ceros. Parametrización, panelización y análisis en Grasshopper, así como el proceso de manufactura digital para maquinaria de corte Láser y CNC.
UN solo pago anticipado $4,000.00
Pagos diferidos $4,500.00*
*reserva tu lugar con el 50%
Martes y Jueves de 7 a 10 PM
Del 15 de Mayo al 14 de junio
DURACION: 30 HORAS
SESIONES: 10 DE 3 HORAS
o info@dimensiontallerdigital.com
informes al 55 (50 16 0634) con Mayri Gallegos (o al cel. 55 28 85 24 73)
$4,000.00…
he installation folder, Drag & drop SYNTACTIC(green one) over your grasshopper canvas.3. Close your rhino and reopen it. 4. Type GrasshopperDeveloperSettings5. Tick the Memory load *.GHA assemblies using COFF byte arrays option6. Run grasshopper and enjoy plugin…
eone would know how to group each data position from each branch ... meaning, for instance, that I have a list of data with 3 branches, each branch containing 28 data instances (see attached image). Now, how would I get the (0;0)+(1;0)+(2;0) to be grouped in a new branch, as well as (0;1)+(1;1)+(2;1) and so on?
Also, I need for the setup to able to take in variables, so that the 3 branches might change to 6, and the 28 data instances might to change to anything between 10 and 100.
Thanks in advance,
/Claus
…
o retrieve the first one: (0;0), (0;1) ... (0;4), I put 0 in Path and the TreeBranch turns red. What am I doing wrong?
I would really appreciate some help!
Thankyou!…
Added by Tina Jerrera at 8:09am on November 25, 2016
.components as ghimport karamba
I have copied all the folder named '64bit' in grasshopper library folder (items are not in a sub-folder). The karamba.py gives me back an in-script error, i.e.
Runtime error (ImportException): No module named _karambaTraceback:line 20, in swig_import_helper, "C:\Users\Claudio\AppData\Roaming\Grasshopper\Libraries\karamba.py"line 28, in <module>, "C:\Users\Claudio\AppData\Roaming\Grasshopper\Libraries\karamba.py"line 2, in script
Just wondering if I could have an help about this. I tried the IronPython example, but it keeps saying that the karamba.gha does not exist in my plugin folder (but it's there). This occurs on line 3 of your example on the operation clr.AddReferenceToFileAndPath(*the path it finds*)
Many thanks
Claudio…
NONE, in SIZING:PARAMETERS". I'm not sure of where to start in troubleshooting this. I've attached the file.
Thank you,
See the errors and warnings below:
{0;0;0}
0. Current document units is in Meters
1. Conversion to Meters will be applied = 1.000
2. [1 of 8] Writing simulation parameters...
3. [2 of 8] Writing context surfaces...
4. [2 of 8] Writing context surfaces...
5. [3 of 8] Writing geometry...
6. [4 of 8] Writing Electric Load Center - Generator specifications ...
7. [5 of 8] Writing materials and constructions...
8. [6 of 8] Writing schedules...
9. [7 of 8] Writing loads and ideal air system...
10. [8 of 8] Writing outputs...
11. ...
... idf file is successfully written to : R:\Green\SuRG\Building_Performance_Analysis\2016_analysis_studies\Energy_Analysis_Comparison\Honeybee_+_Ladybug\tutorial01\EnergyPlus\tutorial01.idf
12.
13. Analysis is running!...
14. ...
...
Done! Read below for errors and warnings:
15.
16. Program Version,EnergyPlus, Version 8.5.0-c87e61b44b, YMD=2016.10.31 11:39,IDD_Version 8.5.0
17.
18. ************* IDF Context for following error/warning message:
19.
20. ************* Note -- lines truncated at 300 characters, if necessary...
21.
22. ************* 24 Sizing:Parameters,
23.
24. ************* Only last 1 lines before error line shown.....
25.
26. ************* 25 None, !- Heating Sizing Factor
27.
28. ** Severe ** IP: IDF line~25 Invalid Number in Numeric Field#1 (Heating Sizing Factor), value=NONE, in SIZING:PARAMETERS
29.
30. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.
31.
32. ** ~~~ ** Possible Invalid Numerics or other problems
33.
34. ** Fatal ** IP: Errors occurred on processing IDF file. Preceding condition(s) cause termination.
35.
36. ...Summary of Errors that led to program termination:
37.
38. ..... Reference severe error count=1
39.
40. ..... Last severe error=IP: IDF line~
, value=NONE, in SIZING:PARAMETERS
41.
42. ************* Warning: Node connection errors not checked - most system input has not been read (see previous warning).
43.
44. ************* Fatal error -- final processing. Program exited before simulations began. See previous error messages.
45.
46. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.
47.
48. ************* EnergyPlus Sizing Error Summary. During Sizing: 0 Warning; 0 Severe Errors.
49.
50. ************* EnergyPlus Terminated--Fatal Error Detected. 1 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 9.34sec
51.…
heating? Or cooling?)
What if you have 20C? You need to heat to 24-26?
What if you have 28? Then you cool to 24-26?
Something is missing here ...
Or am i wrong? (In this case i don't understand the logic).
Besides that, you are simulating 3 zones instead of 1. Your conncetions of all the HB_setEPZoneSchedules to the HB_setEPIdealAir is causing this. Messy ... a little bit.
-A.…
this common installation problem please find a tested remedy shared by one of the group members:
Comment by Iman Sheikhansari on August 26, 2019 at 8:33amDelete Comment
HiIf you are encountering a problem with rhino 6 versions don't worryFollow these steps.1. Download SYNTACTIC from https://sites.google.com/site/pirouznourian/syntactic-design2. Install it and go to the installation folder, Drag & drop SYNTACTIC(green one) over your grasshopper canvas.3. Close your rhino and reopen it. 4. Type GrasshopperDeveloperSettings5. Tick the Memory load *.GHA assemblies using COFF byte arrays option6. Run grasshopper and enjoy plugin
I hope this helps,
Best regards,
Pirouz
…