the points with panels.
I am wondering if there is a simpler way to do this so that I don't have to make 100 sections for 100 points?
I attached a small chunk of the file so far to get an idea of what I am doing currently.
Any advice would be greatly appreciated thanks!…
with 10 ordered curves. These in turn are to be interated in a move slider( 10 vectors).
As I plug these 3 new grafts in the move slider though, these curves all iterated 10 times (100 curves total) instead of being lifted one at a time.
…
be done easier, but later on the geometry will change and therefore this seems the better option. But coming back to the problem
First, there were some problems concerning the zone, although it seems solved still the “runenergysimulation” gives the following warning:
1. The simulation has not run correctly because of this severe error:
** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature
Do one of you know what went wrong? It probably will solve most of it.
Second, “set Zone Thresholds” gives the following warning:
1. Solution exception:global name 'maxHumidity_' is not defined
However, the component is missing the max humidity input on the list, has this to do something with the error?
All the components are up to date.
I hope it will be an easy fix.
Gr Lars
“set Zone Thresholds” runtime error
{0;0;0}0. Runtime error (UnboundNameException): global name 'maxHumidity_' is not defined1. Traceback: line 80, in checkTheInputs, "<string>" line 282, in script
"runenergysimulation” report
{0;0}0. Current document units is in Meters1. Conversion to Meters will be applied = 1.0002. TypeError('Waarde kan niet null zijn.\r\nParameternaam: source',)3. Failed to copy the object. Returning the original objects...This can cause strange behaviour!4. [1 of 8] Writing simulation parameters...5. [2 of 8] No context surfaces...6. [3 of 8] Writing geometry...7. [4 of 8] Writing Electric Load Center - Generator specifications ...8. [5 of 8] Writing materials and constructions...9. [6 of 8] Writing schedules...10. [7 of 8] Writing loads and ideal air system...11. [8 of 8] Writing outputs...12. ...... idf file is successfully written to : c:\ladybug\unnamed\EnergyPlus\unnamed.idf13. 14. Analysis is running!...15. c:\ladybug\unnamed\EnergyPlus\eplusout.csv16. ......
Done! Read below for errors and warnings:
17. 18. Program Version,EnergyPlus, Version 8.3.0-6d97d074ea, YMD=2016.03.02 20:55,IDD_Version 8.3.019. 20. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.21. 22. ************* Beginning Zone Sizing Calculations23. 24. ** Warning ** GetInternalHeatGains: People="CLASSROOMOFFICEPEOPLE", Activity Level Schedule Name values25. 26. ** ~~~ ** fall outside typical range [70,1000] W/person for Thermal Comfort Reporting.27. 28. ** ~~~ ** Odd comfort values may result; Schedule="SCHOCCUPANCYSCHEDULE".29. 30. ** ~~~ ** Entered min/max range=[0.0,1.0] W/person.31. 32. ** Warning ** Calculated design heating load for zone=CLASSROOM is zero.33. 34. ** ~~~ ** Check Sizing:Zone and ZoneControl:Thermostat inputs.35. 36. ** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature37. 38. ** ~~~ ** ...check zone thermostat set point and design supply air temperatures39. 40. ** ~~~ ** ...zone name = CLASSROOM41. 42. ** ~~~ ** ...design sensible cooling load = 25499.10 W43. 44. ** ~~~ ** ...thermostat set point temp = 0.000 C45. 46. ** ~~~ ** ...zone temperature = 15.334 C47. 48. ** ~~~ ** ...supply air temperature = 15.000 C49. 50. ** ~~~ ** ...temperature difference = -0.33433 C51. 52. ** ~~~ ** ...calculated volume flow rate = 197273.21341 m3/s53. 54. ** ~~~ ** ...calculated mass flow rate = 237634.19357 kg/s55. 56. ** Warning ** ManageSizing: For a plant sizing run, there must be at least 1 Sizing:Plant object input. SimulationControl Plant Sizing option ignored.57. 58. ************* Testing Individual Branch Integrity59. 60. ************* All Branches passed integrity testing61. 62. ************* Testing Individual Supply Air Path Integrity63. 64. ************* All Supply Air Paths passed integrity testing65. 66. ************* Testing Individual Return Air Path Integrity67. 68. ************* All Return Air Paths passed integrity testing69. 70. ************* No node connection errors were found.71. 72. ************* Beginning Simulation73. 74. ************* Simulation Error Summary *************75. 76. ** Warning ** The following Report Variables were requested but not generated77. 78. ** ~~~ ** because IDF did not contain these elements or misspelled variable name -- check .rdd file79. 80. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL COOLING ENERGY, Frequency=Hourly81. 82. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL HEATING ENERGY, Frequency=Hourly83. 84. ************* Key=*, VarName=CHILLER ELECTRIC ENERGY, Frequency=Hourly85. 86. ************* Key=*, VarName=BOILER HEATING ENERGY, Frequency=Hourly87. 88. ************* Key=*, VarName=FAN ELECTRIC ENERGY, Frequency=Hourly89. 90. ************* Key=*, VarName=ZONE VENTILATION FAN ELECTRIC ENERGY, Frequency=Hourly91. 92. ************* Key=*, VarName=EARTH TUBE FAN ELECTRIC ENERGY, Frequency=Hourly93. 94. ************* Key=*, VarName=PUMP ELECTRIC ENERGY, Frequency=Hourly95. 96. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT LOSS ENERGY, Frequency=Hourly97. 98. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT GAIN ENERGY, Frequency=Hourly99. 100. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE COOLING ENERGY, Frequency=Hourly101. 102. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE HEATING ENERGY, Frequency=Hourly103. 104. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.105. 106. ************* EnergyPlus Sizing Error Summary. During Sizing: 3 Warning; 1 Severe Errors.107. 108. ************* EnergyPlus Completed Successfully-- 5 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 4.65sec109.…
tober 2023 - 03 October 2024 Registration Deadline is 15 April 2023
Avenue :
AANT, The Academy of Art and New Technology - Rome Number of students:
20 – 30 students Official language:
English Duration:
One year of 1180 total hours; 600 for courses and laboratories + 480 for internship + 100 for Final project Place: 9 months at the Academy of Art and New Technology in Rome and 3 months Internship worldwide Professors and Tutors from
AANT - Rome, politecnico di Milano- Italy, American University of Cairo, Egypt, Beirut Arab University- Lebanon and , SAS-UNICAM-Italy Fees:
7400 Euros
…
(without the flaps on the edge). 1. How can I make this "piece" behave like a segment with multiple folds? 2. How can I add more of the same segments (join them on the sides) in order to create a closed object? 3. I would also like to be able to change the number of border edges as well and to be able to control the position of those points in order to make differently shaped "planar pieces" and different objects in the end.
All ideas are appreciated. Thank you. Jiri…
postion i j k;
value, state:
1:get.grid3d.cell i, j, k, [index]);
index: Each 3D grid cell has up to 3 different slots for storing values.
state could be:
1 Visible and selected
0 Visible but not selected
-99 Disabled
-100 Hidden
-100 Hidden and selected
best to]…
t in space, (the sun)
Then draw lines from each area centroid of the volumes to the sun.
I then wish each volume to be extruded to a certain height (5m) however where ever a line intersects with a volume I wish that volume to cease extruding at that point
It’s a concept I'm working on which I'm able to do on a small scale however when I add more volumes the scripts get very heavy, complex and I can’t help but feel there is a much simpler way.
What I'm interested in knowing is if:- There a way to map or re map an intersecting line with a volume If I simply put all the volumes and lines in a list of data.
I.e if line – 59 intersects with volume 33 extrude volume 33 to point 59. essentially I need grasshopper to know which lines are being intersected and extrude the volumes accordingley.
Really hope someone out there can interpret my text and possible help.
Thanks in advance.
Rich.…
cy of design communication and the control of information-flow are as important as the creativity of ideas. In response to the concurrent digital evolution emerging in the architectural industry world-wide, the Faculty of Architecture at The University of Hong Kong will host a two week intensive summer program named Digital Practice.Led by professors from The University of Hong Kong, as well as invited practitioners with expertise in practice of cutting edge digital techniques, the program offers participants opportunities to experience applications of computational tools during different stages of an architectural project, i.e. concept design, form finding and optimization, delivery, management and communication of design information under the team-based working environment. By learning advanced computational techniques through case studies in the context of Hong Kong, participants are expected to go beyond the conventional perception of technology, considering users and tools as a feedback-based entity instead of a dichotomy. The program, which is taught in English, includes a series of evening lectures related delivered by teaching staff and invited local architects.對於高品質的建築專案,創意之外,專案過程中高效的設計資訊管理和交流成為項目設計深化和實施必不可少的環節。今天,數字化技術不但改變了建築師的繪圖工具,影響了設計的過程,而且提供了工程建造和管理實施的更有效、更高效的手段。針對建築的數位化演進,香港大學建築學院將於2011年暑假期間,在香港大學建築學院舉辦“數位化實踐”國際研習班。在香港大學建築學院教授及有著相關豐富經驗的外聘實踐建築師的指導下,學員將有機會體驗在專案的不同階段(如概念設計、設計形式的生成、優化,設計資訊的管理和交流),如何有效地應用各種運算智慧化技術(從設計的數位化生成和建築資訊類比到物理模型),提升設計實施的品質,增加設計團隊對於方案的控制。我們將挑戰對於“技術”的傳統認知,即相對於使用者它不僅是工具,更是與使用者互動的媒介,二者形成一個有機的合體。研習班期間會安排系列講座,展現數位化技術在實踐工程中的廣泛應用。…