiempo que se enseña se investiga y experimenta. Por primera vez se contará con diversos miembros de SEED como docentes de forma presencial y por video conferencia, logrando de esta forma acercar a los especialistas que se encuentran en Europa a los asistentes de los talleres sin encarecer los costos.+info:http://www.studioseed.net/ adn-methodology/
Los talleres están dirigidos a personas que tengan o quieran conseguir un perfil alto de innovación, creatividad, flexibilidad: profesionales con actividades de dirección, gerencia, proyectistas, investigadores, así como a estudiantes a partir de 5to semestre en adelante. Cada taller abarca perfiles diversos de profesionales, mientras unos están más orientados a directivos y gerencias, otros más a proyectistas.
LOS TALLERES:FAB DIG I / ITESM – CEM / Estado de México / 20 hrs / 8 – 11 al de diciembre 2011 (En este taller no se aplican descuentos ni becas)PARAMETRIC GREEN HOUSING / Colegio de Arquitectos del estado de Jalisco (Por confirmar Sede) / Guadalajara / 20h + 5h proyecto / 30 enero 2012 al 4 de diciembre 2012FAB DIG II / ITESM – CEM / Estado de México / 30h + 5h proyecto / 8 a 12 febrero 2012TERCERA REVOLUCIÓN INDUSTRIAL: TIC`s + SOSTENIBILIDAD. Procesos y paradigmas emergentes / Querétaro / 20 hrs / 15 al 18 de febrero 2012INTRODUCCIÓN AL DISEÑO GENERATIVO / UAM-azc / DF / 8hrs / 13, 14 de enero (Costo representativo $650, máximo 40 personas, mínimo 15 personas)INTRODUCCIÓN A: SCRIPTING CON GRASSHOPPER ( Python) Y PLUGINS / Estudio SEED México / Estado de México / 30 hrs / 23, 24, 25 febrero y 1,2, 3 de marzo 2012…
Added by SEED studio at 3:30am on November 24, 2011
be done easier, but later on the geometry will change and therefore this seems the better option. But coming back to the problem
First, there were some problems concerning the zone, although it seems solved still the “runenergysimulation” gives the following warning:
1. The simulation has not run correctly because of this severe error:
** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature
Do one of you know what went wrong? It probably will solve most of it.
Second, “set Zone Thresholds” gives the following warning:
1. Solution exception:global name 'maxHumidity_' is not defined
However, the component is missing the max humidity input on the list, has this to do something with the error?
All the components are up to date.
I hope it will be an easy fix.
Gr Lars
“set Zone Thresholds” runtime error
{0;0;0}0. Runtime error (UnboundNameException): global name 'maxHumidity_' is not defined1. Traceback: line 80, in checkTheInputs, "<string>" line 282, in script
"runenergysimulation” report
{0;0}0. Current document units is in Meters1. Conversion to Meters will be applied = 1.0002. TypeError('Waarde kan niet null zijn.\r\nParameternaam: source',)3. Failed to copy the object. Returning the original objects...This can cause strange behaviour!4. [1 of 8] Writing simulation parameters...5. [2 of 8] No context surfaces...6. [3 of 8] Writing geometry...7. [4 of 8] Writing Electric Load Center - Generator specifications ...8. [5 of 8] Writing materials and constructions...9. [6 of 8] Writing schedules...10. [7 of 8] Writing loads and ideal air system...11. [8 of 8] Writing outputs...12. ...... idf file is successfully written to : c:\ladybug\unnamed\EnergyPlus\unnamed.idf13. 14. Analysis is running!...15. c:\ladybug\unnamed\EnergyPlus\eplusout.csv16. ......
Done! Read below for errors and warnings:
17. 18. Program Version,EnergyPlus, Version 8.3.0-6d97d074ea, YMD=2016.03.02 20:55,IDD_Version 8.3.019. 20. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.21. 22. ************* Beginning Zone Sizing Calculations23. 24. ** Warning ** GetInternalHeatGains: People="CLASSROOMOFFICEPEOPLE", Activity Level Schedule Name values25. 26. ** ~~~ ** fall outside typical range [70,1000] W/person for Thermal Comfort Reporting.27. 28. ** ~~~ ** Odd comfort values may result; Schedule="SCHOCCUPANCYSCHEDULE".29. 30. ** ~~~ ** Entered min/max range=[0.0,1.0] W/person.31. 32. ** Warning ** Calculated design heating load for zone=CLASSROOM is zero.33. 34. ** ~~~ ** Check Sizing:Zone and ZoneControl:Thermostat inputs.35. 36. ** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature37. 38. ** ~~~ ** ...check zone thermostat set point and design supply air temperatures39. 40. ** ~~~ ** ...zone name = CLASSROOM41. 42. ** ~~~ ** ...design sensible cooling load = 25499.10 W43. 44. ** ~~~ ** ...thermostat set point temp = 0.000 C45. 46. ** ~~~ ** ...zone temperature = 15.334 C47. 48. ** ~~~ ** ...supply air temperature = 15.000 C49. 50. ** ~~~ ** ...temperature difference = -0.33433 C51. 52. ** ~~~ ** ...calculated volume flow rate = 197273.21341 m3/s53. 54. ** ~~~ ** ...calculated mass flow rate = 237634.19357 kg/s55. 56. ** Warning ** ManageSizing: For a plant sizing run, there must be at least 1 Sizing:Plant object input. SimulationControl Plant Sizing option ignored.57. 58. ************* Testing Individual Branch Integrity59. 60. ************* All Branches passed integrity testing61. 62. ************* Testing Individual Supply Air Path Integrity63. 64. ************* All Supply Air Paths passed integrity testing65. 66. ************* Testing Individual Return Air Path Integrity67. 68. ************* All Return Air Paths passed integrity testing69. 70. ************* No node connection errors were found.71. 72. ************* Beginning Simulation73. 74. ************* Simulation Error Summary *************75. 76. ** Warning ** The following Report Variables were requested but not generated77. 78. ** ~~~ ** because IDF did not contain these elements or misspelled variable name -- check .rdd file79. 80. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL COOLING ENERGY, Frequency=Hourly81. 82. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL HEATING ENERGY, Frequency=Hourly83. 84. ************* Key=*, VarName=CHILLER ELECTRIC ENERGY, Frequency=Hourly85. 86. ************* Key=*, VarName=BOILER HEATING ENERGY, Frequency=Hourly87. 88. ************* Key=*, VarName=FAN ELECTRIC ENERGY, Frequency=Hourly89. 90. ************* Key=*, VarName=ZONE VENTILATION FAN ELECTRIC ENERGY, Frequency=Hourly91. 92. ************* Key=*, VarName=EARTH TUBE FAN ELECTRIC ENERGY, Frequency=Hourly93. 94. ************* Key=*, VarName=PUMP ELECTRIC ENERGY, Frequency=Hourly95. 96. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT LOSS ENERGY, Frequency=Hourly97. 98. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT GAIN ENERGY, Frequency=Hourly99. 100. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE COOLING ENERGY, Frequency=Hourly101. 102. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE HEATING ENERGY, Frequency=Hourly103. 104. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.105. 106. ************* EnergyPlus Sizing Error Summary. During Sizing: 3 Warning; 1 Severe Errors.107. 108. ************* EnergyPlus Completed Successfully-- 5 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 4.65sec109.…
d so 36 renders.
The Gray animation controller output a norm which is the time normalized, I used it to move point on Z axis, so to move up the color.
You will have to plug the texure adress to a Gray Bitmap that is pluged to Gray Diffuse then to Gray material ...
Et voilà !
Not so hard
…
R Light Studio - Georg Sochurek Schnelle Beleuchtungsoptimierung mit HDR Light Studio: HDRI-Environment-Maps in Echtzeit ganz einfach erstellen und bearbeiten 10:45 - 11:45: C4D und Adobe Photoshop - Christoph Schindelar Prototyping für einen Wintersportartikel-Hersteller mit Cinema 4D 12:00 - 13:00: Autodesk 3ds max - Daniel Daghofer Software für 3D-Modellierung und Animation 13:30 - 13:30 Pause 13:30 - 14:30: MODO - Mathias Zellerhof Produktdesign leicht gemacht - mit modo 701 von TheFoundry 14:45 - 15:45: Rhino 5 - Dipl. Ing. Fabio Palvelli Advanced NURBS-Modelling mit Rhino 5 für Designer und Architekten 16:00 - 17:00: Autodesk Maya - David Wuchte Umfassende 3D-Animationssoftware 17:15 - 18:15: 3D Coat - Christoph Schindelar Feinmodellierung (Sculpting) & Design von Handy-Designelementen mit 3D Coat Zusätzlich haben Sie die Möglichkeit in den Pausen / im Anschluß div. Hardware zu testen / anzusehen: Monitore: CG Serie von EIZO (inkl. Swing Sensor/Colorimeter) EIZO Foris mit EIZO Spyder EIZO Touchscreen NEC Spectraview Reference inkl. X-Rite Colorimeter Stiftdisplays: WACOM Cintiqs 3D Mäuse: SpaceMouse Pro SpacePilot Pro…
h 4, Floor 2 with7, Floor3 with 12...etc)
The only things fixed are the 3 anchors.
Actually, this is very banal geometry, and it seems dosent make any sense to make it parametically. But once if we have to change it along a freeform tube, then it becames more complicate.
So, if anybody have idea how to approach it? I would very appreciate to ur opinion.
…
Added by Frank Tseng at 10:42am on November 3, 2011
large sets of data (~3months, with 1 vector per hour). I have the solar vectors and i would like to add them on a given point, but only if:
the lines connecting the sun position to the center of the model do not intersect any given geometry. That is, i need to select from the group of lines, only the ones that do not intersect (BBX+CLX components) the brep. How can i do that?
Given this rule i also dont see how can i add several vectors, since i've only seen 2 vectors adding via the mathematical addition tool. Do i need to set them to one point?
[edit] i've solved this issue using mass addition tool for the 3 components (x,y,z) and feeding it with the flattened vector list.
Thanks in advance for any suggestion…
rting planar surface is a highly irregular one with 11 curves, and 12 points I'm using as anchors. As a result the mesh work I am generating with weaverbird is a mess and the whole structure looks incredibly unrefined. I've been trying to track down some good information on smoothing, equalizing and conformalizing techniques but haven't found any. I've seen demo videos but no accompanying definitions and I am very new to the kangaroo engine so working it out by trial and error is getting me further away from a solution.I've attached some examples of the design work I'm going for since I want to achieve a similar modular component to build the structure out of and hence need to fix this mesh problem.
It'd be great to have this sorted over the weekend, but figuring this out in general would be awesome.Cheers.
…