(18, 11, 0, 17), also put in the assembly component.
How can I know which value of the reaction forces correspond to which support?
In the manual is stated that when the reaction force component is used, than the values are displayed in ascending sequence of the corresponding nodes.So if I input the support nodes like thispoint with index 18point with index 11point with index 0point with index 17are the reaction forces displayed like this (per loadcase)?0 - reaction forces in point with index 01 - reaction forces in point with index 112 - reaction forces in point with index 183 - reaction forces in point with index 17
Thanks!
BestLara…
eas and references:
1. The Geometry of the Envoirnment, Lionel March and Philip Steadman, Chapeter 10 - 11
2. There is a good overview on Floorplan generation methodes under this link:
http://entwurfsforschung.de/layout/
3. Have a look @Space Syntax grasshopper plugin
4. The random approch / Infinit monkey theorem
https://vimeo.com/37186522
This has its limits 100+ rooms will not realy work...
5. A more obscure math approch -> spectral Graph matching
https://vimeo.com/136231619
And the paper to read:
http://www.sss10.bartlett.ucl.ac.uk/wp-content/uploads/2015/07/SSS1...
6. Shape grammers
https://en.wikipedia.org/wiki/Shape_grammar
enjoy....
…
ror "nighttime"
how could that be - must be in the weather file i assume - is there anyway to fix this ?
suncalc.net gives me the following
00:00—02:17 — night
02:17—03:43 — astronomical twilight03:43—04:39 — nautical twilight04:39—05:19 — civil twilight05:19—05:23 — sunrise05:23—21:11 — daylight21:11—21:15 — sunset21:15—21:55 — civil twilight21:55—22:51 — nautical twilight22:51—00:17 — astronomical twilight00:17—00:00 — night
plz help - thank you !!!
…
into new tree, so that branch {0} has points from branch {0} {1} {2} combined, branch {1} has points from {2} {3} {4}... as it shows in the atached image.
The main problem is that points need to overlap in the new tree.
Any suggestions?…
hat cross that one section?
What about the other 54 sections of the large surface?
Three of the ten vectors created from those lines go in opposite directions - so how useful is their average ('Avr')? Maybe that's why...
You want to subdivide ('SubSrf') this one section (of 55 total on the larger surface) and find the line segments (which become vectors) that cross each sub-section?
Is this correct so far?
By the way, in the second part of your code on the right, you are using 'VRot (Rotate a vector)' to rotate a line - that you created from a vector; probably could be simpler?…
be done easier, but later on the geometry will change and therefore this seems the better option. But coming back to the problem
First, there were some problems concerning the zone, although it seems solved still the “runenergysimulation” gives the following warning:
1. The simulation has not run correctly because of this severe error:
** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature
Do one of you know what went wrong? It probably will solve most of it.
Second, “set Zone Thresholds” gives the following warning:
1. Solution exception:global name 'maxHumidity_' is not defined
However, the component is missing the max humidity input on the list, has this to do something with the error?
All the components are up to date.
I hope it will be an easy fix.
Gr Lars
“set Zone Thresholds” runtime error
{0;0;0}0. Runtime error (UnboundNameException): global name 'maxHumidity_' is not defined1. Traceback: line 80, in checkTheInputs, "<string>" line 282, in script
"runenergysimulation” report
{0;0}0. Current document units is in Meters1. Conversion to Meters will be applied = 1.0002. TypeError('Waarde kan niet null zijn.\r\nParameternaam: source',)3. Failed to copy the object. Returning the original objects...This can cause strange behaviour!4. [1 of 8] Writing simulation parameters...5. [2 of 8] No context surfaces...6. [3 of 8] Writing geometry...7. [4 of 8] Writing Electric Load Center - Generator specifications ...8. [5 of 8] Writing materials and constructions...9. [6 of 8] Writing schedules...10. [7 of 8] Writing loads and ideal air system...11. [8 of 8] Writing outputs...12. ...... idf file is successfully written to : c:\ladybug\unnamed\EnergyPlus\unnamed.idf13. 14. Analysis is running!...15. c:\ladybug\unnamed\EnergyPlus\eplusout.csv16. ......
Done! Read below for errors and warnings:
17. 18. Program Version,EnergyPlus, Version 8.3.0-6d97d074ea, YMD=2016.03.02 20:55,IDD_Version 8.3.019. 20. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.21. 22. ************* Beginning Zone Sizing Calculations23. 24. ** Warning ** GetInternalHeatGains: People="CLASSROOMOFFICEPEOPLE", Activity Level Schedule Name values25. 26. ** ~~~ ** fall outside typical range [70,1000] W/person for Thermal Comfort Reporting.27. 28. ** ~~~ ** Odd comfort values may result; Schedule="SCHOCCUPANCYSCHEDULE".29. 30. ** ~~~ ** Entered min/max range=[0.0,1.0] W/person.31. 32. ** Warning ** Calculated design heating load for zone=CLASSROOM is zero.33. 34. ** ~~~ ** Check Sizing:Zone and ZoneControl:Thermostat inputs.35. 36. ** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature37. 38. ** ~~~ ** ...check zone thermostat set point and design supply air temperatures39. 40. ** ~~~ ** ...zone name = CLASSROOM41. 42. ** ~~~ ** ...design sensible cooling load = 25499.10 W43. 44. ** ~~~ ** ...thermostat set point temp = 0.000 C45. 46. ** ~~~ ** ...zone temperature = 15.334 C47. 48. ** ~~~ ** ...supply air temperature = 15.000 C49. 50. ** ~~~ ** ...temperature difference = -0.33433 C51. 52. ** ~~~ ** ...calculated volume flow rate = 197273.21341 m3/s53. 54. ** ~~~ ** ...calculated mass flow rate = 237634.19357 kg/s55. 56. ** Warning ** ManageSizing: For a plant sizing run, there must be at least 1 Sizing:Plant object input. SimulationControl Plant Sizing option ignored.57. 58. ************* Testing Individual Branch Integrity59. 60. ************* All Branches passed integrity testing61. 62. ************* Testing Individual Supply Air Path Integrity63. 64. ************* All Supply Air Paths passed integrity testing65. 66. ************* Testing Individual Return Air Path Integrity67. 68. ************* All Return Air Paths passed integrity testing69. 70. ************* No node connection errors were found.71. 72. ************* Beginning Simulation73. 74. ************* Simulation Error Summary *************75. 76. ** Warning ** The following Report Variables were requested but not generated77. 78. ** ~~~ ** because IDF did not contain these elements or misspelled variable name -- check .rdd file79. 80. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL COOLING ENERGY, Frequency=Hourly81. 82. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL HEATING ENERGY, Frequency=Hourly83. 84. ************* Key=*, VarName=CHILLER ELECTRIC ENERGY, Frequency=Hourly85. 86. ************* Key=*, VarName=BOILER HEATING ENERGY, Frequency=Hourly87. 88. ************* Key=*, VarName=FAN ELECTRIC ENERGY, Frequency=Hourly89. 90. ************* Key=*, VarName=ZONE VENTILATION FAN ELECTRIC ENERGY, Frequency=Hourly91. 92. ************* Key=*, VarName=EARTH TUBE FAN ELECTRIC ENERGY, Frequency=Hourly93. 94. ************* Key=*, VarName=PUMP ELECTRIC ENERGY, Frequency=Hourly95. 96. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT LOSS ENERGY, Frequency=Hourly97. 98. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT GAIN ENERGY, Frequency=Hourly99. 100. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE COOLING ENERGY, Frequency=Hourly101. 102. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE HEATING ENERGY, Frequency=Hourly103. 104. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.105. 106. ************* EnergyPlus Sizing Error Summary. During Sizing: 3 Warning; 1 Severe Errors.107. 108. ************* EnergyPlus Completed Successfully-- 5 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 4.65sec109.…
nother nurbs surface that is built from control points extracted from the other two (3 three rows of control points shown in the picture are the ones I would like to use).
When I try to use the "Surface from Points" component, however, I cannot get the surface to generate properly. From my understanding of previous discussions on this forum, the U parameter should be U+1 which in my case would be 11. No parameter from 0-11 is producing the results I'm looking for, however.
My attempted solution is attached. I get the feeling the solution will be quite straightforward...
Thanks,
Austin
…
ells new products like the Firefly Interactive Prototyping Shield which mounts on top of your Arduino Uno and provides access to a number of useful input (ie. sensors) and output (ie. motors) devices. It includes features like:
Three linear slide potentiometers connected to analog pins 0, 1, and 2
Two-axis joystick connected to analog pins 3 and 4
Light sensor (photocell) connected to analog pin 5
Three push buttons connected to digital pins 2, 4, and 7
Red LED connected to digital pin 13
RGB LED connected to digital pins 3, 5, and 6
Two servo connections on digital pins 8 and 9
A connection to the Easy Stepper Driver (co-designed by Sparkfun Electronics and Brian Schmalz) to control stepper motors. The direction of the motor is controlled through digital pin 10 and the number of steps through digital pin 12
High-voltage MOSFET circuit capable of driving lights, valves, DC motors, solenoids, or anything else requiring higher voltage or current. The gate of the MOSFET is connected to digital pin 11 (PWM).
Some come take a look and let us know what you think!
…