ecember 2017 from 18:30 until 20:30. We will have presentations from Heatherwick Studio and AKT II.
Please visit the following page for more details and registration: http://simplyrhino.co.uk/events/upcoming-events/grasshopper-uk-ugm-2017
Heatherwick studio will present two projects covering the topic of designing, making and collaborating through computational tools. Heatherwick’s Geometry and Computational Design team will go through the computational processes behind design and making in the studio concentrating on two projects, Vessel in New York with a focus on driving the geometry and Al Fayah Park in Abu Dhabi with a focus on Form Finding and working with collaborative tools.
AKT II's presentation will explore a series of examples where this new approach was experimented, tested and improved, the Al Fayah Park in collaboration with Heatherwick studio and the 2016 Serpentine Pavilion with BIG, and more.
We're looking forward to seeing you all again!
Many thanks,
Paul and Arthur
…
heating? Or cooling?)
What if you have 20C? You need to heat to 24-26?
What if you have 28? Then you cool to 24-26?
Something is missing here ...
Or am i wrong? (In this case i don't understand the logic).
Besides that, you are simulating 3 zones instead of 1. Your conncetions of all the HB_setEPZoneSchedules to the HB_setEPIdealAir is causing this. Messy ... a little bit.
-A.…
: Castellano
Horarios
Básico - miércoles
18.30 - 21.30 h
Avanzado - miércoles
15.00 - 18.00 h
Una vez finalizado el curso, el alumno podrá solicitar un diploma acreditativo del mismo.
Normativa: http://daetsam.aq.upm.es/servicios/cursos/informacion
Información cursos: http://daetsam.aq.upm.es/servicios/cursos/primavera2014
Métodos de pago: http://daetsam.aq.upm.es/noticias/2014/02/16/cursos-primavera-2014-aplicaciones-informaticas-e-idiomas
…
NONE, in SIZING:PARAMETERS". I'm not sure of where to start in troubleshooting this. I've attached the file.
Thank you,
See the errors and warnings below:
{0;0;0}
0. Current document units is in Meters
1. Conversion to Meters will be applied = 1.000
2. [1 of 8] Writing simulation parameters...
3. [2 of 8] Writing context surfaces...
4. [2 of 8] Writing context surfaces...
5. [3 of 8] Writing geometry...
6. [4 of 8] Writing Electric Load Center - Generator specifications ...
7. [5 of 8] Writing materials and constructions...
8. [6 of 8] Writing schedules...
9. [7 of 8] Writing loads and ideal air system...
10. [8 of 8] Writing outputs...
11. ...
... idf file is successfully written to : R:\Green\SuRG\Building_Performance_Analysis\2016_analysis_studies\Energy_Analysis_Comparison\Honeybee_+_Ladybug\tutorial01\EnergyPlus\tutorial01.idf
12.
13. Analysis is running!...
14. ...
...
Done! Read below for errors and warnings:
15.
16. Program Version,EnergyPlus, Version 8.5.0-c87e61b44b, YMD=2016.10.31 11:39,IDD_Version 8.5.0
17.
18. ************* IDF Context for following error/warning message:
19.
20. ************* Note -- lines truncated at 300 characters, if necessary...
21.
22. ************* 24 Sizing:Parameters,
23.
24. ************* Only last 1 lines before error line shown.....
25.
26. ************* 25 None, !- Heating Sizing Factor
27.
28. ** Severe ** IP: IDF line~25 Invalid Number in Numeric Field#1 (Heating Sizing Factor), value=NONE, in SIZING:PARAMETERS
29.
30. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.
31.
32. ** ~~~ ** Possible Invalid Numerics or other problems
33.
34. ** Fatal ** IP: Errors occurred on processing IDF file. Preceding condition(s) cause termination.
35.
36. ...Summary of Errors that led to program termination:
37.
38. ..... Reference severe error count=1
39.
40. ..... Last severe error=IP: IDF line~
, value=NONE, in SIZING:PARAMETERS
41.
42. ************* Warning: Node connection errors not checked - most system input has not been read (see previous warning).
43.
44. ************* Fatal error -- final processing. Program exited before simulations began. See previous error messages.
45.
46. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.
47.
48. ************* EnergyPlus Sizing Error Summary. During Sizing: 0 Warning; 0 Severe Errors.
49.
50. ************* EnergyPlus Terminated--Fatal Error Detected. 1 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 9.34sec
51.…
思った感じになりません。
balls の代わりにplanarカーブを直接入れてみましたがエラーが出ます。
ファンクションにしてみたところ、forループので作った数値が反映されていません。
ファンクションのインスタンス?を出力していないと思い上記のようにしましたがエラーが出てしまいます。
以上の事から自分の認識が正しいのかよくわからなくなりました・・・
python自体の深いところをわかっているわけではないので余計こんがらがりました。
そこで、for b in ballsはどのような条件または使い方であれば使えるのでしょうか?
そして、上記のように別のオブジェクトに対しての使い方はどのようにすればできるのでしょうか?
2:同じファンクション内のdist = rs.Distance(self.pos,b.pos)についてですが
この文章も for b in balls によってbはBallのインスタンスであると定義?されたためb.posがbの位置であると分かるのでしょうか?
pythonは定義しなくても動いてしまうのでどのような時に使えるのか文章見ただけではよくわかりません・・・
大変細かいことかもしれませんが、よりpythonをしっかりと理解するためにも、どなたかわかる方ご教授いただけると幸いです。…