nother nurbs surface that is built from control points extracted from the other two (3 three rows of control points shown in the picture are the ones I would like to use).
When I try to use the "Surface from Points" component, however, I cannot get the surface to generate properly. From my understanding of previous discussions on this forum, the U parameter should be U+1 which in my case would be 11. No parameter from 0-11 is producing the results I'm looking for, however.
My attempted solution is attached. I get the feeling the solution will be quite straightforward...
Thanks,
Austin
…
you post a screenshot of what the message coming from its readMe! output looks like?2) Close your Grasshopper and Rhino.3) Download "Revo Uninstaller Pro" from here. It is free for first 30 days, which is what we need.4) Right click on the RevoUninProSetup.exe and check if the file is blocked. If it is, unblock it.5) Run the RevoUninProSetup.exe file and install "Revo Uninstaller Pro".6) Uninstall "MapWinGIS" with "Revo Uninstaller Pro". It is important that "Revo Uninstaller Pro" deletes not only files from MapWinGIS installation folder, but also all other leftovers (as registry inputs). Here is a small tutorial on how to do that. Watch it from 6:10 till the end.7) Restart your PC8) When your Windows boots up, make sure that you are logged in as Administrator!9) In your Start menu's search box type: "UAC", which will find your User Account Control Settings. Click on it, and a new window will open. Set the bar on the left to "Never notify".10) Turn off your Windows Firewall.11) Then turn off your custom Firewall (in case you have another one, besides standard Windows Firewall).12) Completely turn off your Antivirus.13) Download again the MapWinGIS-only-v4.9.4.2-x64.exe.exe file from here.14) Right click on the MapWinGIS-only-v4.9.4.2-x64.exe file and see if it is blocked. If it is, unblock it.15) Right click on MapWinGIS-only-v4.9.4.2-x64.exe file and choose: "Run as"... Administrator.16) One the installation preparation steps start, choose "Full installation". Wait for the MapWinGIS installation to finish.17) Right-click on "Rhino 5" icon and then choose: "Run as administrator".18) Open the the ironpython_admin.gh file again, and again post a screenshot of the message coming from its readMe! output.19) Drop the "Gismo Gismo" component to Grasshopper canvas. Post a screenshot of the message coming out from its readMe! output.
So we will need in total three screenshots of the readMe! output messages.
Thank you once again for being patient, and sorry for the large number of steps.…
Added by djordje to Gismo at 1:52am on April 9, 2017
be done easier, but later on the geometry will change and therefore this seems the better option. But coming back to the problem
First, there were some problems concerning the zone, although it seems solved still the “runenergysimulation” gives the following warning:
1. The simulation has not run correctly because of this severe error:
** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature
Do one of you know what went wrong? It probably will solve most of it.
Second, “set Zone Thresholds” gives the following warning:
1. Solution exception:global name 'maxHumidity_' is not defined
However, the component is missing the max humidity input on the list, has this to do something with the error?
All the components are up to date.
I hope it will be an easy fix.
Gr Lars
“set Zone Thresholds” runtime error
{0;0;0}0. Runtime error (UnboundNameException): global name 'maxHumidity_' is not defined1. Traceback: line 80, in checkTheInputs, "<string>" line 282, in script
"runenergysimulation” report
{0;0}0. Current document units is in Meters1. Conversion to Meters will be applied = 1.0002. TypeError('Waarde kan niet null zijn.\r\nParameternaam: source',)3. Failed to copy the object. Returning the original objects...This can cause strange behaviour!4. [1 of 8] Writing simulation parameters...5. [2 of 8] No context surfaces...6. [3 of 8] Writing geometry...7. [4 of 8] Writing Electric Load Center - Generator specifications ...8. [5 of 8] Writing materials and constructions...9. [6 of 8] Writing schedules...10. [7 of 8] Writing loads and ideal air system...11. [8 of 8] Writing outputs...12. ...... idf file is successfully written to : c:\ladybug\unnamed\EnergyPlus\unnamed.idf13. 14. Analysis is running!...15. c:\ladybug\unnamed\EnergyPlus\eplusout.csv16. ......
Done! Read below for errors and warnings:
17. 18. Program Version,EnergyPlus, Version 8.3.0-6d97d074ea, YMD=2016.03.02 20:55,IDD_Version 8.3.019. 20. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.21. 22. ************* Beginning Zone Sizing Calculations23. 24. ** Warning ** GetInternalHeatGains: People="CLASSROOMOFFICEPEOPLE", Activity Level Schedule Name values25. 26. ** ~~~ ** fall outside typical range [70,1000] W/person for Thermal Comfort Reporting.27. 28. ** ~~~ ** Odd comfort values may result; Schedule="SCHOCCUPANCYSCHEDULE".29. 30. ** ~~~ ** Entered min/max range=[0.0,1.0] W/person.31. 32. ** Warning ** Calculated design heating load for zone=CLASSROOM is zero.33. 34. ** ~~~ ** Check Sizing:Zone and ZoneControl:Thermostat inputs.35. 36. ** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature37. 38. ** ~~~ ** ...check zone thermostat set point and design supply air temperatures39. 40. ** ~~~ ** ...zone name = CLASSROOM41. 42. ** ~~~ ** ...design sensible cooling load = 25499.10 W43. 44. ** ~~~ ** ...thermostat set point temp = 0.000 C45. 46. ** ~~~ ** ...zone temperature = 15.334 C47. 48. ** ~~~ ** ...supply air temperature = 15.000 C49. 50. ** ~~~ ** ...temperature difference = -0.33433 C51. 52. ** ~~~ ** ...calculated volume flow rate = 197273.21341 m3/s53. 54. ** ~~~ ** ...calculated mass flow rate = 237634.19357 kg/s55. 56. ** Warning ** ManageSizing: For a plant sizing run, there must be at least 1 Sizing:Plant object input. SimulationControl Plant Sizing option ignored.57. 58. ************* Testing Individual Branch Integrity59. 60. ************* All Branches passed integrity testing61. 62. ************* Testing Individual Supply Air Path Integrity63. 64. ************* All Supply Air Paths passed integrity testing65. 66. ************* Testing Individual Return Air Path Integrity67. 68. ************* All Return Air Paths passed integrity testing69. 70. ************* No node connection errors were found.71. 72. ************* Beginning Simulation73. 74. ************* Simulation Error Summary *************75. 76. ** Warning ** The following Report Variables were requested but not generated77. 78. ** ~~~ ** because IDF did not contain these elements or misspelled variable name -- check .rdd file79. 80. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL COOLING ENERGY, Frequency=Hourly81. 82. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL HEATING ENERGY, Frequency=Hourly83. 84. ************* Key=*, VarName=CHILLER ELECTRIC ENERGY, Frequency=Hourly85. 86. ************* Key=*, VarName=BOILER HEATING ENERGY, Frequency=Hourly87. 88. ************* Key=*, VarName=FAN ELECTRIC ENERGY, Frequency=Hourly89. 90. ************* Key=*, VarName=ZONE VENTILATION FAN ELECTRIC ENERGY, Frequency=Hourly91. 92. ************* Key=*, VarName=EARTH TUBE FAN ELECTRIC ENERGY, Frequency=Hourly93. 94. ************* Key=*, VarName=PUMP ELECTRIC ENERGY, Frequency=Hourly95. 96. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT LOSS ENERGY, Frequency=Hourly97. 98. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT GAIN ENERGY, Frequency=Hourly99. 100. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE COOLING ENERGY, Frequency=Hourly101. 102. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE HEATING ENERGY, Frequency=Hourly103. 104. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.105. 106. ************* EnergyPlus Sizing Error Summary. During Sizing: 3 Warning; 1 Severe Errors.107. 108. ************* EnergyPlus Completed Successfully-- 5 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 4.65sec109.…
ample grid size, 'Scale (Sample)'. Set at 0.5, that's 845 X 612 or 517,140 points. Lofting 1-Degree nurbs curves took 17 minutes! Results look good to me. 2-Degree curves loft in 7 seconds, not as "high def" (sharp) as 1-Degree, which are close to polylines.
'Flip' gives curves and loft at 90 degrees.
Code won't load because with Photoshopped image (trimming 'Levels' ), it's 11 MBytes.…
Added by Joseph Oster at 11:58am on October 25, 2015
s than 40% on average.2. 8gb usage is steady at 28% 3. I've been now looking at 2 blank white screen, in both Rhino and Grasshopper for well over 20 min. finally I went for a walk at 10:25am, (its a beautiful day why waste it looking at nonexistent calculations, It would help if there was a timing function in the code that would let me know how long the calculations were going to take, came back 11:25am still no results. Had to Quit Rhino in the Start manager.
I have used all sorts of window programs for well over 25 years. Rhino and Grasshopper are the only 2 programs that I have ever seen that show totally white screens in their operating windows :(
…
right? When the dataTree is this simple its not really a problem, but when it grows and I want to be able to refer to a specific GH branch e.g. {11;320} and I need to read this specific branch in Python? How do I do this?
I know that there is the function tree.Path(x) this will give me the GH Path, but how do I figure out what x needs to be? I guess there must be a simple answer :).
Thanks Rasmus…
Added by Rasmus Holst at 1:24am on October 14, 2013
ed according to list C.
I tried replace members, but it consists of geometry, so it doesn't worked.
In list C I filtered all the indices that need to be replaced.
All items in {0;0} from C need to be replaced by List B {0;0}
All items in {0;1} from C need to be replaced by List B {0;1}
And so on...
In the end everything needs to be fed into a orient component.
G is the geometry behind list B
A is the new list (but I don't know how to create)
B is the list A of all 60 panels
To wrap up the question:
I need to have entry 1 from list B in a new list on position: 0 1 2 3 5 6 7 10 11 12 15 16 21
I need to have entry 2 from list B in the same new list on position: 4 8 9 13 14 etc. etc. etc.
I wonder how I can do this :) Thanks in advance!
…