dont get you, i am saying sleect numbers in range 1 to 10, starting from 1 with a step of 2.
1 to 10 by 3 = 1 4 7 10
1 to 10 by 5 = 1 6
1 to 10 by 1 = 1 to 10 = 1 2 3 4 5 6 7 8 9 10
Added by Steve Lewis at 3:15pm on November 11, 2013
i mean, i want a slider that can do 3 sides, 4 sides, 5, 6, 7, 8, 9 and 10. for the grids because I dont want to use a fixed grid shape such as square grid (4 sides only).
Writing simulation parameters...3. [2 of 8] No context surfaces...4. [3 of 8] Writing geometry...5. unsupported operand type(s) for +: 'str' and 'list'6. Failed to write Pelle_aperture000 to idf file7. unsupported operand type(s) for +: 'str' and 'list'8. Failed to write Pelle_aperture001 to idf file9. unsupported operand type(s) for +: 'str' and 'list'10. Failed to write Pelle_aperture002 to idf file11. [4 of 8] Writing Electric Load Center - Generator specifications ...12. [5 of 8] Writing materials and constructions...13. [6 of 8] Writing schedules...14. [7 of 8] Writing loads and ideal air system...15. [8 of 8] Writing outputs...16. ...... idf file is successfully written to : C:\Users\Personal\Desktop\TESI\x001\THOR\EnergyPlus\THOR.idf17. 18. Set runEnergyPlus to True!
or this
0. Current document units is in Meters1. Conversion to Meters will be applied = 1.0002. [1 of 8] Writing simulation parameters...3. [2 of 8] No context surfaces...4. [3 of 8] Writing geometry...5. Runtime error (MissingMemberException): 'hb_EPFenSurface' object has no attribute 'blindsMaterial'6. Traceback:line 1567, in main, "<string>"line 2134, in script
i think that i've same problem with my windows...any suggestion???
Thanks for all…
en 3 of them, and one poolyline between two of them.
It would also be very nice if i could control it so that only the successive ones can be connected
so if {0:0:0} has 8 points and {0:0:1} has 8, as do {0:0:5} and {0:0:6} i would like to have this as two polylines, not one continoous that would in this case jump three branches (or curves that are shorter).
Does this make any sense?…
Added by Dusan Bosnjak at 2:08pm on September 28, 2009
nd this is the error text:
0. Current document units is in Meters1. Conversion to Meters will be applied = 1.0002. [1 of 8] Writing simulation parameters...3. [2 of 8] No context surfaces...4. [3 of 8] Writing geometry...5. [4 of 8] Writing Electric Load Center - Generator specifications ...6. [5 of 8] Writing materials and constructions...7. [6 of 8] Writing schedules...8. [7 of 8] Writing loads and ideal air system...9. [8 of 8] Writing outputs...10. ...... idf file is successfully written to : C:\Users\Pier\Desktop\Dottorato\Energy_plus_file\cell room\EnergyPlus\cell room.idf11. 12. Analysis is running!...13. C:\Users\Pier\Desktop\Dottorato\Energy_plus_file\cell room\EnergyPlus\eplusout.csv14. ......
Done! Read below for errors and warnings:
15.
Thanks in advance to all for your help me
Francesco…
e possible to change the component definition making possible to customize the number of outputs.Now Dispatch moves "true" values to A and "False" values to B
INPUT:
L (List to work on) -> 1, 2, 3, 4, 5, 6, 7, 8
D (Dispatch Pattern) -> True, False
OUTPUT:
A (List) -> 1, 3, 5, 7
B (List) -> 2, 4, 6, 8
Could it be possible/useful to modify it so it could dispatch items to several outputs, like:
INPUT:
L (List to work on) -> 1, 2, 3, 4, 5, 6, 7, 8, 9, 0
D (Dispatch Pattern) -> A, B, C
OUTPUT:
A (List) -> 1, 4, 7, 0
B (List) -> 2, 5, 8
C (List) -> 3, 6, 9
maybe I'm missing something and there's already a component with this function... I have been searching on the forum for half afternoon, but can't find anything about it!
Thank you!…