in green in the below screenshot) and it was fine in generating different stochastic aggregation outputs but when I shift to a slightly more complex geometry (in blue in below screenshot), the component has an error that reads " could not place 28 parts".
I've attached the .gh file with internalized data, any help would be awesome!
Thanks in advance (:
…
Added by vhwt to Wasp at 10:32pm on September 22, 2021
(http://www.food4rhino.com/app/meshedit)
Weaverbird (http://www.giuliopiacentino.com/weaverbird/)
Make sure to install them before opening the example file.
For the Screenshot (27) error, make sure all of the *.dll files that came in the zip archive are unblocked and that you are using the Heron 0.2.0.0 GHA. You may have to replace the component with a new one from the Heron menu.…
urface,like
surface0 had 41 floors
surface1 had 28 floors
surface2 had 21 floors
I tried to change the data matching of the <move> component but still can't make the result that I want.
beside that, are there any component can let the overlay boxes can separate like this:
i make it manually by bake and move and bake and move..............
please forgive my broken english.
thanks
my definition
MASS%20STUDY-1.gh…
pen Brep"; I didn't know it worked on flat surfaces. And I think it's only fair to include in your benchmark the considerable time 'SUnion' takes in this example: 21.9 seconds for 121 rings and likely much more with 400 or 1,000+ rings.
Then I noticed the pattern doesn't match. Checked the circles and they are the same. The distance between them, however, is different: 7 instead of 6. When I change that value to 6, the Python fails badly. All the holes and gaps are gone, which destroys the pattern:
I can't do the "two phase" approach on an 11 X 11 grid, but I can do 6 X 6 and 2 X 2 to get a 12 X 12 grid (40 'SUnion' operations) in 28 seconds total. That beats your benchmark of ~37 seconds for an 11 X 11 grid, if you include the 'SUnion' in your code.
…
this common installation problem please find a tested remedy shared by one of the group members:
Comment by Iman Sheikhansari on August 26, 2019 at 8:33amDelete Comment
HiIf you are encountering a problem with rhino 6 versions don't worryFollow these steps.1. Download SYNTACTIC from https://sites.google.com/site/pirouznourian/syntactic-design2. Install it and go to the installation folder, Drag & drop SYNTACTIC(green one) over your grasshopper canvas.3. Close your rhino and reopen it. 4. Type GrasshopperDeveloperSettings5. Tick the Memory load *.GHA assemblies using COFF byte arrays option6. Run grasshopper and enjoy plugin
I hope this helps,
Best regards,
Pirouz
…
ctorial component to go to higher factorials/permutations just to determine easily permutations. For instance I have 30 tile colors and I wanted to see their permutations quickly, I realize I can use 30*29*28 etc but I thought I could do this using the simple definition that one can see in the pic.
RM
…
e structure systems. It presents an algorithmic process where the initial generative rule is based on the growth of Cellular Automata (CA). Digital Fabrication techniques will be used for prototyping. Theoretical lectures about Cellular Automata, Generative design and fabrication techniques will be presented .
Duration : 21 June. – 28 June. 2013 from 10 am to 6 pm Location : ENCODE Studio Address: 2 Wataneya buildings , 14 May Bridge , Smouha , Floor 1 , Apartment 106 Tel: 03-3823637 Mob: 0100-9879995 Email: encodestudio.mail@gmail.com Website: www.encodestudio.net for more information and registration please fill the following form : https://docs.google.com/forms/d/1FC9-CIDsNuzMkmu3Rubj45_7zTBb6YB3OfYnEA9xOMk/viewform?edit_requested=true Attendance Confirmation email will be sent to confirm availability…
NONE, in SIZING:PARAMETERS". I'm not sure of where to start in troubleshooting this. I've attached the file.
Thank you,
See the errors and warnings below:
{0;0;0}
0. Current document units is in Meters
1. Conversion to Meters will be applied = 1.000
2. [1 of 8] Writing simulation parameters...
3. [2 of 8] Writing context surfaces...
4. [2 of 8] Writing context surfaces...
5. [3 of 8] Writing geometry...
6. [4 of 8] Writing Electric Load Center - Generator specifications ...
7. [5 of 8] Writing materials and constructions...
8. [6 of 8] Writing schedules...
9. [7 of 8] Writing loads and ideal air system...
10. [8 of 8] Writing outputs...
11. ...
... idf file is successfully written to : R:\Green\SuRG\Building_Performance_Analysis\2016_analysis_studies\Energy_Analysis_Comparison\Honeybee_+_Ladybug\tutorial01\EnergyPlus\tutorial01.idf
12.
13. Analysis is running!...
14. ...
...
Done! Read below for errors and warnings:
15.
16. Program Version,EnergyPlus, Version 8.5.0-c87e61b44b, YMD=2016.10.31 11:39,IDD_Version 8.5.0
17.
18. ************* IDF Context for following error/warning message:
19.
20. ************* Note -- lines truncated at 300 characters, if necessary...
21.
22. ************* 24 Sizing:Parameters,
23.
24. ************* Only last 1 lines before error line shown.....
25.
26. ************* 25 None, !- Heating Sizing Factor
27.
28. ** Severe ** IP: IDF line~25 Invalid Number in Numeric Field#1 (Heating Sizing Factor), value=NONE, in SIZING:PARAMETERS
29.
30. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.
31.
32. ** ~~~ ** Possible Invalid Numerics or other problems
33.
34. ** Fatal ** IP: Errors occurred on processing IDF file. Preceding condition(s) cause termination.
35.
36. ...Summary of Errors that led to program termination:
37.
38. ..... Reference severe error count=1
39.
40. ..... Last severe error=IP: IDF line~
, value=NONE, in SIZING:PARAMETERS
41.
42. ************* Warning: Node connection errors not checked - most system input has not been read (see previous warning).
43.
44. ************* Fatal error -- final processing. Program exited before simulations began. See previous error messages.
45.
46. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.
47.
48. ************* EnergyPlus Sizing Error Summary. During Sizing: 0 Warning; 0 Severe Errors.
49.
50. ************* EnergyPlus Terminated--Fatal Error Detected. 1 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 9.34sec
51.…