I am not sure if that's the file. Horster camera control has a tab with 3 components in my pc. I cant recall if horster tools had bundled camera controls with other tools.
s than 40% on average.2. 8gb usage is steady at 28% 3. I've been now looking at 2 blank white screen, in both Rhino and Grasshopper for well over 20 min. finally I went for a walk at 10:25am, (its a beautiful day why waste it looking at nonexistent calculations, It would help if there was a timing function in the code that would let me know how long the calculations were going to take, came back 11:25am still no results. Had to Quit Rhino in the Start manager.
I have used all sorts of window programs for well over 25 years. Rhino and Grasshopper are the only 2 programs that I have ever seen that show totally white screens in their operating windows :(
…
NONE, in SIZING:PARAMETERS". I'm not sure of where to start in troubleshooting this. I've attached the file.
Thank you,
See the errors and warnings below:
{0;0;0}
0. Current document units is in Meters
1. Conversion to Meters will be applied = 1.000
2. [1 of 8] Writing simulation parameters...
3. [2 of 8] Writing context surfaces...
4. [2 of 8] Writing context surfaces...
5. [3 of 8] Writing geometry...
6. [4 of 8] Writing Electric Load Center - Generator specifications ...
7. [5 of 8] Writing materials and constructions...
8. [6 of 8] Writing schedules...
9. [7 of 8] Writing loads and ideal air system...
10. [8 of 8] Writing outputs...
11. ...
... idf file is successfully written to : R:\Green\SuRG\Building_Performance_Analysis\2016_analysis_studies\Energy_Analysis_Comparison\Honeybee_+_Ladybug\tutorial01\EnergyPlus\tutorial01.idf
12.
13. Analysis is running!...
14. ...
...
Done! Read below for errors and warnings:
15.
16. Program Version,EnergyPlus, Version 8.5.0-c87e61b44b, YMD=2016.10.31 11:39,IDD_Version 8.5.0
17.
18. ************* IDF Context for following error/warning message:
19.
20. ************* Note -- lines truncated at 300 characters, if necessary...
21.
22. ************* 24 Sizing:Parameters,
23.
24. ************* Only last 1 lines before error line shown.....
25.
26. ************* 25 None, !- Heating Sizing Factor
27.
28. ** Severe ** IP: IDF line~25 Invalid Number in Numeric Field#1 (Heating Sizing Factor), value=NONE, in SIZING:PARAMETERS
29.
30. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.
31.
32. ** ~~~ ** Possible Invalid Numerics or other problems
33.
34. ** Fatal ** IP: Errors occurred on processing IDF file. Preceding condition(s) cause termination.
35.
36. ...Summary of Errors that led to program termination:
37.
38. ..... Reference severe error count=1
39.
40. ..... Last severe error=IP: IDF line~
, value=NONE, in SIZING:PARAMETERS
41.
42. ************* Warning: Node connection errors not checked - most system input has not been read (see previous warning).
43.
44. ************* Fatal error -- final processing. Program exited before simulations began. See previous error messages.
45.
46. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.
47.
48. ************* EnergyPlus Sizing Error Summary. During Sizing: 0 Warning; 0 Severe Errors.
49.
50. ************* EnergyPlus Terminated--Fatal Error Detected. 1 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 9.34sec
51.…
home PC and it worked without any issues.
Do you have Administrator privileges on your PC?
Is it possible that you do this:1) Set all _runIt inputs in your tuc_terrain.gh file to False.2) Save an close the tuc_terrain.gh file.3) Delete your "c:/gismo" folder4) Open again your tuc_terrain.gh file in Grasshopper.5) Run the "OSM shapes" component by setting its _runIt input to True.6) If you again get the "Invalid shapes" warning, then set the _runIt input of the "OSM shapes" component to False.7) Wait at least a couple of seconds (let' say 6 or 7 seconds)!8) Set the _runIt input of the "OSM shapes" component to True again.
What happens then?…
Added by djordje to Gismo at 1:45am on August 3, 2017
byte-accuracy red, green, blue channels) = 27 bytes. More likely 28 bytes as colours are probably stored as 32-bit integers, allowing for an unused alpha channel.
28 * 800,000 equals roughly 22 megabytes, which is way down from 9 gigabytes. That's a 400 fold memory overhead, which is pretty hefty.
Grasshopper stores points as instances of classes, so on 64-bit systems it actually takes 64+64+3*8 = 152 bytes per point*, which adds up to 122MB, still way less than 9GB. It would be interesting to know where all the memory goes...
* Grasshopper points also store reference data, in case they come from the Rhino document. This data will not exist, but even so it will require 64-bits of storage.…
Added by David Rutten at 4:13pm on December 11, 2014
6, 7, 8, 9, 10, 12, 14, 16, 18, 20, 22, 24, 26, 28, 30, etc
In addition to the components in the attached file, I have also tried using Cull Index but that did not do much. I tried using a number slider set to whole numbers with the range equal to the values I have set up in the integer, but it just increases the size by 1 every time. Any help on steps in the right direction would be great thanks.…