elementary; you can see how I picked out 2 of the pentagon's sides individually. This is by far not the best way to do this.
The proper way is to use a an index pattern to pick out sides 1 & 2, 2 & 3, 3 & 4, 4 & 5, and 5 & 1, and then pass these pairs to the fillet routine. There is a way to do this but I couldn't remember the method. …
EC
1. Between hours 1:00 to 24:002. Current document units is in Meters3. Conversion to Meters will be applied = 1.0004. [1 of 7] Writing simulation parameters...5. [2 of 6] No context surfaces...6. [3 of 6] Writing geometry...7. [4 of 6] Writing materials and constructions...8. [5 of 7] Writing schedules...9. [6 of 7] Writing loads and ideal air system...10. [7 of 7] Writing outputs...11. ...... idf file is successfully written to : c:\ladybug\Freeformtower_IDF\EnergyPlus\Freeformtower_IDF.idf12. 13. Analysis is running!...14. ......
Done! Read below for errors and warnings:
15. 16. Program Version,EnergyPlus-Windows-64 8.1.0.009, YMD=2015.04.04 23:39,IDD_Version 8.1.0.00917. 18. ************* IDF Context for following error/warning message:19. 20. ************* Note -- lines truncated at 300 characters, if necessary...21. 22. ************* 577 Zone,23. 24. ************* Only last 1 lines before error line shown.....25. 26. ************* 578 Freeformbuilding27. 28. ** Warning ** IP: IDF line~578 Comma being inserted after:" Freeformbuilding" in Object=ZONE29. 30. ** Severe ** Out of range value Numeric Field#5 (Type), value=0.00000, range={>=1 and <=1}, in ZONE=FREEFORMBUILDING31. 32. ************* IDF Context for following error/warning message:33. 34. ************* Note -- lines truncated at 300 characters, if necessary...35. 36. ************* 586 BuildingSurface:Detailed,7341.
…
have 2 different lengths.Ex: 0, 2, 4 and 6 gets one length, while section 1, 3, 5 and 7 gets anotherAnyone here that has a good solution for this?
Sincerely,
Brage…
or each branch goes to col 1, element 2 to col 2 and so on. The issue I am having is how to deal with branches that have less than 5 elements. Notice how in the attachment the number 8 is at row 2 where I want it to be in row 3.…
Added by jon kontuly at 1:03pm on September 30, 2014
ow do you sort data trees with distinctive number of list items in each branch?
In this example, there are 161 branches with three distinctive number of list items, 3, 4, and 5. I want to know if there is another way to sort out this data tree into this way: 3 vertices {0;0}, {0;1}, {0;2],...4 vertices {1;0}, {1;1}, {1;2},... 5 vertices {2;0}, {2;1}, {2;2},...
2. Is there a way to sort our surfaces based on number of distinctive list items automatically? For example, if there are surfaces with 3, 4, 5, 6, and 7 vertices, I want to make five branches with the same number of vertices automatically.
I hope my questions make sense...
Thank you!
Dongyeop …
Added by Dongyeop Lee at 12:14pm on October 3, 2016
NONE, in SIZING:PARAMETERS". I'm not sure of where to start in troubleshooting this. I've attached the file.
Thank you,
See the errors and warnings below:
{0;0;0}
0. Current document units is in Meters
1. Conversion to Meters will be applied = 1.000
2. [1 of 8] Writing simulation parameters...
3. [2 of 8] Writing context surfaces...
4. [2 of 8] Writing context surfaces...
5. [3 of 8] Writing geometry...
6. [4 of 8] Writing Electric Load Center - Generator specifications ...
7. [5 of 8] Writing materials and constructions...
8. [6 of 8] Writing schedules...
9. [7 of 8] Writing loads and ideal air system...
10. [8 of 8] Writing outputs...
11. ...
... idf file is successfully written to : R:\Green\SuRG\Building_Performance_Analysis\2016_analysis_studies\Energy_Analysis_Comparison\Honeybee_+_Ladybug\tutorial01\EnergyPlus\tutorial01.idf
12.
13. Analysis is running!...
14. ...
...
Done! Read below for errors and warnings:
15.
16. Program Version,EnergyPlus, Version 8.5.0-c87e61b44b, YMD=2016.10.31 11:39,IDD_Version 8.5.0
17.
18. ************* IDF Context for following error/warning message:
19.
20. ************* Note -- lines truncated at 300 characters, if necessary...
21.
22. ************* 24 Sizing:Parameters,
23.
24. ************* Only last 1 lines before error line shown.....
25.
26. ************* 25 None, !- Heating Sizing Factor
27.
28. ** Severe ** IP: IDF line~25 Invalid Number in Numeric Field#1 (Heating Sizing Factor), value=NONE, in SIZING:PARAMETERS
29.
30. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.
31.
32. ** ~~~ ** Possible Invalid Numerics or other problems
33.
34. ** Fatal ** IP: Errors occurred on processing IDF file. Preceding condition(s) cause termination.
35.
36. ...Summary of Errors that led to program termination:
37.
38. ..... Reference severe error count=1
39.
40. ..... Last severe error=IP: IDF line~
, value=NONE, in SIZING:PARAMETERS
41.
42. ************* Warning: Node connection errors not checked - most system input has not been read (see previous warning).
43.
44. ************* Fatal error -- final processing. Program exited before simulations began. See previous error messages.
45.
46. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.
47.
48. ************* EnergyPlus Sizing Error Summary. During Sizing: 0 Warning; 0 Severe Errors.
49.
50. ************* EnergyPlus Terminated--Fatal Error Detected. 1 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 9.34sec
51.…